{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T03:42:36Z","timestamp":1785901356709,"version":"3.56.0"},"reference-count":20,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"12","license":[{"start":{"date-parts":[[2006,12,1]],"date-time":"2006-12-01T00:00:00Z","timestamp":1164931200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2006,12]]},"abstract":"<jats:p> The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons. <\/jats:p>","DOI":"10.1302\/0301-620x.88b12.17696","type":"journal-article","created":{"date-parts":[[2006,12,12]],"date-time":"2006-12-12T04:44:57Z","timestamp":1165898697000},"page":"1610-1612","source":"Crossref","is-referenced-by-count":173,"title":["Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures"],"prefix":"10.1302","volume":"88-B","author":[{"given":"M.","family":"Al-Rashid","sequence":"first","affiliation":[{"name":"Birmingam Hand Centre, Selly Oak Hospital, University Hospital Birmingham, Raddlebarn Road, Birmingham B29 6JD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Theivendran","sequence":"additional","affiliation":[{"name":"Birmingam Hand Centre, Selly Oak Hospital, University Hospital Birmingham, Raddlebarn Road, Birmingham B29 6JD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. A. C.","family":"Craigen","sequence":"additional","affiliation":[{"name":"Birmingam Hand Centre, Selly Oak Hospital, University Hospital Birmingham, Raddlebarn Road, Birmingham B29 6JD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1053\/jhsu.2002.32081"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(98)80063-4"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003;27:1\u20136.","DOI":"10.1007\/s00264-002-0393-x"},{"key":"R4","unstructured":"Lowry KJ, Gainor BJ, Hoskins JS. Extensor tendon rupture secondary to the AO\/ASIF titanium distal radius plate without associated plate failure: a case report. Am J Orthop 2000;29:789\u201391."},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1054\/jhsb.2000.0485"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1097\/00000637-200044050-00016"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200503000-00006"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2003.12.010"},{"key":"R9","doi-asserted-by":"crossref","unstructured":"Osada D, Viegas SF, Shah MA, Morris RP, Patterson RM. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg [Am] 2003;28:94\u2013104.","DOI":"10.1053\/jhsu.2003.50016"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2005.10.010"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Gartland JJ Jr, Werley CW. Evaluation of healed Colles\u2019 fractures. J Bone Joint Surg [Am] 1951;33-A:895\u2013902.","DOI":"10.2106\/00004623-195133040-00009"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1053\/jhsu.1999.1279"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.80B2.0800225"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1016\/0266-7681(90)90048-9"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200505000-00003"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.5099"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"Cooney WP 3rd, Dobyns JH, Linscheid RL. Complications of Colles\u2019 fractures. J Bone Joint Surg [Am] 1980;62-A:613\u201319.","DOI":"10.2106\/00004623-198062040-00016"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Lidstrom A. Fractures of the distal end of the radius: a clinical and statistical study of end results. Acta Orthop Scand 1959;41:1\u2013118.","DOI":"10.3109\/ort.1959.30.suppl-41.01"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.3109\/17453679408995434"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Helal B, Chen SC, Iwegbu G. Rupture of the extensor pollicis longus tendon in undisplaced Colles\u2019 type of fracture. Hand 1982;14:41\u20137.","DOI":"10.1016\/S0072-968X(82)80038-7"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.88B12.17696","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.88B12.17696","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.88B12.17696","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:44:30Z","timestamp":1629146670000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.88B12.17696"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,12]]},"references-count":20,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2006,12]]}},"alternative-id":["10.1302\/0301-620X.88B12.17696"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.88b12.17696","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,12]]}}}