{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T16:05:44Z","timestamp":1764259544132},"reference-count":37,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"5","license":[{"start":{"date-parts":[[2005,5,1]],"date-time":"2005-05-01T00:00:00Z","timestamp":1114905600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2005,5]]},"abstract":"<jats:p> Clinical experience of impaction bone grafting for revision knee arthroplasty is limited, with initial stability of the tibial tray emerging as a major concern. The length of the stem and its diameter have been altered to improve stability. Our aim was to investigate the effect of the type of stem, support of the rim and graft impaction on early stability of the tray. <\/jats:p><jats:p> We developed a system for impaction grafting of trays which we used with morsellised bone in artificial tibiae. Trays with short, long thick or long thin stems were implanted, with or without support of the rim. They were cyclically loaded while measuring relative movement. <\/jats:p><jats:p> Long-stemmed trays migrated 4.5 times less than short-stemmed trays, regardless of diameter. Those with support migrated 2.8 times less than those without. The migration of short-stemmed trays correlated inversely with the density of the impacted groups. That of impaction-grafted tibial trays was in the range reported for uncemented primary trays. Movements of short-stemmed trays without cortical support were largest and sensitive to the degree of compaction of the graft. If support of the rim was sufficient or a long stem was used, impacted morsellised bone graft achieved adequate initial stability. <\/jats:p>","DOI":"10.1302\/0301-620x.87b5.15860","type":"journal-article","created":{"date-parts":[[2005,4,26]],"date-time":"2005-04-26T18:53:15Z","timestamp":1114541595000},"page":"656-663","source":"Crossref","is-referenced-by-count":26,"title":["Mechanical testing of impaction bone grafting in the tibia"],"prefix":"10.1302","volume":"87-B","author":[{"given":"A. D.","family":"Toms","sequence":"first","affiliation":[{"name":"The Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, Shropshire SY10 7AG, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"McClelland","sequence":"additional","affiliation":[{"name":"The Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, Shropshire SY10 7AG, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Chua","sequence":"additional","affiliation":[{"name":"The Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, Shropshire SY10 7AG, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"de Waal Malefijt","sequence":"additional","affiliation":[{"name":"University Medical Centre, Nijmegen, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Verdonschot","sequence":"additional","affiliation":[{"name":"University Medical Centre, Nijmegen, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R. Spencer","family":"Jones","sequence":"additional","affiliation":[{"name":"The Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, Shropshire SY10 7AG, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.-H.","family":"Kuiper","sequence":"additional","affiliation":[{"name":"The Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, Shropshire SY10 7AG, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","unstructured":"Kuiper JH, van Uem B, Nekkers G, et al. Early mechanical stability of impaction grafted prosthese correlates strongly with degree of impaction [abstract]. Trans 8th Conference European Orthopaedic Research Society, 1998."},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.81B6.0811052"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.75B1.8421012"},{"key":"R4","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199603000-00013"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.80B3.0800391"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Capello WN. Impaction grafting plus cement for femoral component fixation in revision hip arthroplasty. Orthopedics 1994;17:878\u20139.","DOI":"10.3928\/0147-7447-19940901-44"},{"key":"R7","doi-asserted-by":"crossref","unstructured":"Nelissen RGHH, Bauer TW, Weidenhielm LRA, Legolvan DP, Mikhail WE. Revision hip arthroplasty with the use of cement and impaction grafting: histological analysis of four cases. J Bone Joint Surg [Am] 1995;77-A:412\u201322.","DOI":"10.2106\/00004623-199503000-00011"},{"key":"R8","doi-asserted-by":"crossref","unstructured":"Elting JJ, Mikhail WEM, Zicat BA, et al. Preliminary report of impaction grafting for exchange femoral arthroplasty. Clin Orthop 1995;319:159\u201367.","DOI":"10.1097\/00003086-199510000-00016"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1080\/000164700317413094"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.29391"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.3109\/17453679608995600"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200002000-00013"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2001.22391"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1080\/00016470052943991"},{"key":"R15","doi-asserted-by":"crossref","unstructured":"Kuiper JH, Richardson JB, Soliman A, Cheah K. Stability of impaction-grafted hip and knee prostheses: surgical technique, implant design and graft compaction. In: Delloye C, Bannister G, eds. Impaction bone grafting in revision arthroplasty. New York: Marcel Dekker, 2004:75\u201394.","DOI":"10.1201\/9780203913680.ch7"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200111000-00008"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"Reilly D, Walker PS, Ben-Dov M, Ewald FC. Effects of tibial components on load transfer in the upper tibia. Clin Orthop 1982;165:273\u201382.","DOI":"10.1097\/00003086-198205000-00042"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Bourne RB, Finlay JB. The influence of tibial component intramedullary stems and implant-cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty: an in vitro study. Clin Orthop 1986;208:95\u20139.","DOI":"10.1097\/00003086-198607000-00020"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.32457"},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200211000-00026"},{"key":"R21","doi-asserted-by":"crossref","unstructured":"Stern SH, Wills RD, Gilbert JL. The effect of tibial stem design on component micromotion in knee arthroplasty. Clin Orthop 1997;345:44\u201352.","DOI":"10.1097\/00003086-199712000-00008"},{"key":"R22","doi-asserted-by":"crossref","unstructured":"Lee RW, Volz RG, Sheridan DC. The role of fixation and bone quality on the mechanical stability of tibial knee components. Clin Orthop 1991;273:177\u201383.","DOI":"10.1097\/00003086-199112000-00027"},{"key":"R23","unstructured":"Toms AD, McClelland D, Spencer-Jones R. Impaction bone grafting in revision knee surgery: operative technique manual. Leeds: Johnson &\n Johnson, 2002."},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)90009-2"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000058638.94987.20"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1007\/BF00435419"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(07)80036-2"},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2001.25507"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2000.6617"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000063565.90853.a4"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.79B5.0790874"},{"key":"R32","doi-asserted-by":"crossref","unstructured":"Pilliar RM, Lee JM. Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop 1986;208:108\u201313.","DOI":"10.1097\/00003086-198607000-00023"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.75B2.8444949"},{"key":"R34","doi-asserted-by":"crossref","unstructured":"Miura H, Whiteside LA, Easley JC, Amador DD. Effects of screws and a sleeve on initial fixation in uncemented total knee tibial components. Clin Orthop 1990;259:160\u20138.","DOI":"10.1097\/00003086-199010000-00023"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(05)80132-9"},{"key":"R36","doi-asserted-by":"crossref","unstructured":"Volz RG, Nisbet JK, Lee RW, McMurty MG. The mechanical stability of various non-cemented tibial components. Clin Orthop 1988;226:38\u201342.","DOI":"10.1097\/00003086-198801000-00008"},{"key":"R37","doi-asserted-by":"crossref","unstructured":"Kaiser AD, Whiteside LA. The effects of screws and pegs on the initial fixation stability of an uncemented unicondylar knee replacement. Clin Orthop 1990;259:169\u201378.","DOI":"10.1097\/00003086-199010000-00024"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B5.15860","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.87B5.15860","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B5.15860","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:53:24Z","timestamp":1629147204000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.87B5.15860"}},"subtitle":["INITIAL STABILITY AND DESIGN OF THE STEM"],"short-title":[],"issued":{"date-parts":[[2005,5]]},"references-count":37,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2005,5]]}},"alternative-id":["10.1302\/0301-620X.87B5.15860"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.87b5.15860","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,5]]}}}