{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T19:54:02Z","timestamp":1790452442982,"version":"4.1.0"},"reference-count":40,"publisher":"F1000 Research Ltd","license":[{"start":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T00:00:00Z","timestamp":1713139200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["f1000research.com"],"crossmark-restriction":false},"short-container-title":["F1000Res"],"abstract":"<ns3:p>Background The most recent advances in Computed Tomography (CT) image reconstruction technology are Deep learning image reconstruction (DLIR) algorithms. Due to drawbacks in Iterative reconstruction (IR) techniques such as negative image texture and nonlinear spatial resolutions, DLIRs are gradually replacing them. However, the potential use of DLIR in Head and Chest CT has to be examined further. Hence, the purpose of the study is to review the influence of DLIR on Radiation dose (RD), Image noise (IN), and outcomes of the studies compared with IR and FBP in Head and Chest CT examinations. Methods We performed a detailed search in PubMed, Scopus, Web of Science, Cochrane Library, and Embase to find the articles reported using DLIR for Head and Chest CT examinations between 2017 to 2023. Data were retrieved from the short-listed studies using Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. Results Out of 196 articles searched, 15 articles were included. A total of 1292 sample size was included. 14 articles were rated as high and 1 article as moderate quality. All studies compared DLIR to IR techniques. 5 studies compared DLIR with IR and FBP. The review showed that DLIR improved IQ, and reduced RD and IN for CT Head and Chest examinations. Conclusions DLIR algorithm have demonstrated a noted enhancement in IQ with reduced IN for CT Head and Chest examinations at lower dose compared with IR and FBP. DLIR showed potential for enhancing patient care by reducing radiation risks and increasing diagnostic accuracy.<\/ns3:p>","DOI":"10.12688\/f1000research.147345.1","type":"journal-article","created":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T05:45:05Z","timestamp":1713159905000},"page":"274","update-policy":"https:\/\/doi.org\/10.12688\/f1000research.crossmark-policy","source":"Crossref","is-referenced-by-count":20,"title":["Influence of deep learning image reconstruction algorithm for reducing radiation dose and image noise compared to iterative reconstruction and filtered back projection for head and chest computed tomography examinations: a systematic review"],"prefix":"10.12688","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5515-6377","authenticated-orcid":false,"given":"Obhuli","family":"Chandran M","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7933-1192","authenticated-orcid":false,"given":"Saikiran","family":"Pendem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7201-5733","authenticated-orcid":false,"given":"Priya","family":"P S","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cijo","family":"Chacko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9792-6242","authenticated-orcid":false,"given":"Priyanka","family":"-","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3486-8740","authenticated-orcid":false,"given":"Rajagopal","family":"Kadavigere","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2560","published-online":{"date-parts":[[2024,4,15]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"2400-2409","DOI":"10.1001\/jama.2012.5960","article-title":"Use of Diagnostic Imaging Studies and Associated Radiation Exposure for Patients Enrolled in Large Integrated Health Care Systems, 1996-2010.","volume":"307","author":"R Smith-Bindman","year":"2012","journal-title":"JAMA."},{"key":"ref2","doi-asserted-by":"publisher","first-page":"2308-2318","DOI":"10.1007\/s00330-017-5225-x","article-title":"Computed tomography use in a large Italian region: trend analysis 2004-2014 of emergency and outpatient CT examinations in children and adults.","volume":"28","author":"A Pola","year":"2018","journal-title":"Eur. Radiol."},{"key":"ref3","doi-asserted-by":"publisher","first-page":"254-263","DOI":"10.1148\/radiol.2481071451","article-title":"Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog1.","volume":"248","author":"F Mettler","year":"2008","journal-title":"Radiology."},{"key":"ref4","doi-asserted-by":"publisher","first-page":"7918-7937","DOI":"10.26355\/eurrev_202211_30144","article-title":"Technological advances in body CT: a primer for beginners.","volume":"26","author":"A Agostini","year":"2022","journal-title":"Eur. Rev. Med. Pharmacol. Sci."