{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T09:34:56Z","timestamp":1780047296896,"version":"3.53.1"},"reference-count":37,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"12","license":[{"start":{"date-parts":[[2006,12,1]],"date-time":"2006-12-01T00:00:00Z","timestamp":1164931200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2006,12]]},"abstract":"<jats:p> We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to follow-up. <\/jats:p><jats:p> The rate of revision of the femoral component for aseptic loosening and osteolysis was 1.1% (1 stem), that for revision for any cause was 2.2% (2 stems), and for re-operation for any cause was 21.6% (19 hips). Re-operation was because of failure of the acetabular component in all but two hips. <\/jats:p><jats:p> All but one femoral component subsided within the cement mantle to a mean of 1.52 mm (0 to 8.3) at the final follow-up. One further stem had subsided excessively (8 mm) and had lucent lines at the cement-stem and cement-bone interfaces. This was classified as a radiological failure and is awaiting revision. One stem was revised for deep infection and one for excessive peri-articular osteolysis. Defects of the cement mantle (Barrack grade C and D) were found in 28% of stems (25 hips), associated with increased subsidence (p = 0.01), but were not associated with endosteal lysis or failure. <\/jats:p><jats:p> Peri-articular osteolysis was significantly related to the degree of polyethylene wear (p &lt; 0.001), which was in turn associated with a younger age (p = 0.01) and male gender (p &lt; 0.001). <\/jats:p><jats:p> The use of the Exeter metal-backed acetabular component was a notable failure with 12 of 32 hips (37.5%) revised for loosening. The Harris-Galante components failed with excessive wear, osteolysis and dislocation with 15% revised (5 of 33 hips). Only one of 23 hips with a cemented Elite component (4%) was revised for loosening and osteolysis. <\/jats:p><jats:p> Our findings show that the Exeter Universal stem implanted outside the originating centre has excellent medium-term results. <\/jats:p>","DOI":"10.1302\/0301-620x.88b12.18345","type":"journal-article","created":{"date-parts":[[2006,12,12]],"date-time":"2006-12-12T04:44:57Z","timestamp":1165898697000},"page":"1584-1590","source":"Crossref","is-referenced-by-count":72,"title":["The Exeter Universal stem"],"prefix":"10.1302","volume":"88-B","author":[{"given":"S.","family":"Hook","sequence":"first","affiliation":[{"name":"Avon Orthopaedic Centre, Southmead Hospital, Westbury-on-Trym, Bristol BS10 5NB, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Moulder","sequence":"additional","affiliation":[{"name":"Avon Orthopaedic Centre, Southmead Hospital, Westbury-on-Trym, Bristol BS10 5NB, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. J.","family":"Yates","sequence":"additional","affiliation":[{"name":"University of Western Australia, Fremantle Hospital, Alma Road, Perth 6160, Western Australia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B. J.","family":"Burston","sequence":"additional","affiliation":[{"name":"Avon Orthopaedic Centre, Southmead Hospital, Westbury-on-Trym, Bristol BS10 5NB, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Whitley","sequence":"additional","affiliation":[{"name":"Avon Orthopaedic Centre, Southmead Hospital, Westbury-on-Trym, Bristol BS10 5NB, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. C.","family":"Bannister","sequence":"additional","affiliation":[{"name":"Avon Orthopaedic Centre, Southmead Hospital, Westbury-on-Trym, Bristol BS10 5NB, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","unstructured":"Fowler JL, Gie GA, Lee AJ, Ling RS. Experience with the Exeter total hip replacement since 1970. Orthop Clin North Am 1988;19:477\u201389."},{"key":"R2","unstructured":"Ling RS. The history and development of the Exeter hip. Stryker, UK, 2004."},{"key":"R3","unstructured":"Malchau H, Herberts P, Garellick G, Soderman P, Eisler T. Prognosis of total hip replacements. Procs 69th American Academy of Orthopedic Surgeons annual meeting, 2002."},{"key":"R4","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199810000-00006"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.80B4.0800573"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.75B6.8245072"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B7.0841091"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.01.014"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2474-4-6"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.78B2.0780185"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Johnston RC, Fitzgerald RH Jr, Harris WM, et al. Clinical and radiological evaluation of total hip replacement: a standard system of terminology reporting results. J Bone Joint Surg [Am] 1990;72-A:161\u20138.","DOI":"10.2106\/00004623-199072020-00002"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B3.1587883"},{"key":"R13","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC. \u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141:17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"R14","doi-asserted-by":"crossref","unstructured":"DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976;121:20\u201332.","DOI":"10.1097\/00003086-197611000-00003"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.69B1.3818732"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197355080-00006"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"Latimer HA, Lachiewicz PF. Porous-coated acetabular components with screw fixation: five to ten-year results. J Bone Joint Surg [Am] 1996;78-A:975\u201381.","DOI":"10.2106\/00004623-199607000-00001"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.62B2.7364829"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(03)00336-X"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Madey SM, Callaghan JJ, Olejniczak JP, Goetz DD, Johnston RC. Charnley total hip arthroplasty with use of improved techniques of cementing: the results after a minimum of fifteen years follow-up. J Bone Joint Surg [Am] 1997;79-A:53\u201364.","DOI":"10.2106\/00004623-199701000-00006"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(05)80201-3"},{"key":"R22","doi-asserted-by":"crossref","unstructured":"Oishi CS, Walker RH, Colwell CW Jr. The femoral component in total hip arthroplasty: six to eight-year follow-up of one hundred consecutive patients after use of a third-generation cementing technique. J Bone Joint Surg [Am] 1994;76-A:1130\u20136.","DOI":"10.2106\/00004623-199408000-00003"},{"key":"R23","doi-asserted-by":"crossref","unstructured":"Clohisy JC, Harris WH. Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. J Bone Joint Surg [Am] 1999;81-A:247\u201355.","DOI":"10.2106\/00004623-199902000-00012"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2001.23576"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B7.16079"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.30292"},{"key":"R27","unstructured":"Yates P, Burston B, Bannister G. Collarless Polished Tapered stem (CPT): clinical and radiological follow-up at a minimum of 10 years. J Bone Joint Surg [Am] 2006: in press."},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Kobayashi A, Donnelly W, Scott G, Freeman MA. Early radiological observations may predict the long-term survival of femoral hip prostheses. J Bone Joint Surg [Br] 1997;79-A:583\u20139.","DOI":"10.1302\/0301-620X.79B4.0790583"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.71B3.2722941"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.3109\/17453679908997847"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2001.23920"},{"key":"R32","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820270110"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.73B4.2071634"},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(97)90022-X"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B1.16715"},{"key":"R36","unstructured":"Yates PJ, Quraishi NA, Kop A, et al. Fractures of modern high nitrogen stainless steel cemented stems: cause, mechanism and avoidance in 14 cases. J Arthroplasty 2006: in press."},{"key":"R37","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.02.006"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.88B12.18345","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.88B12.18345","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.88B12.18345","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:43:46Z","timestamp":1629146626000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.88B12.18345"}},"subtitle":["A MINIMUM TEN-YEAR REVIEW FROM AN INDEPENDENT CENTRE"],"short-title":[],"issued":{"date-parts":[[2006,12]]},"references-count":37,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2006,12]]}},"alternative-id":["10.1302\/0301-620X.88B12.18345"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.88b12.18345","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,12]]}}}