{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T12:32:08Z","timestamp":1777984328306,"version":"3.51.4"},"update-to":[{"DOI":"10.12688\/f1000research.171062.1","type":"new_version","label":"New version","source":"publisher","updated":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T00:00:00Z","timestamp":1764374400000}}],"reference-count":32,"publisher":"F1000 Research Ltd","license":[{"start":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T00:00:00Z","timestamp":1764374400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["f1000research.com"],"crossmark-restriction":false},"short-container-title":["F1000Res"],"abstract":"<ns3:p>Background Cerebral computed tomography angiography (CTA) is widely used to assess neurovascular disorders, but venous contamination often obscures arteries. Optimizing bolus-tracking thresholds is crucial, yet patient factors influencing contrast dynamics and the value of radiation dose indices in head CTA remain unclear. Objectives To optimize bolus-tracking thresholds in cerebral CTA by examining patient-related influences on enhancement and radiation metrics. Methods 126 adults undergoing cerebral CTA were evaluated in this prospective study. Demographics, physiologic parameters, peak enhancement time (PET), peak enhancement attenuation (PEA), and dose indices (CTDIvol, SSDE) were recorded. Linear regression identified predictors of enhancement. Two blinded radiologists graded venous contamination. ROC analysis, including age subgroups, determined the optimal HU threshold. Results Median age was 55.5 years; 70% were male. PET rose with age (+0.086 s\/year, p &lt; 0.001) and was shorter in females (\u20132.39 s, p = 0.003). PEA increased with threshold (+1.03 HU\/unit, p &lt; 0.001). Arterial enhancement was higher in females (+40.7 HU, p &lt; 0.001) and patients \u226560 years (+70 HU, p &lt; 0.001). Venous enhancement correlated with PET (p = 0.023) and systolic pressure (p = 0.002). ROC analysis showed an optimal threshold of 105 \u00b1 5 HU (AUC = 0.634; sensitivity 88.4%, specificity 77.1%). CTDIvol, but not SSDE, correlated with weight (p = 0.015). Conclusion Intrinsic (age, gender) and extrinsic (threshold) factors shape CTA enhancement. A 105 \u00b1 5 HU threshold reduces venous contamination, especially in younger patients. CTDIvol remains the preferred dose index. Findings support individualized, resource-efficient CTA protocols aligned with UN SDGs 3, 9, and 12.<\/ns3:p>","DOI":"10.12688\/f1000research.171062.2","type":"journal-article","created":{"date-parts":[[2025,11,29]],"date-time":"2025-11-29T05:05:06Z","timestamp":1764392706000},"page":"1219","update-policy":"https:\/\/doi.org\/10.12688\/f1000research.crossmark-policy","source":"Crossref","is-referenced-by-count":0,"title":["Optimization of Bolus-Tracking Thresholds levels in Cerebral CT Angiography: Influence of Patient Characteristics on contrast enhancement dynamics and radiation dose metrics"],"prefix":"10.12688","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-1450-3921","authenticated-orcid":false,"given":"Ashwin","family":"Prabhu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2910-5338","authenticated-orcid":false,"given":"Abhimanyu","family":"Pradhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2860-5100","authenticated-orcid":false,"given":"Sharath","family":"S","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3486-8740","authenticated-orcid":false,"given":"Rajagopal","family":"Kadavigere","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5963-3230","authenticated-orcid":false,"given":"Winniecia","family":"Dkhar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7201-5733","authenticated-orcid":false,"given":"Priya","family":"P S","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9345-9790","authenticated-orcid":false,"given":"Suresh","family":"Sukumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-5850-3217","authenticated-orcid":false,"given":"Pulagam Vamsidhar","family":"Reddy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neil","family":"Abraham Barnes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2560","published-online":{"date-parts":[[2025,11,29]]},"reference":[{"key":"ref1","doi-asserted-by":"publisher","first-page":"663-669","DOI":"10.3171\/jns.1998.88.4.0663","article-title":"Computerized tomography angiography of ruptured cerebral aneurysms: factors affecting time to maximum contrast concentration.","volume":"88","author":"Y Nakajima","year":"1998","journal-title":"J. Neurosurg."