},{"key":"ref5","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1186\/s12885-022-10310-2","article-title":"CT Scans and Cancer Risks: A Systematic Review and Dose-response Meta-analysis.","volume":"22","author":"C Cao","year":"2022","journal-title":"BMC Cancer."},{"key":"ref6","doi-asserted-by":"publisher","first-page":"k4931","DOI":"10.1136\/bmj.k4931","article-title":"International variation in radiation dose for computed tomography examinations: prospective cohort study.","volume":"364","author":"R Smith-Bindman","year":"2019","journal-title":"BMJ."},{"key":"ref7","doi-asserted-by":"publisher","first-page":"285-296","DOI":"10.1120\/jacmp.v16i3.5360","article-title":"Effect of radiation dose reduction on image quality in adult head CT with noise-suppressing reconstruction system with a 256 slice MDCT.","volume":"16","author":"O Baskan","year":"2015","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"ref8","doi-asserted-by":"publisher","first-page":"1953-1961","DOI":"10.1016\/j.ejrad.2014.06.033","article-title":"Radiation dose reduction in chest CT-Review of available options.","volume":"83","author":"T Kubo","year":"2014","journal-title":"Eur. J. Radiol."},{"key":"ref9","doi-asserted-by":"publisher","first-page":"2185-2195","DOI":"10.1007\/s00330-018-5810-7","article-title":"The evolution of image reconstruction for CT-from filtered back projection to artificial intelligence.","volume":"29","author":"M Willemink","year":"2019","journal-title":"Eur. Radiol."},{"key":"ref10","doi-asserted-by":"publisher","first-page":"1623-1631","DOI":"10.1007\/s00330-012-2765-y","article-title":"Iterative reconstruction techniques for computed tomography Part 1: Technical principles.","volume":"23","author":"M Willemink","year":"2013","journal-title":"Eur. Radiol."},{"key":"ref11","doi-asserted-by":"publisher","first-page":"1632-1642","DOI":"10.1007\/s00330-012-2764-z","article-title":"Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality.","volume":"23","author":"M Willemink","year":"2013","journal-title":"Eur. Radiol."},{"key":"ref12","doi-asserted-by":"publisher","first-page":"764-771","DOI":"10.2214\/AJR.09.2397","article-title":"Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study.","volume":"193","author":"A Hara","year":"2009","journal-title":"Am. J. Roentgenol."},{"key":"ref13","doi-asserted-by":"publisher","first-page":"339-357","DOI":"10.1148\/radiol.2015132766","article-title":"State of the Art: Iterative CT Reconstruction Techniques.","volume":"276","author":"L Geyer","year":"2015","journal-title":"Radiology."},{"key":"ref14","doi-asserted-by":"publisher","first-page":"798-805","DOI":"10.1007\/s00330-019-06423-1","article-title":"Low-dose CT angiography using ASiR-V for potential living renal donors: a prospective analysis of image quality and diagnostic accuracy.","volume":"30","author":"W Han","year":"2020","journal-title":"Eur. Radiol."},{"key":"ref15","doi-asserted-by":"publisher","first-page":"169-177","DOI":"10.1007\/s10140-018-1658-z","article-title":"Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study.","volume":"26","author":"F Moloney","year":"2019","journal-title":"Emerg. Radiol."},{"key":"ref16","doi-asserted-by":"publisher","first-page":"147-154","DOI":"10.1016\/j.ejrad.2018.10.025","article-title":"Basics of iterative reconstruction methods in computed tomography: A vendor-independent overview.","volume":"109","author":"W Stiller","year":"2018","journal-title":"Eur. J. Radiol."},{"key":"ref17","doi-asserted-by":"publisher","first-page":"124-133","DOI":"10.1148\/radiol.2015141260","article-title":"Evaluation of Low-Contrast Detectability of Iterative Reconstruction across Multiple Institutions, CT Scanner Manufacturers, and Radiation Exposure Levels.","volume":"277","author":"G Saiprasad","year":"2015","journal-title":"Radiology."},{"key":"ref18","doi-asserted-by":"publisher","first-page":"735-745","DOI":"10.1148\/radiol.15142005","article-title":"Diagnostic Performance of an Advanced Modeled Iterative Reconstruction Algorithm for Low-Contrast Detectability with a Third-Generation Dual-Source Multidetector CT Scanner: Potential for Radiation Dose Reduction in a Multireader Study.","volume":"275","author":"J Solomon","year":"2015","journal-title":"Radiology."