{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T15:40:10Z","timestamp":1715960410548},"reference-count":52,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"7","license":[{"start":{"date-parts":[[2007,7,1]],"date-time":"2007-07-01T00:00:00Z","timestamp":1183248000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2007,7]]},"abstract":"<jats:p>This study explored the relationship between the initial stability of the femoral component and penetration of cement into the graft bed following impaction allografting.<\/jats:p><jats:p>Impaction allografting was carried out in human cadaveric femurs. In one group the cement was pressurised conventionally but in the other it was not pressurised. Migration and micromotion of the implant were measured under simulated walking loads. The specimens were then cross-sectioned and penetration of the cement measured.<\/jats:p><jats:p>Around the distal half of the implant we found approximately 70% and 40% of contact of the cement with the endosteum in the pressure and no-pressure groups, respectively. The distal migration\/micromotion, and valgus\/varus migration were significantly higher in the no-pressure group than in that subjected to pressure. These motion components correlated negatively with the mean area of cement and its contact with the endosteum.<\/jats:p><jats:p>The presence of cement at the endosteum appears to play an important role in the initial stability of the implant following impaction allografting.<\/jats:p>","DOI":"10.1302\/0301-620x.89b7.18717","type":"journal-article","created":{"date-parts":[[2007,8,2]],"date-time":"2007-08-02T17:54:42Z","timestamp":1186077282000},"page":"962-970","source":"Crossref","is-referenced-by-count":7,"title":["Cement penetration and primary stability of the femoral component after impaction allografting"],"prefix":"10.1302","volume":"89-B","author":[{"given":"C.","family":"Albert","sequence":"first","affiliation":[{"name":"Division of Orthopaedic Engineering Research"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Patil","sequence":"additional","affiliation":[{"name":"Southern General Hospital, 1345 Govan Road, Glasgow GS14 4TP, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Frei","sequence":"additional","affiliation":[{"name":"Division of Orthopaedic Engineering Research"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Masri","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Duncan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Oxland","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Fernlund","sequence":"additional","affiliation":[{"name":"Department of Materials Engineering, University of British Columbia, 910 West 10th Avenue, Vancouver, British Columbia V5Z 4E3, Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.75B1.8421012"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-5898(05)70327-8"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(00)90088-3"},{"key":"R4","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2001.29136"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Ornstein E, Atroshi I, Franzen H, et al.Early complications after one hundred and forty-four consecutive hip revisions with impacted morselized allograft bone and cement. J Bone Joint Surg [Am] 2002;84-A:1323\u20138.","DOI":"10.2106\/00004623-200208000-00006"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Schreurs BW, Arts JJ, Verdonschot N, et al.Femoral component revision with use of impaction bone-grafting and a cemented polished stem. J Bone Joint Surg [Am] 2005;87-A:2499\u2013507.","DOI":"10.2106\/00004623-200511000-00018"},{"key":"R7","doi-asserted-by":"crossref","unstructured":"Masterson EL, Duncan CP.Subsidence and the cement mantle in femoral impaction allografting. Orthopedics 1997;20:821\u20132.","DOI":"10.3928\/0147-7447-19970901-22"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(97)90176-5"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1080\/000164700317413094"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B4.0840544"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.81B1.0810135"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.34532"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.78B6.0780973"},{"key":"R14","doi-asserted-by":"crossref","unstructured":"Gokhale S, Soliman A, Dantas JP, et al.Variables affecting initial stability of impaction grafting for hip revision. Clin Orthop 2005;432:174\u201380.","DOI":"10.1097\/01.blo.0000150103.75134.10"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(97)90005-X"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1016\/j.orthres.2005.03.021.1100230606"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"Meding JB, Ritter MA, Keating EM, Faris PM.Impaction bone-grafting before insertion of a femoral stem with cement in revision total hip arthroplasty: a minimum two-year follow-up study. J Bone Joint Surg [Am] 1997;79-A:1834\u201341.","DOI":"10.2106\/00004623-199712000-00009"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Cabanela ME, Trousdale RT, Berry DJ.Impacted cancellous graft plus