{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T18:04:30Z","timestamp":1778609070669,"version":"3.51.4"},"reference-count":13,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"5","license":[{"start":{"date-parts":[[2006,5,1]],"date-time":"2006-05-01T00:00:00Z","timestamp":1146441600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2006,5]]},"abstract":"<jats:p> The object of this study was to develop a method to assess the accuracy of an image-free total knee replacement navigation system in legs with normal or abnormal mechanical axes. A phantom leg was constructed with simulated hip and knee joints and provided a means to locate the centre of the ankle joint. Additional joints located at the midshaft of the tibia and femur allowed deformation in the flexion\/extension, varus\/valgus and rotational planes. Using a digital caliper unit to measure the coordinates precisely, a software program was developed to convert these local coordinates into a determination of actual leg alignment. At specific points in the procedure, information was compared between the digital caliper measurements and the image-free navigation system. Repeated serial measurements were undertaken. In the setting of normal alignment the mean error of the system was within 0.5\u00b0. In the setting of abnormal plane alignment in both the femur and the tibia, the error was within 1\u00b0. This is the first study designed to assess the accuracy of a clinically-validated navigation system. It demonstrates in vitro accuracy of the image-free navigation system in both normal and abnormal leg alignment settings. <\/jats:p>","DOI":"10.1302\/0301-620x.88b5.17431","type":"journal-article","created":{"date-parts":[[2006,4,27]],"date-time":"2006-04-27T19:28:13Z","timestamp":1146166093000},"page":"601-605","source":"Crossref","is-referenced-by-count":71,"title":["Accuracy of a computer-assisted navigation system for total knee replacement"],"prefix":"10.1302","volume":"88-B","author":[{"given":"R. P.","family":"Pitto","sequence":"first","affiliation":[{"name":"Department of Orthopaedics, Middlemore Hospital, 93311 Otahuhu, Auckland, New Zealand."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A. J.","family":"Graydon","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Middlemore Hospital, 93311 Otahuhu, Auckland, New Zealand."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Bradley","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics, Middlemore Hospital, 93311 Otahuhu, Auckland, New Zealand."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. F.","family":"Malak","sequence":"additional","affiliation":[{"name":"Department of Engineering Science"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. G.","family":"Walker","sequence":"additional","affiliation":[{"name":"Department of Engineering Science"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I. A.","family":"Anderson","sequence":"additional","affiliation":[{"name":"Bioengineering Institute, 70 Symonds Street, University of Auckland, New Zealand."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"crossref","unstructured":"Wasielewski RC, Galante JO, Leightly R, Natarajan RN, Rosenberg RG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during arthroplasty. Clin Orthop 1993;299:31\u201343.","DOI":"10.1097\/00003086-199402000-00005"},{"key":"R2","doi-asserted-by":"crossref","unstructured":"Lotke PA, Ecker ML. Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg [Am] 1977;59-A:77\u20139.","DOI":"10.2106\/00004623-197759010-00013"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Crossett LS, Rubash HE. Tibial component position. In: Scuderi GR, Tria AJ, eds. Surgical techniques in total knee arthroplasty. New York: Springer-Verlag, 2002: 243\u201353.","DOI":"10.1007\/0-387-21714-2_33"},{"key":"R4","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.85B6.13722"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Stulberg SD, Loan P, Sarin V. Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg [Am] 2002;84-A(Supp 2):90\u20138.","DOI":"10.2106\/00004623-200200002-00011"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-003-0501-6"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1007\/s10776-002-0623-6"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.85B3.14212"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1016\/S0736-0266(01)00171-1"},{"key":"R10","unstructured":"Slomczykowski M, Edwards PJ, Penney GP. Cadaver study to assess the accuracy of CT-Free Guided Knee Replacement. Trans ORS 2004:1378."},{"key":"R11","unstructured":"Schleicher I, Donnelly W, Crawford R. Results of acetabular component positioning with an imageless hip navigation system, using a mechanical hip device. J Bone Joint Surg [Br] 2004;86-B (Suppl):474."},{"key":"R12","unstructured":"Schleicher I, Nogler M, Donnelly W, Sledge J. Acetabular placement using an imageless navigation system: a cadaver trial. J Bone Joint Surg [Br] 2004;86-B (Suppl):474."},{"key":"R13","doi-asserted-by":"crossref","unstructured":"Donnelly WJ, Crawford RW, Rimmington TD, Whitehouse SL, Whitting KA. Acetabular cup placement: are we accurate? J Bone Joint Surg [Br] 2004;86-B (Suppl):474.","DOI":"10.2106\/00004623-200410000-00030"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.88B5.17431","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.88B5.17431","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.88B5.17431","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:37:19Z","timestamp":1629146239000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.88B5.17431"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,5]]},"references-count":13,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2006,5]]}},"alternative-id":["10.1302\/0301-620X.88B5.17431"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.88b5.17431","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,5]]}}}