},{"key":"ref19","doi-asserted-by":"publisher","first-page":"671-677","DOI":"10.1016\/j.jmir.2020.09.001","article-title":"The use of artificial intelligence in computed tomography image reconstruction - A literature review.","volume":"51","author":"Z Zhang","year":"2020","journal-title":"J. Med. Imaging Radiat. Sci."},{"key":"ref20","doi-asserted-by":"publisher","first-page":"e221257","DOI":"10.1148\/radiol.221257","article-title":"Deep Learning Image Reconstruction for CT: Technical Principles and Clinical Prospects.","volume":"306","author":"L Koetzier","year":"2023","journal-title":"Radiology."},{"key":"ref21","first-page":"101-115","article-title":"A Review of Deep Learning CT Reconstruction: Concepts, Limitations, and Promise in Clinical Practice.","volume":"10","author":"P Timothy","year":"2022","journal-title":"Curr. Radiol. Rep."},{"key":"ref22","doi-asserted-by":"publisher","first-page":"50-57","DOI":"10.2214\/AJR.19.22332","article-title":"Image quality assessment of abdominal CT by use of new deep learning image reconstruction: Initial experience.","volume":"215","author":"C Jensen","year":"2020","journal-title":"Am. J. Roentgenol."},{"key":"ref23","doi-asserted-by":"publisher","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews.","volume":"372","author":"M Page","year":"2021","journal-title":"BMJ."},{"key":"ref24","doi-asserted-by":"publisher","first-page":"2921-2929","DOI":"10.1007\/s00330-021-08438-z","article-title":"The effect of deep learning reconstruction on abdominal CT densitometry and image quality: a systematic review and meta-analysis.","volume":"32","author":"J Abel van Stiphout","year":"2022","journal-title":"Eur. Radiol."},{"key":"ref25","doi-asserted-by":"publisher","first-page":"339-352","DOI":"10.1007\/s10140-021-02012-2","article-title":"Deep learning versus iterative image reconstruction algorithm for head CT in trauma.","volume":"29","author":"Z Alagic","year":"2022","journal-title":"Emerg. Radiol."},{"key":"ref26","doi-asserted-by":"publisher","first-page":"905-912","DOI":"10.1007\/s00234-020-02574-x","article-title":"Deep learning-based image reconstruction for brain CT: improved image quality compared with adaptive statistical iterative reconstruction-Veo (ASIR-V).","volume":"63","author":"I Kim","year":"2021","journal-title":"Neuroradiology."},{"key":"ref27","doi-asserted-by":"publisher","first-page":"3253-3265","DOI":"10.1007\/s00330-023-09559-3","article-title":"Deep learning-based reconstruction can improve the image quality of low radiation dose head CT.","volume":"33","author":"Y Nagayama","year":"2023","journal-title":"Eur. Radiol."},{"key":"ref28","doi-asserted-by":"publisher","first-page":"5498-5506","DOI":"10.1007\/s00330-020-07668-x","article-title":"Deep learning\u2013based reconstruction may improve non-contrast cerebral CT imaging compared to other current reconstruction algorithms.","volume":"31","author":"L Oostveen","year":"2021","journal-title":"Eur. Radiol."},{"key":"ref29","first-page":"1-9","article-title":"Application of a deep learning image reconstruction (DLIR) algorithm in head CT imaging for children to improve image quality and lesion detection.","volume":"21","author":"J Sun","year":"2021","journal-title":"BMC Med. Imaging."},{"key":"ref30","doi-asserted-by":"publisher","first-page":"110338","DOI":"10.1016\/j.ejrad.2022.110338","article-title":"Pulmonary emphysema quantification at low dose chest CT using Deep Learning image reconstruction.","volume":"152","author":"F Ferri","year":"2022","journal-title":"Eur. J. Radiol."},{"key":"ref31","doi-asserted-by":"publisher","first-page":"202-212","DOI":"10.1148\/radiol.210551","article-title":"Deep Learning Reconstruction Shows Better Lung Nodule Detection for Ultra\u2013Low-Dose Chest CT.","volume":"303","author":"B Jiang","year":"2022","journal-title":"Radiology."},{"key":"ref32","doi-asserted-by":"publisher","first-page":"2560","DOI":"10.3390\/diagnostics12102560","article-title":"The Value of Deep Learning Image Reconstruction in Improving the Quality of Low-Dose Chest CT Images.","volume":"12","author":"J Jiang","year":"2022","journal-title":"Diagnostics (Basel)."},{"key":"ref33","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1186\/s12880-023-01081-8","article-title":"75% radiation dose reduction using deep learning reconstruction on low-dose chest CT.","volume":"23","author":"G Jo","year":"2023 Sep 11","journal-title":"BMC Med. Imaging."