{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T22:13:37Z","timestamp":1772662417745,"version":"3.50.1"},"reference-count":14,"publisher":"Medical Association of Nippon Medical School","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Nippon Med Sch"],"published-print":{"date-parts":[[2015]]},"DOI":"10.1272\/jnms.82.220","type":"journal-article","created":{"date-parts":[[2015,11,15]],"date-time":"2015-11-15T22:03:01Z","timestamp":1447624981000},"page":"220-228","source":"Crossref","is-referenced-by-count":10,"title":["Ultrasound Evaluation of the Transverse Movement of the Flexor Pollicis Longus Tendon on the Distal Radius during Wrist and Finger Motion in Healthy Volunteers"],"prefix":"10.1272","volume":"82","author":[{"given":"Mitsuhiko","family":"Nanno","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Nippon Medical School, Musashi Kosugi Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuya","family":"Sawaizumi","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Norie","family":"Kodera","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuji","family":"Tomori","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinro","family":"Takai","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Nippon Medical School"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"21","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Limthongthang R, Bachoura A, Jacoby SM, Osterman AL: Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus. J Hand Surg 2014; 39A: 852-860.","DOI":"10.1016\/j.jhsa.2014.01.038"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Orbay JL, Touhami A: Current concepts in volar fixed angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 2006; 445: 58-67.","DOI":"10.1097\/01.blo.0000205891.96575.0f"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Soong M, Earp BE, Bishop G, Leung A, Blazar P: Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg 2011; 93A: 328-335.","DOI":"10.2106\/JBJS.J.00193"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Tanaka Y, Aoki M, Izumi T, Fujimiya M, Yamashita T, Imai T: Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. J Hand Surg 2011; 36A: 1790-1797.","DOI":"10.1016\/j.jhsa.2011.08.027"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Tarallo L, Mugnai R, Zambianchi F, Adani R, Catani F: Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events. J Orthop Trauma 2013; 27: 740-745.","DOI":"10.1097\/BOT.0b013e3182913fc5"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M: Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007; 21: 316-322.","DOI":"10.1097\/BOT.0b013e318059b993"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Bell JS, Wollstein R, Citron ND: Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius. J Bone Joint Surg 1998; 80B: 225-226.","DOI":"10.1302\/0301-620X.80B2.8351"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Berglund LM, Messer TM: Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg 2009; 17: 369-377.","DOI":"10.5435\/00124635-200906000-00005"},{"key":"9","unstructured":"9. Duncan SF, Weiland AJ: Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius. Am J Orthop (Belle Mead NJ) 2007; 36: 669-670."},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Drobetz H, Kutscha-Lissberg E: Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003; 27: 1-6.","DOI":"10.1007\/s00264-002-0393-x"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland AJ, Daluiski A: Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg 2013; 38A: 1091-1096.","DOI":"10.1016\/j.jhsa.2013.03.011"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Casaletto JA, Machin D, Leung R, Brown DJ: Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg 2009; 34E: 471-474.","DOI":"10.1177\/1753193408100964"},{"key":"13","unstructured":"13. Kameyama M, Takeda K, Komiyama T, Tezuka M, Yanagimoto S: Ultrasonographic study of flexor pollicis longus tendon after volar locking plate fixation in the treatment of fractures of the distal radius (in Japanese). Kossetsu 2012; 34: 25-28."},{"key":"14","unstructured":"14. Doi D: Ultrasonographic evaluation on flexor pollicis tendon injury after distal radius fracture using volar locking plate (in Japanese). J Jpn Soc Surg Hand 2010; 27: 70-73."}],"container-title":["Journal of Nippon Medical School"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jnms\/82\/5\/82_220\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,11]],"date-time":"2020-09-11T11:30:55Z","timestamp":1599823855000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jnms\/82\/5\/82_220\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015]]},"references-count":14,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2015]]}},"URL":"https:\/\/doi.org\/10.1272\/jnms.82.220","relation":{},"ISSN":["1345-4676","1347-3409"],"issn-type":[{"value":"1345-4676","type":"print"},{"value":"1347-3409","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015]]}}}