{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T01:48:39Z","timestamp":1762998519106},"reference-count":28,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"6","license":[{"start":{"date-parts":[[2005,6,1]],"date-time":"2005-06-01T00:00:00Z","timestamp":1117584000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2005,6]]},"abstract":"<jats:p> We investigated the changes in surface roughness of retrieved femoral components in 18 men and four women at revision knee surgery. The mean age at revision was 68.4 years and the mean period of implantation was for 55.6 months. Eighteen implants were retrieved for aseptic loosening and four for infection. The surface changes in the articulating areas were inspected visually and the roughness (Ra) analysed with a profilometer. Parallel scratching and burnishing were the two main forms of damage. The mean Ra measurements in the articulating areas showed no statistically significant difference when compared with those in a control area on either side of the patellar groove at the apex of the femoral flange. This suggests that it is not essential to revise a well-fixed and correctly aligned femoral component where the polished surface has become burnished or bears fine parallel scratches, if the revision is conducted solely for failure of the tibial component. <\/jats:p>","DOI":"10.1302\/0301-620x.87b6.15776","type":"journal-article","created":{"date-parts":[[2005,5,23]],"date-time":"2005-05-23T18:33:29Z","timestamp":1116873209000},"page":"796-799","source":"Crossref","is-referenced-by-count":14,"title":["The significance of surface changes on retrieved femoral components after total knee replacement"],"prefix":"10.1302","volume":"87-B","author":[{"given":"A.","family":"Lakdawala","sequence":"first","affiliation":[{"name":"Holly House Hospital, Buckhurst Hill, Essex IG9 5HX, UK, Sekeikai Hospital 4-2-10 Kouryounaka-machi, Sakai City, Osaka 590-0024, Japan, Bone & Joint Research Unit Royal London Hospital, Whitechapel, London E1 1BB, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Todo","sequence":"additional","affiliation":[{"name":"Holly House Hospital, Buckhurst Hill, Essex IG9 5HX, UK, Sekeikai Hospital 4-2-10 Kouryounaka-machi, Sakai City, Osaka 590-0024, Japan, Bone & Joint Research Unit Royal London Hospital, Whitechapel, London E1 1BB, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Scott","sequence":"additional","affiliation":[{"name":"Holly House Hospital, Buckhurst Hill, Essex IG9 5HX, UK, Sekeikai Hospital 4-2-10 Kouryounaka-machi, Sakai City, Osaka 590-0024, Japan, Bone & Joint Research Unit Royal London Hospital, Whitechapel, London E1 1BB, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"crossref","unstructured":"Kadoya Y, Kobayashi A, Ohashi H. Wear and osteolysis in total joint replacement. Acta Orthop Scand Suppl 1998;278:1\u201316.","DOI":"10.1080\/17453674.1998.11744778"},{"key":"R2","doi-asserted-by":"crossref","unstructured":"Schmalzried TP, Callaghan JJ. Wear in total hip and knee replacements. J Bone Joint Surg [Am] 1999;81-A:115\u201336.","DOI":"10.2106\/00004623-199901000-00016"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Collier JP, Mayor MB, McNamara JL, Surprenant VA, Jensen RE. Analysis of the failure of 122 polyethylene inserts from the uncemented tibial knee components. Clin Orthop 1991;273:232\u201342.","DOI":"10.1097\/00003086-199112000-00034"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Lewis P, Rorabeck CH, Bourne RB, Devane P. Posteromedial tibial polyethylene failure in total knee replacements. Clin Orthop 1994;299:11\u201317.","DOI":"10.1097\/00003086-199402000-00002"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop 1994;299:31\u201343.","DOI":"10.1097\/00003086-199402000-00005"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Wright TM, Rimnac CM, Stulberg SD, et al. Wear of polyethylene in total joint replacements: observations from retrieved PCA knee implants. Clin Orthop 1992;276: 126\u201334.","DOI":"10.1097\/00003086-199203000-00016"},{"key":"R7","doi-asserted-by":"crossref","unstructured":"Feng EL, Stulberg SD, Wixson RL. Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. Clin Orthop 1994;299:60\u201371.","DOI":"10.1097\/00003086-199402000-00008"},{"key":"R8","doi-asserted-by":"crossref","unstructured":"Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop 1989;248:9\u201312.","DOI":"10.1097\/00003086-198911000-00003"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820170510"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(2000)53:1<111::AID-JBM15>3.0.CO;2-Y"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Nasser S, Campbell PA, Kilgus D, Kossovsky N, Amstutz HC. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces: a human retrieval analysis. Clin Orthop 1990;261:171\u201385.","DOI":"10.1097\/00003086-199012000-00020"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1016\/1350-4533(94)90041-8"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B7.0840946"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1016\/S0968-0160(00)00060-0"},{"key":"R15","doi-asserted-by":"crossref","unstructured":"Fisher J, Firkins P, Reeves EA, Hailey JL, Isaac GH. The influence of scratches to the metallic counterfaces on the wear of ultra-high molecular weight polyethylene. Proc Inst Mech Eng [H] 1995;209:263\u20134.","DOI":"10.1243\/PIME_PROC_1995_209_353_02"},{"key":"R16","unstructured":"Reis M, Banks S, Sauer W, Anthony M. Abrasive wear simulation in total knee arthroplasty [abstract]. Trans Orthop Res Soc 1999;24:853."},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(20000605)50:3<322::AID-JBM5>3.0.CO;2-U"},{"key":"R18","unstructured":"McNie CM, Barton DC, Ingham E, et al. Experimental and theoretical predictions of wear particle generation in UHMWPE due to microscopic femoral counterface asperities [abstract]. Trans Orthop Res Soc 1998:23\u201375."},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(199623)33:3<159::AID-JBM6>3.0.CO;2-P"},{"key":"R20","unstructured":"White SE, Whiteside LA, McCarthy DS, Anthony M, Poggie RA. Simulated knee wear with cobalt chromium and oxidized zirconium femoral components. Clin Orthop 1994;309:176\u201384."},{"key":"R21","doi-asserted-by":"crossref","unstructured":"Reis MD, Salehi A, Widding K, Hunter G. Polyethylene wear performance of oxidised zirconium and cobalt-chromium knee components under abrasive conditions. J Bone Joint Surg [Am] 2002;84-A(Suppl 2):129\u201335.","DOI":"10.2106\/00004623-200200002-00018"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1016\/0267-6605(93)90016-Z"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.76B5.8083291"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.85B3.13041"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.3109\/17453679008993587"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B1.1732258"},{"key":"R27","doi-asserted-by":"crossref","unstructured":"Babis GC, Trousdale RT, Morrey BF. The effectiveness of isolated tibial insert exchange in revision total knee arthroplasty. J Bone Joint Surg [Am] 2002;84-A:64\u20138.","DOI":"10.2106\/00004623-200201000-00010"},{"key":"R28","unstructured":"BS 7251-14:1998 orthopaedic joint prostheses. Components for partial and total knee-joint prostheses: articulating surfaces made of metal: ceramic and plastics materials. British Standards Institute."}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B6.15776","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.87B6.15776","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.87B6.15776","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:03:48Z","timestamp":1629144228000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.87B6.15776"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,6]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2005,6]]}},"alternative-id":["10.1302\/0301-620X.87B6.15776"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.87b6.15776","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,6]]}}}