{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T13:16:45Z","timestamp":1775827005986,"version":"3.50.1"},"reference-count":29,"publisher":"Mark Allen Group","issue":"Sup7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Br J Nurs"],"published-print":{"date-parts":[[2026,4,1]]},"abstract":"<jats:p>Peristomal skin complications are common in patients following a laryngectomy because of the repeated use of devices requiring medical adhesive. Medical adhesive-related skin injury (MARSI) is increasingly recognised as a preventable source of pain, infection risk and reduced quality of life. Laryngectomy patients are particularly vulnerable owing to age-related skin changes, radiotherapy, malnutrition and prolonged moisture exposure. Historically, MARSI has been accepted as an unwelcome side effect of care in this patient group. This article explores the pathophysiology of MARSI, risk factors specific to the laryngectomy population and the importance of preserving the skin's acid mantle. Best practice in prevention and management includes optimal adhesive removal techniques, and selecting an appropriate adhesive and barrier products. Integrating a structured peristomal skin assessment tool into clinical practice would support speech and language therapists and clinical nurse specialists in the early identification of skin problems, prompt adapted care and facilitate patient education. A proactive approach is essential to minimise skin injury and improve overall patient outcomes.<\/jats:p>","DOI":"10.12968\/bjon.2026.0062","type":"journal-article","created":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T12:05:29Z","timestamp":1775822729000},"page":"2-7","source":"Crossref","is-referenced-by-count":0,"title":["Silicone adhesives and skin health in laryngectomy care"],"prefix":"10.12968","volume":"35","author":[{"given":"Alexandra J","family":"Bishop","sequence":"first","affiliation":[{"name":"Nurse Consultant in Tissue Viability, University Hospitals Plymouth"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5130","reference":[{"key":"e_1_3_2_1_1","unstructured":"Atos Medical. Healthy peristomal skin: a foundation for successful voice and pulmonary rehabilitation. White paper. Atos Medical; 2023. https:\/\/www.atosmedical.com\/healthcare-professionals\/laryngectomy\/skin-health (accessed 2 March 2026)"},{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/WON.0000000000001116"},{"key":"e_1_3_2_3_1","unstructured":"BDK. Benefits of different adhesive technologies in woundcare. 24 April 2023. https:\/\/www.bdk.uk.com\/2023\/04\/benefits-of-different-adhesive-technologies-in-woundcare\/ (accessed 25 February 2026)"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1089\/wound.2022.0021"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.2147\/JMDH.S118419"},{"key":"e_1_3_2_6_1","unstructured":"Brierley AJ. The design & verication of an automatic occlusion speech valve for voice rehabilitation. MSc thesis submitted to Durham University 2022. https:\/\/etheses.dur.ac.uk\/14449\/1\/Brierley000794728.pdf (accessed 25 February 2026]"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jid.2024.07.009"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-023-08139-x"},{"key":"e_1_3_2_9_1","first-page":"3","article-title":"Evidence review: the clinical benefits of Safetac technology in wound care","author":"Davies P","year":"2008","unstructured":"Davies P, Rippon M. Evidence review: the clinical benefits of Safetac technology in wound care. J Wound Care. 2008;suppl:3\u201331","journal-title":"J Wound Care"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.12968\/jowc.2024.0308"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/ASW.0000000000000235"},{"issue":"9","key":"e_1_3_2_12_1","first-page":"412","article-title":"Comparison of adhesive technologies and skin effects","volume":"20","author":"Dykes PJ","year":"2011","unstructured":"Dykes PJ, Heggie R, O'Neill S. Comparison of adhesive technologies and skin effects. J Wound Care. 2011;20(9):412\u2013422","journal-title":"J Wound Care"},{"issue":"1","key":"e_1_3_2_13_1","first-page":"1","article-title":"Preventing medical adhesive-related skin injury (MARSI): best practice and the role of sterile medical adhesive removers","volume":"22","author":"Holloway S","year":"2026","unstructured":"Holloway S, Downie F. Preventing medical adhesive-related skin injury (MARSI): best practice and the role of sterile medical adhesive removers. Wounds UK. 2026;22(1):1\u20136","journal-title":"Wounds UK"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-58423-x"},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/iwj.13028"},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.30636"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/WON.0000000000000162"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/MOO.0000000000000046"},{"issue":"4","key":"e_1_3_2_19_1","first-page":"1","article-title":"Medical adhesive-related skin injuries (MARSI) made easy","volume":"12","author":"McNichol L","year":"2016","unstructured":"McNichol L, Bianchi J. Medical adhesive-related skin injuries (MARSI) made easy. Wounds UK. 2016;12(4):1\u20134","journal-title":"Wounds UK"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/JDN.0000000000000009"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.7748\/paed2009.04.21.3.38.c7037"},{"key":"e_1_3_2_22_1","unstructured":"NHS Business Services Authority. Clinical review: skin barrier film. (V1.2) 11.2017. 2017. https:\/\/www.nhsbsa.nhs.uk\/sites\/default\/files\/2017-11\/Skin%20Barrier%20Films%20-%20Final%20%20Report%20%28V1.2%29%2011.2017.pdf (accessed 25 February 2026)"},{"issue":"7","key":"e_1_3_2_23_1","first-page":"33","article-title":"Skin surface pH in acne vulgaris: insights from an observational study and review of the literature","volume":"10","author":"Prakash C","year":"2017","unstructured":"Prakash C, Bhargava P, Tiwari S, Majumdar B, Bhargava RK. Skin surface pH in acne vulgaris: insights from an observational study and review of the literature. J Clin Aesthet Dermatol. 2017;10(7):33\u201339","journal-title":"J Clin Aesthet Dermatol"},{"issue":"3","key":"e_1_3_2_24_1","first-page":"28","article-title":"Medical adhesive-related skin injury (MARSI): preventing patient harm","volume":"15","author":"Savine L","year":"2024","unstructured":"Savine L, Snelson K. Medical adhesive-related skin injury (MARSI): preventing patient harm. Wounds International. 2024;15(3):28\u201336","journal-title":"Wounds International"},{"key":"e_1_3_2_25_1","doi-asserted-by":"publisher","DOI":"10.1080\/00016480510031506"},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtv.2024.10.007"},{"key":"e_1_3_2_27_1","unstructured":"Williams A Cowdell F G Moncrieff et al; Wounds UK. Best practice statement: maintaining skin integrity. Wounds UK. 2018. https:\/\/wounds-uk.com\/best-practice-statements\/maintaining-skin-integrity\/ (accessed 25 February 2026)"},{"key":"e_1_3_2_28_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.133.6.526"},{"key":"e_1_3_2_29_1","unstructured":"Yun JSW Nixon R. Skin barrier function. DermNet; March 2021. https:\/\/dermnetnz.org\/topics\/skin-barrier-function (accessed 25 February 2026)"}],"container-title":["British Journal of Nursing"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.magonlinelibrary.com\/doi\/pdf\/10.12968\/bjon.2026.0062","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T12:05:37Z","timestamp":1775822737000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.magonlinelibrary.com\/doi\/10.12968\/bjon.2026.0062"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,1]]},"references-count":29,"journal-issue":{"issue":"Sup7","published-print":{"date-parts":[[2026,4,1]]}},"alternative-id":["10.12968\/bjon.2026.0062"],"URL":"https:\/\/doi.org\/10.12968\/bjon.2026.0062","relation":{},"ISSN":["0966-0461","2052-2819"],"issn-type":[{"value":"0966-0461","type":"print"},{"value":"2052-2819","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,1]]}}}