{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T03:18:24Z","timestamp":1768447104466,"version":"3.49.0"},"reference-count":37,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"11","license":[{"start":{"date-parts":[[2005,11,1]],"date-time":"2005-11-01T00:00:00Z","timestamp":1130803200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2005,11]]},"abstract":"<jats:p> We investigated the rate of polyethylene wear of a cementless acetabular component at different periods of follow-up in order to test the hypothesis than an irrecoverable deformation process (creep) was followed by an initially low, but gradually increasing wear rate. We studied prospectively 93 uncemented total hip arthroplasties in 83 patients (mean age 50 years (22 to 63)) with a mean follow-up of 8.2 years (3 to 12). We measured the penetration of the femoral head from radiographs taken immediately after surgery at three, six and nine years, or at the latest follow-up. <\/jats:p><jats:p> The median wear rate was 0.17 mm per year in the first three years, a finding which we considered to be caused by creep. Thereafter, the rate of wear declined to 0.07 mm per year (four- to six-year period) and then increased to 0.17 mm per year (seven to nine years) and 0.27 mm per year (more than nine years), which we considered to be a reflection of genuine polyethylene wear. After the nine-year follow-up the wear rates were higher in patients with marked osteolysis. We found no relationship between the inclination angle of the acetabular component or femoral head orientation and the rate of wear. No acetabular component required revision. <\/jats:p>","DOI":"10.1302\/0301-620x.87b11.16101","type":"journal-article","created":{"date-parts":[[2005,10,31]],"date-time":"2005-10-31T21:18:43Z","timestamp":1130793523000},"page":"1475-1479","source":"Crossref","is-referenced-by-count":14,"title":["Mid-term wear characteristics of an uncemented acetabular component"],"prefix":"10.1302","volume":"87-B","author":[{"given":"J. H. M.","family":"Goosen","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Isala Clinics, Weezenlanden Hospital, 8011 JW Zwolle, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. C. P. M.","family":"Verheyen","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Isala Clinics, Weezenlanden Hospital, 8011 JW Zwolle, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N. J. A.","family":"Tulp","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Isala Clinics, Weezenlanden Hospital, 8011 JW Zwolle, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.3109\/17453679308993679"},{"key":"R2","unstructured":"Harris WH. The problem is osteolysis. Clin Orthop 1995;311:46\u201353."},{"key":"R3","unstructured":"Willert HG, Buchhorn GH, Hess T. The significance of wear and material fatigue in loosening of hip prostheses. Orthopade 1989;18:350\u201369 (in German)."},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Charnley J, Cupec Z. The nine and ten year results of the low-friction arthroplasty of the hip. Clin Orthop 1973;95:9\u201325.","DOI":"10.1097\/00003086-197309000-00003"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Charnley J, Halley DK. Rate of wear in total hip replacement. Clin Orthop 1975;112: 170\u20139.","DOI":"10.1097\/00003086-197510000-00021"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Isaac GH, Dowson D, Wroblewski BM. An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups: wear, creep or degradation? Proc Inst Mech Eng (H) 1996;210:209\u201316.","DOI":"10.1243\/PIME_PROC_1996_210_414_02"},{"key":"R7","doi-asserted-by":"crossref","unstructured":"Gomez-Barrena E, Li S, Furman BS, et al. Role of polyethylene oxidation and consolidation defects in cup performance. Clin Orthop 1988;352:105\u201317.","DOI":"10.1097\/00003086-199807000-00013"},{"key":"R8","doi-asserted-by":"crossref","unstructured":"Kurtz SM, Hozack W, Marcolongo M, et al. Degradation of mechanical properties of UHMWPE acetabular liners following long-term implantation. J Arthroplasty 2003; 18:68\u201378.","DOI":"10.1016\/S0883-5403(03)00292-4"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-196951040-00012"},{"key":"R10","unstructured":"Sellers RG, Lyles D, Dorr LD. The effect of pelvic rotation on alpha and theta angles in total hip arthroplasty. Cont Orth 1988;17:67\u201370."},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200107000-00020"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199072040-00008"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1080\/000164701753759555"},{"key":"R14","doi-asserted-by":"crossref","unstructured":"DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976;121:20\u201332.","DOI":"10.1097\/00003086-197611000-00003"},{"key":"R15","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNiece GM, Amstutz HC. \u201cModes of failure\u201d of cemented stem type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141: 17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"R16","doi-asserted-by":"crossref","unstructured":"Sarmiento A, Ebramzadeh E, Gogan WJ, McKellop HA. Cup containment and orientation in cemented total hip arthroplasties. J Bone Joint Surg [Am] 1990;72-A: 996\u20131002.","DOI":"10.1302\/0301-620X.72B6.2246305"},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)80003-X"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200012000-00005"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1016\/0883-5403(94)90059-0"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Maloney WJ, Peters P, Engh CA, Chandler H. Severe osteolysis of the pelvic in association with acetabular replacement without cement. J Bone Joint Surg [Am] 1993;75-A:1627\u201335.","DOI":"10.2106\/00004623-199311000-00007"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1243\/0954411991534861"},{"key":"R22","unstructured":"Postak PD, Tradonsky S, Froimson AI, Greenwald AS. Performance characteristics of two piece acetabular cups: series II [abstract]. Orthop Trans 1996;20:182\u20133."},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(82)90248-2"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.75B2.8444945"},{"key":"R25","doi-asserted-by":"crossref","unstructured":"Devane PA, Bourne RB, Rorabeck CH, MacDonald S, Robinson EJ. Measurement of polyethylene wear in metal-backed acetabular cups. Clin Orthop 1995;319: 317\u201326.","DOI":"10.1097\/00003086-199510000-00034"},{"key":"R26","doi-asserted-by":"crossref","unstructured":"Hozack WJ, Rothman RH, Eng K, Mesa J. Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop 1996;333:217\u201325.","DOI":"10.1097\/00003086-199612000-00023"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(99)90074-8"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Thanner J. The acetabular component in total hip arthroplasty: evaluation of different fixation principles. Acta Orthop Scand Suppl 1999;286:1\u201341.","DOI":"10.1080\/17453674.1999.11744830"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1007\/s00776-003-0689-8"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100150109"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(03)00146-3"},{"key":"R32","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000150314.70919.e3"},{"key":"R33","unstructured":"Doorn PF. Wear and biological aspects of metal on metal total hip replacements. Thesis. Nijmegen, The Netherlands: University Medical Center, Nijmegen, 2000:13."},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199608000-00009"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199608001-00005"},{"key":"R36","doi-asserted-by":"publisher","DOI":"10.1177\/112070000001000402"},{"key":"R37","doi-asserted-by":"crossref","unstructured":"Konttinen YT, Zhao D, Beklen A, et al. The microenvironment around total hip replacement prostheses. Clin Orthop 2005;430:28\u201338.","DOI":"10.1097\/01.blo.0000150451.50452.da"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B11.16101","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.87B11.16101","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B11.16101","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:09:37Z","timestamp":1629144577000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.87B11.16101"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,11]]},"references-count":37,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2005,11]]}},"alternative-id":["10.1302\/0301-620X.87B11.16101"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.87b11.16101","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,11]]}}}