{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T01:34:26Z","timestamp":1793756066772,"version":"4.6.1"},"reference-count":30,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"8","license":[{"start":{"date-parts":[[2007,8,1]],"date-time":"2007-08-01T00:00:00Z","timestamp":1185926400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2007,8]]},"abstract":"<jats:p> We carried out a prospective study over a period of 12 months to measure the exposure to radiation of the hands of a dedicated foot and ankle surgeon. A thermoluminescent dosimeter ring (TLD) was used to measure the cumulative dose of radiation. Fluoroscopy was used in operations on the foot and ankle. The total screening time was 3028 s, with a mean time per procedure of 37.4 s (0.6 to 197). This correlated positively with the number of procedures performed (r = 0.92, p &lt; 0.001), and with the dose of radiation in both the left (r = 0.85, p = 0.0005) and right TLDs (r = 0.59, p = 0.419). There was no significant difference in the dose of radiation between the two hands (t-test, p = 0.62). The total dose to the right TLD over the 12 months was 2.4 millisieverts. <\/jats:p><jats:p> This is a simple and convenient method for evaluating the exposure of a single surgeon to radiation. The radiation detected was well below the annual dose limit set by the International Commission on Radiological Protection. <\/jats:p>","DOI":"10.1302\/0301-620x.89b8.19529","type":"journal-article","created":{"date-parts":[[2007,9,4]],"date-time":"2007-09-04T23:17:52Z","timestamp":1188947872000},"page":"1060-1063","source":"Crossref","is-referenced-by-count":23,"title":["Measurement of the dose of radiation to the surgeon during surgery to the foot and ankle"],"prefix":"10.1302","volume":"89-B","author":[{"given":"P. J.","family":"Singh","sequence":"first","affiliation":[{"name":"Nuffield Orthopaedic Centre, Windmill Road, Headington, Oxford OX3 7LD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N. S.","family":"Perera","sequence":"additional","affiliation":[{"name":"Heatherwood & Wexham Park NHS Trust, Wexham, Slough, Berkshire SL2 4HL, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Dega","sequence":"additional","affiliation":[{"name":"Heatherwood & Wexham Park NHS Trust, Wexham, Slough, Berkshire SL2 4HL, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","unstructured":"Christensen EE, Curry TS, Dowdy JE. An introduction to the physics of diagnostic radiology. Philadelphia: Lea and Febiger, 1978:10\u201335."},{"key":"R2","unstructured":"Devalia KL, Guha A, Devadoss VG. The need to protect the thyroid gland during image intensifier use in orthopaedic procedures. Acta Orthop Belg 2004;70:474\u20137."},{"key":"R3","unstructured":"Smith GL, Briggs TW, Lavy CB, Nordeen H. Ionising radiation: are orthopaedic surgeons at risk? Ann R Coll Surg Engl 1992;74:326\u20138."},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Miller ME, Davis ML, MacClean CR, et al. Radiation exposure and associated risks to operating-room personnel during use of fluoroscopic guidance for selected orthopaedic surgical procedures. J Bone Joint Surg [Am] 1983;65-A:1\u20134.","DOI":"10.2106\/00004623-198365010-00001"},{"key":"R5","unstructured":"Bushong SC. Late effects of radiation. In: Radiologic Science for Technologists. St Louis, Mosby, 1998:533\u201349."},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1038\/sj.onc.1207896"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200006000-00015"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1259\/0007-1285-58-689-419"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1259\/0007-1285-55-652-272"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Theocharopoulos N, Perisinakis K, Damilakis J, et al. Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. J Bone Joint Surg [Am] 2003;85-A:1698\u2013703.","DOI":"10.2106\/00004623-200309000-00007"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1148\/101.3.669"},{"key":"R12","unstructured":"Brown M, Greenberg LH. Fluoroscopic measurement in Saskatchewan. J Can Assoc Radiol 1981;32:118\u201320."},{"key":"R13","unstructured":"Taylor KW, Patt NL, Johns HE. Variations in x-ray exposures to patients. J Can Assoc Radiol 1979;30:6\u201311."},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.75B1.8421031"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199708000-00002"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1259\/0007-1285-66-790-899"},{"key":"R17","unstructured":"No authors listed. Landauer File. http:\/\/landauerinc.com (date last accessed 25 July 2007)."},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1016\/0146-6453(91)90065-O"},{"key":"R19","unstructured":"Smith GL, Wakeman R, Briggs TW. Radiation exposure of orthopaedic trainees: quantifying the risk. J R Coll Surg Edinb 1996;41:132\u20134."},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1016\/0091-7435(80)90079-1"},{"key":"R21","unstructured":"No authors listed.National Council on Radiation Protection and Measurements. Exposure of the population in the United States and Canada from natural background radiation. Bethesda, MD: NCRP Report 94, 1988. http:\/\/www.ncrp.com\/ncrprpts.html (date last accessed 28 June 2007). http:\/\/www.ncrponline.org (date last accessed 20 July 2007)."},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1119\/1.2339571"},{"key":"R23","unstructured":"Cohen BL. Concepts of nuclear physics. New York: McGraw-Hill, 1971."},{"key":"R24","doi-asserted-by":"crossref","unstructured":"Cohen BL. Before it\u2019s too late: a scientist\u2019s case for nuclear energy. New York: Plenum Press, 1983.","DOI":"10.1007\/978-1-4684-4577-0"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1080\/09553008814550391"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.138.1.7005937"},{"key":"R27","unstructured":"Bushberg JT, Seibert JA, Lightholdt EM Jr, Boon JM. The essential physics of medical imaging. Baltimore MD, Williams &\n Wilkins, 1994:52\u2013759."},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-726X(199908)47:4<469::AID-CCD18>3.0.CO;2-X"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1148\/104.3.679"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1016\/S0020-1383(98)00090-4"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.89B8.19529","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.89B8.19529","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.89B8.19529","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T20:34:17Z","timestamp":1629146057000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.89B8.19529"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,8]]},"references-count":30,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2007,8]]}},"alternative-id":["10.1302\/0301-620X.89B8.19529"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.89b8.19529","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,8]]}}}