{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,7]],"date-time":"2025-06-07T05:10:01Z","timestamp":1749273001554,"version":"3.41.0"},"reference-count":28,"publisher":"Japanese Society of Veterinary Science","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Vet. Med. Sci.","The Journal of Veterinary Medical Science"],"published-print":{"date-parts":[[2025]]},"DOI":"10.1292\/jvms.25-0028","type":"journal-article","created":{"date-parts":[[2025,4,20]],"date-time":"2025-04-20T22:06:36Z","timestamp":1745186796000},"page":"667-674","source":"Crossref","is-referenced-by-count":0,"title":["A basic study on the mechanical properties of synthetic absorbable sutures          under various pH conditions &lt;i&gt;in vitro&lt;\/i&gt;"],"prefix":"10.1292","volume":"87","author":[{"given":"Mizuki","family":"TOMIHARI","sequence":"first","affiliation":[{"name":"School of Veterinary Science, Osaka Metropolitan University, Osaka,              Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kei","family":"YAMANOKUCHI","sequence":"additional","affiliation":[{"name":"Kamishihoro Veterinary Clinic, Hokkaido NOSAI, Hokkaido,              Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masashi","family":"YANAGAWA","sequence":"additional","affiliation":[{"name":"Veterinary Teaching Hospital, Joint Graduate School of Veterinary Medicine,              Kagoshima University, Kagoshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michihito","family":"TAGAWA","sequence":"additional","affiliation":[{"name":"Faculty of Veterinary Medicine, Okayama University of Science, Ehime,              Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiyuki","family":"TANAKA","sequence":"additional","affiliation":[{"name":"School of Veterinary Science, Osaka Metropolitan University, Osaka,              Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"HASEGAWA","sequence":"additional","affiliation":[{"name":"School of Veterinary Science, Osaka Metropolitan University, Osaka,              Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"122","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Akt\u0131              A, Kaya              DI. 2024.            Evaluation of tensile strength of surgically absorbable suture materials            used in oral surgery after immersion in different beverages: An <i>in              vitro<\/i> study. <i>Materials            (Basel)<\/i>          17: 3586.","DOI":"10.3390\/ma17143586"},{"key":"2","unstructured":"2. Biosyn. https:\/\/www.medtronic.com\/en-us\/healthcare-professionals\/products\/wound-closure\/sutures\/absorbable-sutures\/biosyn-monofilament-absorbable-suture.html          [accessed on January 14, 2025]."},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Chu              CC, Moncrief              G. 1983.            An <i>in vitro<\/i> evaluation of the stability of mechanical            properties of surgical suture materials in various pH conditions.              <i>Ann Surg<\/i>          198: 223\u2013228.","DOI":"10.1097\/00000658-198308000-00019"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Chung              E, McPherson              N, Grant              A. 2009.            Tensile strength of absorbable suture materials: <i>in              vitro<\/i> analysis of the effects of pH and bacteria.              <i>J Surg Educ<\/i>          66: 208\u2013211.","DOI":"10.1016\/j.jsurg.2009.06.007"},{"key":"5","unstructured":"5. Ethicon. Wound closure manual. https:\/\/anwresidency.com\/simulation\/guide\/resources\/Ethicon_Wound_Closure_manual.pdf [accessed on January 14,          2025]."},{"key":"6","unstructured":"6. Fossum              TW. 2019.          Biomaterials, suturing, and haemostasis. pp. 60\u201364. In: Small Animal Surgery, 5th ed.          (Fossum TW, Welch T eds.), Elsevier, St. Louis."},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Freudenberg              S, Rewerk              S, Kaess              M, Weiss              C,                Dorn-Beinecke              A, Post              S. 2004.            Biodegradation of absorbable sutures in body fluids and pH            buffers. <i>Eur Surg Res<\/i>          36: 376\u2013385.","DOI":"10.1159\/000081648"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Greenberg              CB, Davidson              EB, Bellmer              DD, Morton              RJ, Payton              ME. 2004.            Evaluation of the tensile strengths of four monofilament absorbable            suture materials after immersion in canine urine with or without            bacteria. <i>Am J Vet Res<\/i>          65: 847\u2013853.","DOI":"10.2460\/ajvr.2004.65.847"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Greenwald              D, Shumway              S, Albear              P, Gottlieb              L. 1994.            Mechanical comparison of 10 suture materials before and after in vivo            incubation. <i>J Surg Res<\/i>          56: 372\u2013377.","DOI":"10.1006\/jsre.1994.1058"},{"key":"10","unstructured":"10. Justan              I. 2010.            Evaluation of suture material characteristics in an <i>in              vitro<\/i> experimental model. <i>Acta Chir              Plast<\/i>          52: 45\u201348."},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Karabulut              R, Sonmez              K, Turkyilmaz              Z, Bagbanci              B, Basaklar              AC, Kale              N. 2010.            An <i>in vitro<\/i> and in vivo evaluation of tensile strength            and durability of seven suture materials in various pH and different conditions: An            experimental study in rats. <i>Indian J            Surg<\/i>          72: 386\u2013390.","DOI":"10.1007\/s12262-010-0158-5"},{"key":"12","unstructured":"12. Kawasaki Seibutsu Co.,            Ltd. Suture. http:\/\/kawasaki-seibutsu.com\/products\/vomel\/ [accessed on January 14,          2025]."},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Kearney              CM, Buckley              CT, Jenner              F,                Moissonnier              P, Brama              PAJ. 2014.            Elasticity and breaking strength of synthetic suture materials incubated            in various equine physiological and pathological solutions.              <i>Equine Vet J<\/i>          46: 494\u2013498.","DOI":"10.1111\/evj.12181"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Khiste              SV, Ranganath              V, Nichani              AS. 2013.            Evaluation of tensile strength of surgical synthetic absorbable suture            materials: an <i>in vitro<\/i> study. <i>J              Periodontal Implant Sci<\/i>          43: 130\u2013135.","DOI":"10.5051\/jpis.2013.43.3.130"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Kim              JC, Lee              YK, Lim              BS, Rhee              SH, Yang              HC. 2007.            Comparison of tensile and knot security properties of surgical            sutures. <i>J Mater Sci Mater Med<\/i>          18: 2363\u20132369.","DOI":"10.1007\/s10856-007-3114-6"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Kreszinger              M, Toholj              B, A\u010danski              A, Balo\u0161              S, Cincovi\u0107              M, Pe\u0107in              M, Lipar              M, Smolec              O. 2018.            Tensile strength retention of resorptive suture materials applied in the            stomach wall \u2212An <i>in vitro<\/i> study. <i>Vet              Arh<\/i>          88: 235\u2013243.","DOI":"10.24099\/vet.arhiv.170130"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. la                Puerta              B, Parsons              KJ, Draper              ERC, Moores              AL, Moores              AP. 2011.              <i>In vitro<\/i> comparison of mechanical and degradation            properties of equivalent absorbable suture materials from two different            manufacturers. <i>Vet Surg<\/i>          40: 223\u2013227.","DOI":"10.1111\/j.1532-950X.2010.00768.x"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Lapointe              S, Zhim              F, Sid\u00e9ris              L, Drolet              P,                C\u00e9lestin-No\u00ebl              S, Dub\u00e9              P. 2016.            Effect of chemotherapy and heat on biomechanical properties of absorbable            sutures. <i>J Surg Res<\/i>          200: 59\u201365.","DOI":"10.1016\/j.jss.2015.06.028"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19. Liber-Kne\u0107              A, \u0141agan              S. 2016.            The stress relaxation process in sutures tied with a surgeon\u2019s knot in a            simulated biological environment. <i>Polim            Med<\/i>          46: 111\u2013116.","DOI":"10.17219\/pim\/68735"},{"key":"20","unstructured":"20. Maxon. https:\/\/www.medtronic.com\/en-us\/healthcare-professionals\/products\/wound-closure\/sutures\/absorbable-sutures\/maxon-monofilament-absorbable-suture.html [accessed on January 14,          2025]."},{"key":"21","doi-asserted-by":"crossref","unstructured":"21. M\u00fcller              DA, Snedeker              JG, Meyer              DC. 2016.            Two-month longitudinal study of mechanical properties of absorbable            sutures used in orthopedic surgery. <i>J Orthop Surg              Res<\/i>          11: 111.","DOI":"10.1186\/s13018-016-0451-5"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22. Naleway              SE, Lear              W, Kruzic              JJ, Maughan              CB. 2015.            Mechanical properties of suture materials in general and cutaneous            surgery. <i>J Biomed Mater Res B Appl            Biomater<\/i>          103: 735\u2013742.","DOI":"10.1002\/jbm.b.33171"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Nobile              L, Checchi              L, Monaco              G. 1997.            Experimental analysis of tensile properties of some suturing            materials. <i>J Mater Sci Mater Med<\/i>          8: 53\u201356.","DOI":"10.1023\/A:1018594330075"},{"key":"24","unstructured":"24. Outlaw              KK, Vela              AR, O\u2019Leary              JP. 1998.            Breaking strength and diameter of absorbable sutures after in vivo            exposure in the rat. <i>Am Surg<\/i>          64: 348\u2013354."},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Pillai              CKS, Sharma              CP. 2010.            Review paper: absorbable polymeric surgical sutures: chemistry,            production, properties, biodegradability, and performance.              <i>J Biomater Appl<\/i>          25: 291\u2013366.","DOI":"10.1177\/0885328210384890"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Taysi              AE, Ercal              P, Sismanoglu              S. 2021.            Comparison between tensile characteristics of various suture materials            with two suture techniques: an <i>in vitro<\/i> study.              <i>Clin Oral Investig<\/i>          25: 6393\u20136401.","DOI":"10.1007\/s00784-021-03943-3"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Tobias              KM, Kidd              CE, Mulon              PY, Zhu              X. 2020.            Tensile properties of synthetic, absorbable monofilament suture materials            before and after incubation in phosphate-buffered saline.              <i>Vet Surg<\/i>          49: 550\u2013560.","DOI":"10.1111\/vsu.13326"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Vasanthan              A, Satheesh              K, Hoopes              W, Lucaci              P, Williams              K, Rapley              J. 2009.            Comparing suture strengths for clinical applications: a novel <i>in              vitro<\/i> study. <i>J Periodontol<\/i>          80: 618\u2013624.","DOI":"10.1902\/jop.2009.080490"}],"container-title":["Journal of Veterinary Medical Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jvms\/87\/6\/87_25-0028\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,7]],"date-time":"2025-06-07T04:39:56Z","timestamp":1749271196000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jvms\/87\/6\/87_25-0028\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1292\/jvms.25-0028","relation":{},"ISSN":["0916-7250","1347-7439"],"issn-type":[{"type":"print","value":"0916-7250"},{"type":"electronic","value":"1347-7439"}],"subject":[],"published":{"date-parts":[[2025]]},"article-number":"25-0028"}}