{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T02:14:28Z","timestamp":1776132868598,"version":"3.50.1"},"reference-count":38,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"11","license":[{"start":{"date-parts":[[2007,11,1]],"date-time":"2007-11-01T00:00:00Z","timestamp":1193875200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2007,11]]},"abstract":"<jats:p> We have evaluated four different fixation techniques for the reconstruction of a standard Mason type-III fracture of the radial head in a sawbone model. The outcome measurements were the quality of the reduction, and stability. <\/jats:p><jats:p> A total of 96 fractures was created. Six surgeons were involved in the study and each reconstructed 16 fractures with 1.6 mm fine-threaded wires (Fragment Fixation System (FFS)), T-miniplates, 2 mm miniscrews and 2 mm Kirschner (K-) wires; four fractures being allocated to each method using a standard reconstruction procedure. <\/jats:p><jats:p> The quality of the reduction was measured after definitive fixation. Biomechanical testing was performed using a transverse plane shear load in two directions to the implants (parallel and perpendicular) with respect to ultimate failure load and displacement at 50 N. <\/jats:p><jats:p> A significantly better quality of reduction was achieved using the FFS wires (Tukey\u2019s post hoc tests, p &lt; 0.001) than with the other devices with a mean step in the articular surface and the radial neck of 1.04 mm (sd 0.96) for the FFS, 4.25 mm (sd 1.29) for the miniplates, 2.21 mm (sd 1.06) for the miniscrews and 2.54 mm (sd 0.98) for the K-wires. The quality of reduction was similar for K-wires and miniscrews, but poor for miniplates. <\/jats:p><jats:p> The ultimate failure load was similar for the FFS wires (parallel, 196.8 N (sd 46.8), perpendicular, 212.5 N (sd 25.6)), miniscrews (parallel, 211.8 N (sd 47.9), perpendicular, 208.0 N (sd 65.9)) and K-wires (parallel, 200.4 N (sd 54.5), perpendicular, 165.2 N (sd 37.9)), but significantly worse (Tukey\u2019s post hoc tests, p &lt; 0.001) for the miniplates (parallel, 101.6 N (sd 43.1), perpendicular, 122.7 N (sd 40.7)). There was a significant difference in the displacement at 50 N for the miniplate (parallel, 4.8 mm (sd 2.8), perpendicular, 4.8 mm (sd 1.7)) vs FFS (parallel, 2.1 mm (sd 0.8), perpendicular, 1.9 mm (sd 0.7)), miniscrews (parallel, 1.8 mm (sd 0.5), perpendicular, 2.3 mm (sd 0.8)) and K-wires (parallel, 2.2 mm (sd 1.8), perpendicular, 2.4 mm (sd 0.7; Tukey\u2019s post hoc tests, p &lt; 0.001)). <\/jats:p><jats:p> The fixation of a standard Mason type-III fracture in a sawbone model using the FFS system provides a better quality of reduction than that when using conventional techniques. There was a significantly better stability using FFS implants, miniscrews and K-wires than when using miniplates. <\/jats:p>","DOI":"10.1302\/0301-620x.89b11.19433","type":"journal-article","created":{"date-parts":[[2007,11,12]],"date-time":"2007-11-12T03:27:42Z","timestamp":1194838062000},"page":"1545-1550","source":"Crossref","is-referenced-by-count":41,"title":["Reconstruction of a Mason type-III fracture of the radial head using four different fixation techniques"],"prefix":"10.1302","volume":"89-B","author":[{"given":"T. C.","family":"Koslowsky","sequence":"first","affiliation":[{"name":"Department of Surgery, St. Elisabeth Hospital, Werthmannstrasse 1, D-50935 Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Mader","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedic Surgery, Hand and Reconstructive Surgery, St. Vinzenz Hospital, Merheimerstrasse 221-223, D-50733 Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Dargel","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedic Surgery, Hand and Reconstructive Surgery, St. Vinzenz Hospital, Merheimerstrasse 221-223, D-50733 Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Koebke","sequence":"additional","affiliation":[{"name":"Department of Anatomy, University of Cologne, Joseph-Stelzmann-Strasse 9, D-50937 Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Hellmich","sequence":"additional","affiliation":[{"name":"Institute of Medical Statistics, Informatics and Epidemiology, University of Cologne, Kerpener Strasse 62, D-50937 Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Pennig","sequence":"additional","affiliation":[{"name":"Department of Trauma and Orthopaedic Surgery, Hand and Reconstructive Surgery, St. Vinzenz Hospital, Merheimerstrasse 221-223, D-50733 Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.18004217203"},{"key":"R2","doi-asserted-by":"crossref","unstructured":"Broberg MA, Morrey BF. Results of delayed excision of the radial head after fracture. J Bone Joint Surg [Am] 1986;68-A:669\u201374.","DOI":"10.2106\/00004623-198668050-00005"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Herbertsson P, Josefsson PO, Hasserius R, et al. Fractures of the radial head treated with radial head excision. J Bone Joint Surg [Am] 2004;86-A:1925\u201330.","DOI":"10.2106\/00004623-200409000-00010"},{"key":"R4","doi-asserted-by":"publisher","DOI":"10.1007\/BF00419939"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.85B7.13823"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Mikic ZD, Vukadinovic SM. Late results in fractures of the radial head treated with excision. Clin