},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/01.RCT.0000029051.35986.3F","article-title":"Parameters Affecting Bolus Geometry in CTA: A Review.","author":"F Cademartiri","year":"2002"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"S27-S38","DOI":"10.1259\/bjr\/25652856","article-title":"Multislice CT angiography: A practical guide to CT angiography in vascular imaging and intervention.","volume":"77","author":"V Duddalwar","year":"2004","journal-title":"Br. J. Radiol."},{"key":"ref4","doi-asserted-by":"publisher","first-page":"73-76","DOI":"10.1177\/1358863X16681666","article-title":"Advanced vascular imaging.","volume":"22","author":"M Weinreich","year":"2017","journal-title":"Vascular Medicine (United Kingdom)."},{"key":"ref5","doi-asserted-by":"publisher","first-page":"215-236","DOI":"10.1007\/s13244-018-0597-2","article-title":"Vascular CT and MRI: a practical guide to imaging protocols.","volume":"9","author":"D Murphy","year":"2018","journal-title":"Insights Imaging."},{"key":"ref6","doi-asserted-by":"publisher","first-page":"671-691","DOI":"10.1016\/j.rcl.2020.02.011","article-title":"Updates in Vascular Computed Tomography.","volume":"58","author":"P Rajiah","year":"2020","journal-title":"Radiol. Clin. North Am."},{"key":"ref7","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1259\/bjr.20160634","article-title":"Optimal scan timing for artery-vein separation at whole-brain CT angiography using a 320-row MDCT volume scanner.","volume":"90","author":"T Shirasaka","year":"2017","journal-title":"Br. J. Radiol."},{"key":"ref8","doi-asserted-by":"publisher","first-page":"32-61","DOI":"10.1148\/radiol.10090908","article-title":"Intravenous contrast medium administration and scan timing at CT: Considerations and approaches.","volume":"256","author":"K Bae","year":"2010","journal-title":"Radiology."},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1196-1201","DOI":"10.1292\/jvms.20-0724","article-title":"Optimal placement of the region of interest for bolus tracking on brain computed tomography angiography in beagle dogs.","volume":"83","author":"S Park","year":"2021","journal-title":"J. Vet. Med. Sci."},{"key":"ref10","doi-asserted-by":"publisher","first-page":"557-566","DOI":"10.1161\/01.cir.12.4.557","article-title":"Changes in cardiac output with age.","volume":"12","author":"M Brandfonbrener","year":"1955","journal-title":"Circulation."},{"key":"ref11","doi-asserted-by":"publisher","first-page":"377-387","DOI":"10.1620\/tjem.128.377","article-title":"Normal cardiac output in relation to age and body size.","volume":"128","author":"R Katori","year":"1979","journal-title":"Tohoku J. Exp. Med."},{"key":"ref12","doi-asserted-by":"publisher","first-page":"37-43","DOI":"10.1051\/radiopro\/2024033","article-title":"Relationship between radiation dose indices and patient size in adult brain computed tomography.","volume":"60","author":"K Mitsui","year":"2025","journal-title":"Radioprotection."},{"key":"ref13","doi-asserted-by":"publisher","first-page":"12","DOI":"10.3390\/diagnostics12112853","article-title":"Reduction in Radiation Exposure of CT Perfusion by Optimized Imaging Timing Using Temporal Information of the Preceding CT Angiography of the Carotid Artery in the Stroke Protocol.","volume":"12","author":"Z Deak","year":"2022","journal-title":"Diagnostics."},{"key":"ref14","doi-asserted-by":"publisher","first-page":"14","DOI":"10.3390\/diagnostics14242866","article-title":"Optimizing Radiation Dose and Image Quality in Stroke CT Protocols: Proposed Diagnostic Reference Levels for Multiphase CT Angiography and Perfusion Imaging.","volume":"14","author":"R Forbrig","year":"2024","journal-title":"Diagnostics."},{"key":"ref15","doi-asserted-by":"publisher","first-page":"109694","DOI":"10.1016\/j.radphyschem.2021.109694","article-title":"Radiation doses and size-specific dose estimate from CT brain examinations according to head sizes in a tertiary hospital in Malaysia.","volume":"189","author":"Z Kayun","year":"2021","journal-title":"Radiat. Phys. Chem."