{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T19:47:38Z","timestamp":1762458458943},"reference-count":17,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"11","license":[{"start":{"date-parts":[[2005,11,1]],"date-time":"2005-11-01T00:00:00Z","timestamp":1130803200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2005,11]]},"abstract":"<jats:p> We analysed at a mean follow-up of 7.25 years the clinical and radiological outcome of 117 patients (125 knees) who had undergone a primary, cemented, modular Freeman-Samuelson total knee replacement. While the tibial and femoral components were cemented, the patellar component was uncemented. A surface-cementing technique was used to secure the tibial components. A total of 82 knees was available for radiological assessment. Radiolucent lines were seen in 41 knees (50%) and osteolytic lesions were seen in 13 knees (16%). Asymptomatic, rotational loosening of the patellar implant was seen in four patients and osteolysis was more common in patients with a patellar resurfacing. Functional outcome scores were available for 41 patients (41 knees, 35%) and the mean Western Ontario McMasters Universities score was 77.5 (sd 19.5) and the cumulative survival was 93.4% at ten years with revision for aseptic loosening as an endpoint. Increased polyethylene wear from modular components, a rotationally-loose patella, and the surface-cementing technique may have contributed to the high rate of osteolysis seen in our study. <\/jats:p>","DOI":"10.1302\/0301-620x.87b11.16586","type":"journal-article","created":{"date-parts":[[2005,10,31]],"date-time":"2005-10-31T21:18:43Z","timestamp":1130793523000},"page":"1502-1506","source":"Crossref","is-referenced-by-count":8,"title":["Osteolysis in a surface-cemented, primary, modular Freeman-Samuelson total knee replacement"],"prefix":"10.1302","volume":"87-B","author":[{"given":"J.","family":"Arora","sequence":"first","affiliation":[{"name":"Department of Trauma and Orthopaedics, North Tyneside General Hospital, Rake Lane, North Shields, Northumbria NE29 8NH, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. C.","family":"Ogden","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedics, Dumfries and Galloway Royal Infirmary, Bankend, Dumfries DG1 4AP, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.82B4.0820506"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000093886.12372.74"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(99)99999-0"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop 1989;248:9\u201312.","DOI":"10.1097\/00003086-198911000-00003"},{"key":"R5","unstructured":"Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 1988;15:1833\u201340."},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200112000-00007"},{"key":"R7","doi-asserted-by":"crossref","unstructured":"Schmalzried TP, Callaghan JJ. Wear in total hip and knee replacements. J Bone Joint Surg [Am] 1999;81-A:115\u201336.","DOI":"10.2106\/00004623-199901000-00016"},{"key":"R8","doi-asserted-by":"crossref","unstructured":"Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg [Am] 1986;68-A:1041\u201351.","DOI":"10.2106\/00004623-198668070-00010"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B1.1732274"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Wasielewski RC, Parks N, Williams I, et al. Tibial insert undersurface as a contributing source of polyethylene wear debris. Clin Orthop 1997;345:53\u20139.","DOI":"10.1097\/00003086-199712000-00009"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Robinson EJ, Mulliken BD, Bourne RB, Rorabeck CH, Alvarez C. Catastrophic osteolysis in total knee replacement: a report of 17 cases. Clin Orthop 1995;321:98\u2013105.","DOI":"10.1097\/00003086-199512000-00015"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.29328"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2000.4342"},{"key":"R14","doi-asserted-by":"crossref","unstructured":"Rand JA, Trousdale RT, Ilstrup DM, Harmsen WS. Factors affecting the durability of primary total knee prosthesis. J Bone Joint Surg [Am] 2003;85-A:259\u201365.","DOI":"10.2106\/00004623-200302000-00012"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000058638.94987.20"},{"key":"R16","unstructured":"Bourgeault ST, Chareancholvanich K, Lew W, et al. Does a central stem effect bone strain and the stability of a cemented tibial tray in primary and revision TKA? Trans Orthop Res Soc 1997;22:635."},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200211000-00003"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B11.16586","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.87B11.16586","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B11.16586","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:10:17Z","timestamp":1629144617000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.87B11.16586"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,11]]},"references-count":17,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2005,11]]}},"alternative-id":["10.1302\/0301-620X.87B11.16586"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.87b11.16586","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,11]]}}}