cement in hip revision. Clin Orthop 2003;417:175\u201382.","DOI":"10.1097\/01.blo.0000096817.78689.ac"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1080\/000164700317362154"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Nelissen RG, Bauer TW, Weidenhielm LR, LeGolvan DP, Mikhail WE.Revision hip arthroplasty with the use of cement and impaction grafting: histological analysis of four cases. J Bone Joint Surg [Am] 1995;77-A:412\u201322.","DOI":"10.2106\/00004623-199503000-00011"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.86B5.14016"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.12.010"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1016\/j.orthres.2004.05.012"},{"key":"R24","doi-asserted-by":"crossref","unstructured":"Engelbrecht E, Heinert K.Klassifikation und behandlungsrichtlienen von knochen-substanzverlusten bei revisionoperationen am huftgelenk: mittelfristige ergebnisse. In: Prim\u00e4r- und revisions-alloarthroplastik, h\u00fcft- und kniegelenk: Hamburg: Endo-Klinik Berlin: Springer Verlag, 1987:198\u2013201.","DOI":"10.1007\/978-3-642-71832-8_20"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(01)00040-9"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100110518"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200201000-00034"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Pilliar RM, Lee JM, Maniatopoulos C.Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop 1986;208:108\u201313.","DOI":"10.1097\/00003086-198607000-00023"},{"key":"R29","doi-asserted-by":"crossref","unstructured":"Engh CA, O\u2019Connor D, Jasty M, et al.Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop 1992;285:13\u201329.","DOI":"10.1097\/00003086-199212000-00005"},{"key":"R30","doi-asserted-by":"crossref","unstructured":"Jasty M, Bragdon C, Burke D, et al.In vivo skeletal responses to porous-surfaced implants subjected to small induced motions. J Bone Joint Surg [Am] 1997;79-A:707\u201314.","DOI":"10.2106\/00004623-199705000-00010"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(03)00191-X"},{"key":"R32","doi-asserted-by":"crossref","unstructured":"Majkowski RS, Bannister GC, Miles AW.The effect of bleeding on the cement-bone interface: an experimental study. Clin Orthop 1994;299:293\u20137.","DOI":"10.1097\/00003086-199402000-00040"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.81B6.0811052"},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(00)00156-1"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2003.12.002"},{"key":"R36","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.81B1.0810118"},{"key":"R37","doi-asserted-by":"crossref","unstructured":"Dunlop DG, Brewster NT, Madabhushi SP, et al.Techniques to improve the shear strength of impacted bone graft: the effect of particle size and washing of the graft. J Bone Joint Surg [Am] 2003;85-A:639\u201346.","DOI":"10.2106\/00004623-200304000-00009"},{"key":"R38","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200108000-00018"},{"key":"R39","doi-asserted-by":"publisher","DOI":"10.1080\/000164700317393349"},{"key":"R40","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(97)90155-8"},{"key":"R41","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.01.009"},{"key":"R42","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(96)80100-8"},{"key":"R43","doi-asserted-by":"crossref","unstructured":"Hostner J, Hultmark P, Karrholm J, Malchau H, Tveit M.Impaction technique and graft treatment in revisions of the femoral component: laboratory studies and clinical validation. J Arthroplasty 2001;16:76\u201382.","DOI":"10.1054\/arth.2001.9830"},{"key":"R44","doi-asserted-by":"publisher","DOI":"10.1080\/00016470310017938"},{"key":"R45","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(03)00013-7"},{"key":"R46","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B2.14749"},{"key":"R47","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2005.05.013"},{"key":"R48","doi-asserted-by":"publisher","DOI":"10.1080\/000164701753532790"},{"key":"R49","doi-asserted-by":"publisher","DOI":"10.1080\/00016470410001240"},{"key":"R50","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2005.03.007"},{"key":"R51","doi-asserted-by":"publisher","DOI":"10.1007\/s004020050221"},{"key":"R52","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.29393"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.89B7.18717","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.89B7.18717","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.89B7.18717","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,13]],"date-time":"2023-05-13T17:27:21Z","timestamp":1683998841000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.89B7.18717"}},"subtitle":["A BIOMECHANICAL STUDY IN THE CADAVERIC FEMUR"],"short-title":[],"issued":{"date-parts":[[2007,7]]},"references-count":52,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2007,7]]}},"alternative-id":["10.1302\/0301-620X.89B7.18717"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.89b7.18717","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,7]]}}}