Orthop 1983;181:220\u20138.","DOI":"10.1097\/00003086-198312000-00034"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2004.06.001"},{"key":"R8","doi-asserted-by":"crossref","unstructured":"Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y. Comminuted fractures of the radial head: comparison of resection and internal fixation. J Bone Joint Surg [Am] 2005;87-A:76\u201384.","DOI":"10.2106\/00004623-200501000-00011"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2007.02.016"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Coleman DA, Blair WF, Shurr D. Resection of the radial head for fractures of the radial head. J Bone Joint Surg [Am] 1987;69-A:385\u201392.","DOI":"10.2106\/00004623-198769030-00010"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2004.06.003"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1055\/s-2002-24254"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1016\/j.main.2004.11.009"},{"key":"R14","doi-asserted-by":"crossref","unstructured":"Ring D, Quintero J, Jupiter JB. Open reduction and internal fixation of the fractures of the radial head. J Bone Joint Surg [Am] 2002;84-A:1811\u201315.","DOI":"10.2106\/00004623-200210000-00011"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B6.17415"},{"key":"R16","doi-asserted-by":"crossref","unstructured":"Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ. Comminuted radial head fractures treated with a modular metallic radial head arthroplasty: study of outcomes. J Bone Joint Surg [Am] 2006;88-A:2192\u2013200.","DOI":"10.2106\/00004623-200610000-00011"},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(03)00426-X"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199509040-00008"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-199701000-00001"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Pomianowski S, Morrey BF, Neale PG, et al. Contribution of monoblock and bipolar radial head prostheses to valgus stability of the elbow. J Bone Joint Surg [Am] 2001;12-A:1830\u20134.","DOI":"10.2106\/00004623-200112000-00010"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1080\/17453670610013565"},{"key":"R22","unstructured":"R\u00fcedi TP, Buckley RE, Moran CG. AO principles of fracture management: specific fractures. Vol 2. Davos Platz: AO Publishing 2007."},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2004.01.003"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2005.10.010"},{"key":"R25","doi-asserted-by":"crossref","unstructured":"Rehm KE, Helling HJ, Gatzka C. Neue Entwicklungen beim Einsatz resorbierbarer implantate. Orthop\u00e4de 1997;26:489\u201397 (in German).","DOI":"10.1007\/s001320050116"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200006000-00009"},{"key":"R27","doi-asserted-by":"crossref","unstructured":"Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y. Comminuted fractures of the radial head: comparison of resection and internal fixation: surgical technique. J Bone Joint Surg [Am] 2006;88-A(Suppl):11\u201323.","DOI":"10.2106\/00004623-200603001-00002"},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1016\/S1058-2746(99)90079-4"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-007-0197-1"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1016\/S1067-2516(98)80091-4"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.03.022"},{"key":"R32","doi-asserted-by":"crossref","unstructured":"Odenheimer K, Harvey PJ. Internal fixation of the head of the radius. J Bone Joint Surg [Am] 1979;61-A:785\u201387.","DOI":"10.2106\/00004623-197961050-00028"},{"key":"R33","doi-asserted-by":"crossref","unstructured":"Gausepohl T, Pennig D. The fragment fixation system in intra-articular and peri-articular fractures. In: De Bastiani G, Apley AG, Goldberg A, eds. Orthofix external fixation in trauma and orthopaedics. London: Springer-Verlag, 2000:375\u201395.","DOI":"10.1007\/978-1-4471-0691-3_34"},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1067\/mse.2001.109558"},{"key":"R35","doi-asserted-by":"crossref","unstructured":"Lyons FA, Rockwood CA Jr. Migration of pins used in operation of the shoulder. J Bone Joint Surg [Am] 1990;72-A:1262\u20137.","DOI":"10.2106\/00004623-199072080-00023"},{"key":"R36","doi-asserted-by":"publisher","DOI":"10.1097\/01.ta.0000240443.61205.96"},{"key":"R37","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200008000-00007"},{"key":"R38","doi-asserted-by":"crossref","unstructured":"Gausepohl T, M\u00f6hring R, Pennig D, Koebke J. Fine thread versus coarse thread: a comparison of the maximum holding power. Injury 2001;32(Suppl 4):1\u20137.","DOI":"10.1016\/S0020-1383(01)00168-1"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.89B11.19433","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.89B11.19433","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.89B11.19433","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:26:36Z","timestamp":1629145596000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.89B11.19433"}},"subtitle":["AN EXPERIMENTAL STUDY"],"short-title":[],"issued":{"date-parts":[[2007,11]]},"references-count":38,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2007,11]]}},"alternative-id":["10.1302\/0301-620X.89B11.19433"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.89b11.19433","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,11]]}}}