{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T05:14:11Z","timestamp":1789535651284,"version":"build-2803163510"},"reference-count":30,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"10","license":[{"start":{"date-parts":[[2007,10,1]],"date-time":"2007-10-01T00:00:00Z","timestamp":1191196800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2007,10]]},"abstract":"<jats:p> We compared the results of 146 patients who received an anatomic modular knee fixed-bearing total knee replacement (TKR) in one knee and a low contact stress rotating platform mobile-bearing TKR in the other. There were 138 women and eight men with a mean age of 69.8 years (42 to 80). The mean follow-up was 13.2 years (11.0 to 14.5). The patients were assessed clinically and radiologically using the rating systems of the Hospital for Special Surgery and the Knee Society at three months, six months, one year, and annually thereafter. <\/jats:p><jats:p> The assessment scores of both rating systems pre-operatively and at the final review did not show any statistically significant differences between the two designs of implant. In the anatomic modular knee group, one knee was revised because of aseptic loosening of the tibial component and one because of infection. In addition, three knees were revised because of wear of the polyethylene tibial bearing. In the low contact stress group, two knees were revised because of instability requiring exchange of the polyethylene insert and one because of infection. <\/jats:p><jats:p> The radiological analysis found no statistical difference in the incidence of radiolucent lines at the final review (Student\u2019s t-test, p = 0.08), most of which occurred at tibial zone 1. The Kaplan-Meier survivorship for aseptic loosening of the anatomic modular knee and the low contact stress implants at 14.5 years was 99% and 100%, respectively, with a 95% confidence interval of 94% to 100% for both designs. <\/jats:p><jats:p> We found no evidence of the superiority of one design over the other at long-term follow-up. <\/jats:p>","DOI":"10.1302\/0301-620x.89b10.19223","type":"journal-article","created":{"date-parts":[[2007,10,23]],"date-time":"2007-10-23T19:51:55Z","timestamp":1193169115000},"page":"1317-1323","source":"Crossref","is-referenced-by-count":83,"title":["The long-term results of simultaneous fixed-bearing and mobile-bearing total knee replacements performed in the same patient"],"prefix":"10.1302","volume":"89-B","author":[{"given":"Y.-H.","family":"Kim","sequence":"first","affiliation":[{"name":"The Joint Replacement Center of Korea, Ewha Womans University Dong Dae Mun Hospital, 70, ChongRo 6-Ga, ChongRo-Gu, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.-H.","family":"Yoon","sequence":"additional","affiliation":[{"name":"The Joint Replacement Center of Korea, Ewha Womans University Dong Dae Mun Hospital, 70, ChongRo 6-Ga, ChongRo-Gu, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.-S.","family":"Kim","sequence":"additional","affiliation":[{"name":"The Joint Replacement Center of Korea, Ewha Womans University Dong Dae Mun Hospital, 70, ChongRo 6-Ga, ChongRo-Gu, Seoul, Korea."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B1.17864"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B8.15772"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Collier MB, Engh CA Jr, MCauley JP, Ginn SD, Engh A. Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert: findings at five to ten years post-operatively. J Bone Joint Surg [Am] 2005;87-A:2702\u20138.","DOI":"10.2106\/00004623-200512000-00014"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Conditt MA, Stein JA, Noble PC. Factors affecting the severity of backside wear of modular tibial inserts. J Bone Joint Surg [Am] 2004;86-A:305\u201311.","DOI":"10.2106\/00004623-200402000-00013"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Conditt MA, Thompson MT, Usrey MM, Ismaily SK, Noble PC. Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss. J Bone Joint Surg [Am] 2005;87-A:326\u201331.","DOI":"10.2106\/00004623-200502000-00014"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Lachiewicz PF, Soileau ES. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement: results at five to fourteen years. J Bone Joint Surg [Am] 2004;86-A:525\u201330.","DOI":"10.2106\/00004623-200403000-00010"},{"key":"R7","doi-asserted-by":"crossref","unstructured":"Mikulak SA, Mahoney OM, de la Rosa MA, Schmalzried TP. Loosening and osteolysis with press-fit condylar posterior-cruciate-substituting total knee replacement. J Bone Joint Surg [Am] 2001;83-A:398\u2013403.","DOI":"10.2106\/00004623-200103000-00012"},{"key":"R8","doi-asserted-by":"crossref","unstructured":"O\u2019Rourke MR, Callaghan JJ, Goetz DD, Sullivan PM, Johnston RC. Osteolysis associated with a cemented modular posterior-cruciate-substituting total knee design: five to eight-year follow-up. J Bone Joint Surg [Am] 2002;84-A:1362\u201371.","DOI":"10.2106\/00004623-200208000-00012"},{"key":"R9","doi-asserted-by":"crossref","unstructured":"Rao AR, Engh GA, Collier MB, Lounici S. Tibial interface wear in retrieved total knee components and correlations with modular insert motion. J Bone Joint Surg [Am] 2002;84-A:1849\u201355.","DOI":"10.2106\/00004623-200210000-00017"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Bartel DL, Bicknel VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg [Am] 1986;68-A:1041\u201351.","DOI":"10.2106\/00004623-198668070-00010"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199011000-00027"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B1.1732233"},{"key":"R13","doi-asserted-by":"crossref","unstructured":"O\u2019Connor JJ, Goodfellow JW. Theory and practice of meniscal knee replacement: designing against wear. Proc Inst Mech Eng [H] 1996;210:217\u201322.","DOI":"10.1243\/PIME_PROC_1996_210_415_02"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200111000-00013"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.85B1.13233"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1055\/s-2005-836828"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"Insall JN, Ranawat CS, Aglietti P, Shine J. A comparison of four models of total knee-replacement prostheses. J Bone Joint Surg [Am] 1976;58-A:754\u201365.","DOI":"10.2106\/00004623-197658060-00003"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop 1989;248:13\u201314.","DOI":"10.1097\/00003086-198911000-00004"},{"key":"R19","doi-asserted-by":"crossref","unstructured":"Tegner Y, Lysholm J. Rating systems in the evaluation of knee ligament injuries. Clin Orthop 1985;198:43\u20139.","DOI":"10.1097\/00003086-198509000-00007"},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1080\/01621459.1958.10501452"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2003.10.004"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B7.18635"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200107000-00008"},{"key":"R24","unstructured":"Buechel FF, Buechel FF, Pappas MJ, D\u2019Alessio J. Twenty-year evaluation of the New Jersey LCS rotating platform knee replacement. J Knee Surg 2002;15:84\u20139."},{"key":"R25","doi-asserted-by":"crossref","unstructured":"Werner F, Foster D, Murray DG. The influence of design on the transmission of torque across knee prostheses. J Bone Joint Surg [Am] 1978;60-A:342\u20138.","DOI":"10.2106\/00004623-197860030-00012"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200408000-00029"},{"key":"R27","doi-asserted-by":"crossref","unstructured":"Bert JM. Dislocation\/subluxation of meniscal bearing elements after New Jersey low-contact stress total knee arthroplasty. Clin Orthop 1990;254:211\u201315.","DOI":"10.1097\/00003086-199005000-00030"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Weaver JK, Derkash RS, Greenwald AS. Difficulties with bearing dislocation and breakage using a movable bearing total knee replacement system. Clin Orthop 1993;290:244\u201352.","DOI":"10.1097\/00003086-199305000-00031"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B8.17529"},{"key":"R30","unstructured":"Beverland D. Management of the severe varus and valgus knee using the low contact stress rotating platform. Orthopedics 2006;29(9Suppl):60\u20133."}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.89B10.19223","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.89B10.19223","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.89B10.19223","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:25:43Z","timestamp":1629145543000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.89B10.19223"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,10]]},"references-count":30,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2007,10]]}},"alternative-id":["10.1302\/0301-620X.89B10.19223"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.89b10.19223","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,10]]}}}