{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T07:55:37Z","timestamp":1781337337481,"version":"3.54.1"},"reference-count":28,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"7","license":[{"start":{"date-parts":[[2006,7,1]],"date-time":"2006-07-01T00:00:00Z","timestamp":1151712000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2006,7]]},"abstract":"<jats:p> A modular layered acetabular component (metal-polyethylene-ceramic) was developed in Japan for use in alumina ceramic-on-ceramic total hip replacement. Between May 1999 and July 2000, we performed 35 alumina ceramic-on-ceramic total hip replacements in 30 consecutive patients, using this layered component and evaluated the clinical and radiological results over a mean follow-up of 5.8 years (5 to 6.5). A total of six hips underwent revision, one for infection, two for dislocation with loosening of the acetabular component, two for alumina liner fractures and one for component dissociation with pelvic osteolysis. There were no fractures of the ceramic heads, and no loosening of the femoral or acetabular component in the unrevised hips was seen at final follow-up. Osteolysis was not observed in any of the unrevised hips. The survivorship analysis at six years after surgery was 83%. The layered acetabular component in our experience, has poor durability because of unexpected mechanical failures including alumina liner fracture and component dissociation. <\/jats:p>","DOI":"10.1302\/0301-620x.88b7.17675","type":"journal-article","created":{"date-parts":[[2006,6,23]],"date-time":"2006-06-23T19:55:49Z","timestamp":1151092549000},"page":"877-882","source":"Crossref","is-referenced-by-count":50,"title":["Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component"],"prefix":"10.1302","volume":"88-B","author":[{"given":"M.","family":"Hasegawa","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Mie University Graduate, School of Medicine, 2-174, Edobashi, Tsu City, Mie 514-8507, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Sudo","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Mie University Graduate, School of Medicine, 2-174, Edobashi, Tsu City, Mie 514-8507, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Uchida","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Mie University Graduate, School of Medicine, 2-174, Edobashi, Tsu City, Mie 514-8507, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"crossref","unstructured":"Nizard RS, Sedel L, Christel P, et al. Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop 1992;282:53\u201363.","DOI":"10.1097\/00003086-199209000-00007"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.76B1.8300682"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(99)90225-5"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Sedel L, Nizard RS, Kerboull L, Witvoet J. Alumina-alumina hip replacement in patients younger than 50 years old. Clin Orthop 1994;298:175\u201383.","DOI":"10.1097\/00003086-199401000-00023"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200212000-00019"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg [Am] 2002;84-A:69\u201377.","DOI":"10.2106\/00004623-200201000-00011"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200010000-00017"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(19970605)35:3<287::AID-JBM3>3.0.CO;2-D"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-195436030-00001"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976;121:20\u201332.","DOI":"10.1097\/00003086-197611000-00003"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC. \u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141:17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"R12","doi-asserted-by":"crossref","unstructured":"Hodgkinson JP, Shelley P, Wroblewski BM. The correlation between the roent-genographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop 1988;228:105\u20139.","DOI":"10.1097\/00003086-198803000-00016"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.69B1.3818732"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199072040-00008"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197355080-00006"},{"key":"R16","doi-asserted-by":"crossref","unstructured":"Hasegawa M, Sudo A, Uchida A. Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture: a case report. Acta Orthopaedica 2006:in press.","DOI":"10.1080\/17453670610013088"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"D\u2019Antonio J, Capello W, Manley M, Naughton M, Sutton K. Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop 2005;436:164\u201371.","DOI":"10.1097\/01.blo.0000162995.50971.39"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Yoo JJ, Kim YM, Yoon KS, et al. Alumina-on-alumina total hip arthroplasty: a five-year minimum follow-up study. J Bone Joint Surg [Am] 2005;87-A:530\u20135.","DOI":"10.2106\/JBJS.D.01753"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(03)00193-1"},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.02.027"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1080\/00016470410001312-1"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199607000-00021"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200010000-00004"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200010000-00007"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.3109\/17453679808997776"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2000.8100"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-001-0378-z"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Allain J, Roudot-Thoraval F, Delecrin J, et al. Revision total hip arthroplasty performed after fracture of a ceramic femoral head: a multicenter survivorship study. J Bone Joint Surg [Am] 2003;85-A:825\u201330.","DOI":"10.2106\/00004623-200305000-00009"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.88B7.17675","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.88B7.17675","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.88B7.17675","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:57:27Z","timestamp":1629147447000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.88B7.17675"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,7]]},"references-count":28,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2006,7]]}},"alternative-id":["10.1302\/0301-620X.88B7.17675"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.88b7.17675","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,7]]}}}