{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,21]],"date-time":"2026-05-21T02:19:59Z","timestamp":1779329999096,"version":"3.51.4"},"reference-count":11,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"4","license":[{"start":{"date-parts":[[2008,4,1]],"date-time":"2008-04-01T00:00:00Z","timestamp":1207008000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2008,4]]},"abstract":"<jats:p> We describe a case of symptomatic focal femoral osteolysis around a screw hole distal to the hydroxyapatite-coated portion of a cannulated femoral component in a revision hip replacement. No locking screw had been inserted into this, the most proximal of the three distal holes for locking screws. The presence of polyethylene wear debris in the tissue excised from the lesion suggested that it had passed through the cannulated portion of the stem and out of the proximal unfilled distal locking hole, initiating an osteolytic reaction in an otherwise well-fixed stem. This case highlights an important design characteristic of such cannulated, uncemented femoral components. We recommend that the proximal aperture of these cannulated stems be occluded at implantation. <\/jats:p>","DOI":"10.1302\/0301-620x.90b4.20168","type":"journal-article","created":{"date-parts":[[2008,3,31]],"date-time":"2008-03-31T21:23:15Z","timestamp":1206998595000},"page":"500-501","source":"Crossref","is-referenced-by-count":2,"title":["Focal femoral osteolysis after revision hip replacement with a cannulated, hydroxyapatite-coated long-stemmed femoral component"],"prefix":"10.1302","volume":"90-B","author":[{"given":"D. M.","family":"Rose","sequence":"first","affiliation":[{"name":"St Peter\u2019s Hospital, Guildford Road, Chertsey, Surrey KT16 0PZ, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Guryel","sequence":"additional","affiliation":[{"name":"St George\u2019s Hospital, Blackshaw Road, Tooting, London SW17 0QT, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K. J.","family":"Acton","sequence":"additional","affiliation":[{"name":"Royal Surrey County Hospital, Egerton Road, Guildford, Surrey GU2 7XX, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. W.","family":"Clark","sequence":"additional","affiliation":[{"name":"Worthing and Southlands Hospitals NHS Trust, Lyndhurst Road, Worthing, West Sussex BN11 2DH, UK."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.77B4.7615595"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.82B3.0820378"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.86B8.14928"},{"key":"R4","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B8.16053"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B7.17046"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B1.19731"},{"key":"R7","unstructured":"Duncan CP, Masri BA. Fractures of the femur after hip replacement. Instr Course Lect 1995;44:293\u2013304."},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.83B3.0830441"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-006-0168-8"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.86B1.13402"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.148.3.6878678"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.90B4.20168","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.90B4.20168","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.90B4.20168","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T18:38:12Z","timestamp":1629139092000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.90B4.20168"}},"subtitle":["A NEW ROUTE FOR PARTICULATE WEAR DEBRIS"],"short-title":[],"issued":{"date-parts":[[2008,4]]},"references-count":11,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2008,4]]}},"alternative-id":["10.1302\/0301-620X.90B4.20168"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.90b4.20168","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,4]]}}}