},{"key":"ref16","doi-asserted-by":"publisher","first-page":"657-662","DOI":"10.1148\/radiology.207.3.9609887","article-title":"Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model.","volume":"207","author":"K Bae","year":"1998","journal-title":"Radiology."},{"key":"ref17","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1007\/s40520-025-02981-1","article-title":"The sex-specific difference in age-related aortic regional morphological changes.","volume":"37","author":"Z Meng","year":"2025","journal-title":"Aging Clin. Exp. Res."},{"key":"ref18","doi-asserted-by":"publisher","first-page":"1637-1646","DOI":"10.1016\/j.hlc.2021.07.006","article-title":"Sex and Gender Aspects in Vascular Ageing \u2013 Focus on Epidemiology, Pathophysiology, and Outcomes.","volume":"30","author":"U Seeland","year":"2021","journal-title":"Heart Lung Circ."},{"key":"ref19","doi-asserted-by":"publisher","first-page":"7934-7945","DOI":"10.1002\/mp.16549","article-title":"Estimating the differences between inter-operator contrast enhancement in cerebral CT angiography.","volume":"50","author":"K Sugimoto","year":"2023","journal-title":"Med. Phys."},{"key":"ref20","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1186\/s12880-024-01373-7","article-title":"Contrast enhancement boost improves the image quality of CT angiography derived from 80-kVp cerebral CT perfusion data.","volume":"24","author":"L Yang","year":"2024","journal-title":"BMC Med. Imaging."},{"key":"ref21","doi-asserted-by":"publisher","first-page":"1198-1208","DOI":"10.1097\/ALN.0000000000000872","article-title":"Cardiac Output and Cerebral Blood Flow.","volume":"123","author":"L Meng","year":"2015","journal-title":"Anesthesiology."},{"key":"ref22","doi-asserted-by":"publisher","first-page":"e0191347","DOI":"10.1371\/journal.pone.0191347","article-title":"Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: Analysis using computer simulation.","volume":"13","author":"T Higaki","year":"2018","journal-title":"PLoS One."},{"key":"ref23","doi-asserted-by":"publisher","first-page":"839-845","DOI":"10.3174\/ajnr. A2388","article-title":"Frequency of adequate contrast opacification of the major intracranial venous structures with CT angiography in the setting of intracerebral hemorrhage: Comparison of 16- and 64-section CT angiography techniques.","volume":"32","author":"J Delgado Almandoz","year":"2011","journal-title":"Am. J. Neuroradiol."},{"key":"ref24","doi-asserted-by":"publisher","first-page":"515-523","DOI":"10.21037\/qims-24-834","article-title":"Effect of different scanning threshold triggers on the image quality of brain computed tomography angiography: a randomized controlled trial.","volume":"15","author":"J Xu","year":"2025","journal-title":"Quant. Imaging Med. Surg."},{"key":"ref25","doi-asserted-by":"publisher","first-page":"35-40","DOI":"10.31983\/jahmt.v5i2.9575","article-title":"Usage of HU Thresholding in Carotid-Cerebral CT Angiography: A Qualitative Study.","volume":"5","author":"I Putu","year":"2023","journal-title":"Journal of Applied Health Management and Technology."},{"key":"ref26","doi-asserted-by":"publisher","first-page":"e29260","DOI":"10.1016\/j.heliyon.2024.e29260","article-title":"Application of bolus tracking: The effect of ROI positions on the images quality of cervicocerebral CT angiography.","volume":"10","author":"H Wu","year":"2024","journal-title":"Heliyon."},{"key":"ref27","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1186\/s12880-025-01613-4","article-title":"Optimization of head and neck vascular CT angiography using variable rate bolus tracking technique and third-generation dual-source CT dual-energy scanning.","volume":"25","author":"W Lin","year":"2025","journal-title":"BMC Med. Imaging."},{"key":"ref28","doi-asserted-by":"publisher","first-page":"26-51","DOI":"10.53730\/ijhs.v9n1.15375","article-title":"Factor analysis of research culture: A comparative study of 3-point and 5-point Likert Scales.","volume":"9","author":"A Obon","year":"2025","journal-title":"Int J. Health Sci. (Qassim)."