},{"key":"ref34","doi-asserted-by":"publisher","first-page":"131-138","DOI":"10.3348\/kjr.2020.0116","article-title":"Validation of deep-learning image reconstruction for low-dose chest computed tomography scan: Emphasis on image quality and noise.","volume":"22","author":"J Kim","year":"2021","journal-title":"Korean J. Radiol."},{"key":"ref35","doi-asserted-by":"publisher","first-page":"e0291745","DOI":"10.1371\/journal.pone.0291745","article-title":"The impact of deep learning reconstruction in low dose computed tomography on the evaluation of interstitial lung disease.","volume":"18","author":"C Kim","year":"2023","journal-title":"PLoS One."},{"key":"ref36","doi-asserted-by":"publisher","first-page":"e13796","DOI":"10.1002\/acm2.13796","article-title":"Image quality improvement in low-dose chest CT with deep learning image reconstruction.","volume":"23","author":"Q Tian","year":"2022","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20210380","article-title":"Application of deep learning image reconstruction in low-dose chest CT scan.","volume":"95","author":"H Wang","year":"2022","journal-title":"Br. J. Radiol."},{"key":"ref38","doi-asserted-by":"publisher","first-page":"1053-1064","DOI":"10.1007\/s00330-023-10087-3","article-title":"Value of deep learning reconstruction of chest low-dose CT for image quality improvement and lung parenchyma assessment on lung window.","volume":"34","author":"J Wang","year":"2023","journal-title":"Eur. Radiol."},{"key":"ref39","doi-asserted-by":"publisher","first-page":"8140-8151","DOI":"10.1007\/s00330-022-08870-9","article-title":"Can deep learning improve image quality of low-dose CT: a prospective study in interstitial lung disease.","volume":"32","author":"R Zhao","year":"2022","journal-title":"Eur. Radiol."},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.6084\/m9.figshare.25404226.v3","author":"R Kadavigere","year":"2024","journal-title":"figshare."}],"container-title":["F1000Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/f1000research.com\/articles\/13-274\/v1\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/f1000research.com\/articles\/13-274\/v1\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/f1000research.com\/articles\/13-274\/v1\/iparadigms","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,8]],"date-time":"2024-05-08T08:35:17Z","timestamp":1715157317000},"score":1,"resource":{"primary":{"URL":"https:\/\/f1000research.com\/articles\/13-274\/v1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,15]]},"references-count":40,"URL":"https:\/\/doi.org\/10.12688\/f1000research.147345.1","relation":{"has-review":[{"id-type":"doi","id":"10.5256\/f1000research.161532.r268955","asserted-by":"subject"},{"id-type":"doi","id":"10.5256\/f1000research.161532.r268958","asserted-by":"subject"},{"id-type":"doi","id":"10.5256\/f1000research.161532.r268955","asserted-by":"object"},{"id-type":"doi","id":"10.5256\/f1000research.161532.r268965","asserted-by":"object"},{"id-type":"doi","id":"10.5256\/f1000research.161532.r268959","asserted-by":"object"},{"id-type":"doi","id":"10.5256\/f1000research.161532.r268958","asserted-by":"object"}]},"ISSN":["2046-1402"],"issn-type":[{"value":"2046-1402","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,15]]},"assertion":[{"value":"Indexed","URL":"https:\/\/f1000research.com\/articles\/13-274\/v1#article-reports","order":0,"name":"referee-status","label":"Referee status","group":{"name":"current-referee-status","label":"Current Referee Status"}},{"value":"10.5256\/f1000research.161532.r268958, Shashi Kumar Shetty, NITTE university, Karnataka, 30 Apr 2024, version 1, indexed","URL":"https:\/\/f1000research.com\/articles\/13-274\/v1#referee-response-268958","order":0,"name":"referee-response-268958","label":"Referee Report","group":{"name":"article-reports","label":"Article Reports"}},{"value":"10.5256\/f1000research.161532.r268955, Dr. Tamijeselvan S, College of MRIT, Mother Teresa Postgraduate and Research institute of Health sciences, Indira Nagar, Puducherry, 08 May 2024, version 1, indexed","URL":"https:\/\/f1000research.com\/articles\/13-274\/v1#referee-response-268955","order":1,"name":"referee-response-268955","label":"Referee Report","group":{"name":"article-reports","label":"Article Reports"}},{"value":"The author(s) declared that no grants were involved in supporting this work","order":2,"name":"grant-information","label":"Grant Information"},{"value":"This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.","order":0,"name":"copyright-info","label":"Copyright"}]}}