{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T16:21:31Z","timestamp":1781454091353,"version":"3.54.1"},"reference-count":40,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"2","license":[{"start":{"date-parts":[[2008,2,1]],"date-time":"2008-02-01T00:00:00Z","timestamp":1201824000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2008,2]]},"abstract":"<jats:p>Ultra-high-molecular-weight polyethylene sterilised in the absence of air and highly cross-linked polyethylene have been used to avoid osteolysis and loosening in total hip replacement. Our prospective randomised study has assessed the results using two different polyethylenes associated with the same prosthetic design. We assessed 45 Allofit acetabular components with a Sulene-polyethylene liner of conventional polyethylene gamma sterilised with nitrogen and 45 Allofit acetabular components with a Durasul-polyethylene liner sterilised in ethylene oxide, both matched with an Alloclassic stem with a 28 mm modular femoral head. The prostheses were implanted between May 1999 and December 2001. The mean follow-up was for 66.3 months (60 to 92). The linear penetration of the femoral head was estimated at 6 weeks, at 6 and 12 months and annually thereafter from standardised digitised radiographs using image-analysis software.<\/jats:p><jats:p>There was no loosening of any prosthetic component. There were no radiolucent lines or osteolysis. The mean rate of penetration calculated from regression analysis during the first five years was 38 \u03bcm\/year (sd 2) for the Sulene group and 6 \u03bcm\/year (sd 1) for the Durasul group (p = 0.00002). The rate of penetration of the Durasul group was 15.7% of that of the Sulene group.<\/jats:p>","DOI":"10.1302\/0301-620x.90b2.19887","type":"journal-article","created":{"date-parts":[[2008,2,6]],"date-time":"2008-02-06T10:52:53Z","timestamp":1202295173000},"page":"149-153","source":"Crossref","is-referenced-by-count":60,"title":["New polyethylenes in total hip replacement"],"prefix":"10.1302","volume":"90-B","author":[{"given":"E.","family":"Garc\u00eda-Rey","sequence":"first","affiliation":[{"name":"Orthopaedics Department, Hospital Universitario La Paz, PO Castellana 261, 28046 Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Garc\u00eda-Cimbrelo","sequence":"additional","affiliation":[{"name":"Orthopaedics Department, Hospital Universitario La Paz, PO Castellana 261, 28046 Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Cruz-Pardos","sequence":"additional","affiliation":[{"name":"Orthopaedics Department, Hospital Universitario La Paz, PO Castellana 261, 28046 Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Ortega-Chamarro","sequence":"additional","affiliation":[{"name":"Orthopaedics Department, Hospital Universitario La Paz, PO Castellana 261, 28046 Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200112000-00007"},{"key":"R2","doi-asserted-by":"crossref","unstructured":"McKellop H, Shen FW, Lu B, Campbell P, Salovey R.Effect of sterilisation method and other modifications on the wear resistence of acetabular cups made of ultra-high molecular weight polyethylene: a hip simulator study. J Bone Joint Surg [Am] 2000;82-A:1708\u201325.","DOI":"10.2106\/00004623-200012000-00004"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2001.20540"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Rieker CB, Konrad R, Sch\u00f6n R, Schneider W, Abt NA.In vivo and in vitro surface changes in a highly cross-linked polyethylene. J Arthoplasty 2003;18(Suppl 1):48\u201354.","DOI":"10.1016\/S0883-5403(03)00303-6"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Greenwald AS, Bauer TW, Ries MD.Committee on hip and knee arthritis: new polys for old: contribution or caveat? J Bone Joint Surg [Am] 2001;83-A (Suppl 2):27\u201331.","DOI":"10.2106\/00004623-200100021-00007"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000073343.50837.03"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1177\/112070000201200211"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2003.08.003"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100170306"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B9.16265"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Digas G, K\u00e4rrholm J, Thanner J, Malchau H, Herberts P.Highly cross-linked polyethylene in cemented THA: randomised study of 61 hips. Clin Orthop 2003;417:126\u201338.","DOI":"10.1097\/01.blo.0000096802.78689.45"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2005.03.033"},{"key":"R13","doi-asserted-by":"crossref","unstructured":"Dorr LD, Wan Z, Shahrdar C, et al.Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. J Bone Joint Surg [Am] 2005;87-A:1816\u201321.","DOI":"10.2106\/00004623-200508000-00022"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2006.05.002"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1080\/17453670610012890"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2006.01.006"},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(97)90021-8"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1016\/8756-3282(93)90146-2"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-195436030-00001"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Johnston RC, Fitzgerald RH Jr, Harris WH, et al.Clinical and radiographic evaluation of total hip arthroplasty: a standard system of terminology for reporting results. J Bone Joint Surg [Am] 1990;72-A:161\u20138.","DOI":"10.2106\/00004623-199072020-00002"},{"key":"R21","doi-asserted-by":"crossref","unstructured":"DeLee JG, Charnley J.Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976;121:20\u201332.","DOI":"10.1097\/00003086-197611000-00003"},{"key":"R22","doi-asserted-by":"crossref","unstructured":"Moore MS, McAuley JP, Young AM, Engh CA Sr.Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop 2006;444:176\u201383.","DOI":"10.1097\/01.blo.0000201149.14078.50"},{"key":"R23","doi-asserted-by":"crossref","unstructured":"Dorr LD, Wan Z.Ten years of experience with porous acetabular components for revision surgery. Clin Orthop 1995;319:191\u2013200.","DOI":"10.1097\/00003086-199510000-00020"},{"key":"R24","doi-asserted-by":"crossref","unstructured":"Martell JM, Berdia S.Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg [Am] 1997;79-A:1635\u201341.","DOI":"10.2106\/00004623-199711000-00004"},{"key":"R25","doi-asserted-by":"crossref","unstructured":"Sychterz CJ, Engh CA Jr, Shah N, Engh CA Sr.Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time. J Bone Joint Surg [Am] 1997;79-A:1040\u20136.","DOI":"10.2106\/00004623-199707000-00010"},{"key":"R26","doi-asserted-by":"crossref","unstructured":"Sychterz CJ, Engh CA Jr, Yang A, Engh CA Sr.Analysis of temporal wear pattern of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in. J Bone Joint Surg [Am] 1999;81-A:821\u201330.","DOI":"10.2106\/00004623-199906000-00009"},{"key":"R27","doi-asserted-by":"crossref","unstructured":"Wan Z, Boutary M, Dorr LD.Precision and limitation of measuring two-dimensional wear on clinical radiographs. Clin Orthop 2006;449:267\u201374.","DOI":"10.1097\/01.blo.0000218758.35181.93"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"Callaghan JJ, Dysart SH, Savory CG.The uncemented porous-coated anatomic total hip prosthesis: two years of a prospective consecutive series. J Bone Joint Surg [Am] 1988;70-A:337\u201346.","DOI":"10.2106\/00004623-198870030-00004"},{"key":"R29","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC.\u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;171:17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"R30","doi-asserted-by":"crossref","unstructured":"Goetz DD, Smith JJ, Harris WH.The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements. J Bone Joint Surg [Am] 1994;76-A:1121\u20139.","DOI":"10.2106\/00004623-199408000-00002"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.69B1.3818732"},{"key":"R32","doi-asserted-by":"crossref","unstructured":"Engh CA, Glassman AH, Suthers KE.The case for porous-coated hip implants: the femoral side. Clin Orthop 1990;261:63\u201381.","DOI":"10.1097\/00003086-199012000-00009"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200301000-00017"},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B6.15335"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200212000-00010"},{"key":"R36","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B1.1732272"},{"key":"R37","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2001.23921"},{"key":"R38","doi-asserted-by":"publisher","DOI":"10.3109\/17453679909011255"},{"key":"R39","doi-asserted-by":"crossref","unstructured":"Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M.Total hip arthroplasty with use of the cementless Zweym\u00fcller Alloclassic system: a ten to thirteen-year follow-up study. J Bone Joint Surg [Am] 2003;85-A:296\u2013303.","DOI":"10.2106\/00004623-200302000-00017"},{"key":"R40","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200105000-00019"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.90B2.19887","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.90B2.19887","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.90B2.19887","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,16]],"date-time":"2023-05-16T08:00:50Z","timestamp":1684224050000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.90B2.19887"}},"subtitle":["A PROSPECTIVE, COMPARATIVE CLINICAL STUDY OF TWO TYPES OF LINER"],"short-title":[],"issued":{"date-parts":[[2008,2]]},"references-count":40,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2008,2]]}},"alternative-id":["10.1302\/0301-620X.90B2.19887"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.90b2.19887","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,2]]}}}