},{"key":"ref29","doi-asserted-by":"publisher","first-page":"2277-2284","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography--an increasing source of radiation exposure.","volume":"357","author":"D Brenner","year":"2007","journal-title":"N. Engl. J. Med."},{"key":"ref30","article-title":"Size-Specific Dose Estimate (SSDE) for Head CT The Report of AAPM Task Group 293.","year":"2019"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"58-63","DOI":"10.22038\/aojnmb.2019.40863.1276","article-title":"Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT\/CT. Asia Ocean.","volume":"8","author":"V Rajaraman","year":"2020","journal-title":"J. Nucl. Med. Biol."},{"key":"ref32","article-title":"Raw dataset for Optimization of Bolus-Tracking Threshold Levels in Cerebral CT Angiography: Influence of Patient Characteristics on Contrast Enhancement Dynamics and Radiation Dose Metrics.","author":"A Prabhu","year":"2025","journal-title":"Figshare."}],"container-title":["F1000Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/f1000research.com\/articles\/14-1219\/v2\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/f1000research.com\/articles\/14-1219\/v2\/pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/f1000research.com\/articles\/14-1219\/v2\/iparadigms","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T10:29:08Z","timestamp":1770719348000},"score":1,"resource":{"primary":{"URL":"https:\/\/f1000research.com\/articles\/14-1219\/v2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,29]]},"references-count":32,"URL":"https:\/\/doi.org\/10.12688\/f1000research.171062.2","relation":{"has-version":[{"id-type":"doi","id":"10.12688\/f1000research.171062.1","asserted-by":"subject"}],"has-review":[{"id-type":"doi","id":"10.5256\/f1000research.192337.r447835","asserted-by":"subject"},{"id-type":"doi","id":"10.5256\/f1000research.192337.r447835","asserted-by":"object"}]},"ISSN":["2046-1402"],"issn-type":[{"value":"2046-1402","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,29]]},"assertion":[{"value":"Indexed","URL":"https:\/\/f1000research.com\/articles\/14-1219\/v2#article-reports","order":0,"name":"referee-status","label":"Referee status","group":{"name":"current-referee-status","label":"Current Referee Status"}},{"value":"10.5256\/f1000research.188606.r431358, Manna Debnath, Pramukhswami Medical College and Shree Krishna Hospital, Bhaikaka University, Anand, Gujarat, 25 Nov 2025, version 1, 1 approved","URL":"https:\/\/f1000research.com\/articles\/14-1219\/v1#referee-response-431358","order":0,"name":"referee-response-431358","label":"Referee Report","group":{"name":"article-reports","label":"Article Reports"}},{"value":"<b>Abhimanyu Pradhan<\/b>; \n<i>Posted: 26 Nov 2025<\/i>; The current version of this article incorporates several revisions made in response to reviewer feedback and internal review.  First, the scan protocol section has been updated to include the mAs parameter, providing a more detailed and transparent outline of the imaging methodology.  Second, minor inconsistencies in the reporting of participant characteristics have been corrected; specifically, the height value has been standardized to 164 &plusmn; 9.75 across both the text and Table 2 to ensure accuracy and uniformity.  In addition, we clarified the statistical reporting in the Results section by explicitly stating that non-normally distributed variables are presented as median (IQR), thereby aligning the text with the appropriate statistical conventions.","URL":"https:\/\/f1000research.com\/articles\/14-1219\/v2#referee-comment-14998","order":1,"name":"referee-comment-14998","label":"Referee Comment","group":{"name":"article-reports","label":"Article Reports"}},{"value":"10.5256\/f1000research.192337.r447835, Dolly Sharma, Charotar University of Science and Technology, Gujarat, 10 Feb 2026, version 2, indexed","URL":"https:\/\/f1000research.com\/articles\/14-1219\/v2#referee-response-447835","order":2,"name":"referee-response-447835","label":"Referee Report","group":{"name":"article-reports","label":"Article Reports"}},{"value":"The author(s) declared that no grants were involved in supporting this work","order":3,"name":"grant-information","label":"Grant Information"},{"value":"This is an open access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.","order":0,"name":"copyright-info","label":"Copyright"}]}}