{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T11:56:14Z","timestamp":1769169374889,"version":"3.49.0"},"reference-count":31,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"11","license":[{"start":{"date-parts":[[2005,11,1]],"date-time":"2005-11-01T00:00:00Z","timestamp":1130803200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2005,11]]},"abstract":"<jats:p> We inserted an electrode up the femoral neck into the femoral head of ten patients undergoing a metal-on-metal hip resurfacing arthroplasty through a posterior surgical approach and measured the oxygen concentration during the operation. In every patient the blood flow was compromised during surgery, but the extent varied. In three patients, the oxygen concentration was zero at the end of the procedure. The surgical approach caused a mean 60% drop (p &lt; 0.005) in oxygen concentration while component insertion led to a further 20% drop (p &lt; 0.04). The oxygen concentration did not improve significantly on wound closure. This study demonstrates that during hip resurfacing arthroplasty, patients experience some compromise to their femoral head blood supply and some have complete disruption. <\/jats:p>","DOI":"10.1302\/0301-620x.87b11.16780","type":"journal-article","created":{"date-parts":[[2005,10,31]],"date-time":"2005-10-31T21:18:43Z","timestamp":1130793523000},"page":"1468-1474","source":"Crossref","is-referenced-by-count":87,"title":["The effect of hip resurfacing on oxygen concentration in the femoral head"],"prefix":"10.1302","volume":"87-B","author":[{"given":"R. T.","family":"Steffen","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. R.","family":"Smith","sequence":"additional","affiliation":[{"name":"Department of Physiology, University of Oxford, Parks Road, Oxford OX1 3PT, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. P. G.","family":"Urban","sequence":"additional","affiliation":[{"name":"Department of Physiology, University of Oxford, Parks Road, Oxford OX1 3PT, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"McLardy-Smith","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. J.","family":"Beard","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H. S.","family":"Gill","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. W.","family":"Murray","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Nuffield Orthopaedic Centre, Windmill Road, Oxford OX3 7LD, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200200002-00002"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.75B4.8331119"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Charnley J. Low friction arthroplasty of the hip: theory and practice. Berlin: Springer-Verlag, 1979.","DOI":"10.1007\/978-3-642-67013-8"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Archibeck MJ, Berger RA, Jacobs JJ, et al. Second-generation cementless total hip arthroplasty: eight to eleven-year results. J Bone Joint Surg [Am] 2001;83-A: 1666\u201373.","DOI":"10.2106\/00004623-200111000-00008"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200112000-00010"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Dorr LD, Wan Z, Longjohn DB, Dubois B, Murken R. Total hip arthroplasty with use of the Metasul metal-on-metal articulation: four to seven-year results. J Bone Joint Surg [Am] 2000;82-A:789\u201398.","DOI":"10.2106\/00004623-200006000-00005"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199608001-00011"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.86B2.14600"},{"key":"R9","doi-asserted-by":"crossref","unstructured":"Capello WN, Ireland PH, Trammell TR, Eicher P. Conservative total hip arthroplasty: a procedure to conserve bone stock. Part I: analysis of sixty-six patients. Part II: analysis of failures. Clin Orthop 1978;134:59\u201374.","DOI":"10.1097\/00003086-197807000-00010"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Freeman MA, Cameron HU, Brown GC. Cemented double cup arthroplasty of the hip: a 5 year experience with the OCLH prosthesis. Clin Orthop 1978;134:45\u201352.","DOI":"10.1097\/00003086-197807000-00008"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Trentani C, Vaccarino F. The Patrinieri-Trentani hip joint resurface arthroplasty. Clin Orthop 1978;134:36\u201340.","DOI":"10.1097\/00003086-197807000-00006"},{"key":"R12","doi-asserted-by":"crossref","unstructured":"Beaule PE, Le Duff M, Campbell P, et al. Metal-on-metal surface arthroplasty with a cemented femoral component: a 7\u201310 year follow-up study. J Arthroplasty 2004; 19(Suppl 3):17\u201322.","DOI":"10.1016\/S0883-5403(04)00489-9"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B1.14702"},{"key":"R14","doi-asserted-by":"crossref","unstructured":"Gerard Y. Hip arthroplasty by matching cups. Clin Orthop 1978;134:25\u201335.","DOI":"10.1097\/00003086-197807000-00005"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B4.15498"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B3.15330"},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B2.15030"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Milgram JW, Rana NA. Pathologic evaluation of the failed cup arthroplasty: a review of 32 cases. Clin Orthop 1981;158:158\u201379.","DOI":"10.1097\/00003086-198107000-00025"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(00)91415-3"},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1978.45.4.637"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1979.tb06306.x"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/52.8.715"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1023\/A:1018653521686"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(98)00052-9"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1016\/S0007-1226(97)90331-3"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199801010-00001"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200210150-00007"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Forrest N, Ashcroft, Murray D. Femoral head viability after Birmingham resurfacing hip arthroplasty: assessment using positron emission tomography [abstract]. Procs 7th EFORT Congress, 2005.","DOI":"10.2106\/00004623-200611001-00013"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.35B3.442"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.82B5.0820679"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B2.0840300"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B11.16780","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.87B11.16780","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B11.16780","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:09:22Z","timestamp":1629144562000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.87B11.16780"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,11]]},"references-count":31,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2005,11]]}},"alternative-id":["10.1302\/0301-620X.87B11.16780"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.87b11.16780","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,11]]}}}