{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T03:50:30Z","timestamp":1783482630116,"version":"3.55.0"},"reference-count":20,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"12","license":[{"start":{"date-parts":[[2009,12,1]],"date-time":"2009-12-01T00:00:00Z","timestamp":1259625600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2009,12]]},"abstract":"<jats:p> We report the minimum five-year follow-up of 352 primary total hip replacements using the uncemented hydroxyapatite-coated ANCA-Fit femoral component with a modular neck and head. The series comprised 319 patients (212 men, 107 women) with a mean age at operation of 64.4 years (28 to 97). The principal diagnosis was osteoarthritis. A total of 18 patients (21 hips) died before their follow-up at five years, nine patients (11 hips) were lost to follow-up, and four (four hips) declined further follow-up. Patient-reported outcomes have been recorded for 288 patients (316 hips). <\/jats:p><jats:p> Their mean Oxford Hip Score improved significantly from 41 points (16 to 57) pre-operatively to 20 points (12 to 44) at five-year follow-up. Radiological assessment showed good bony stability in 98% of implants. There were two cases of aseptic loosening of the femoral component. There were no clinical or radiological complications related to modularity. In our series we did not see the high rate of intra-operative fracture previously reported for this implant. <\/jats:p><jats:p> This medium-term follow-up study demonstrates that the clinical outcome of the ANCA-Fit femoral component is, to date, comparable with that of other metaphyseal loading femoral components. <\/jats:p>","DOI":"10.1302\/0301-620x.91b12.22638","type":"journal-article","created":{"date-parts":[[2009,11,30]],"date-time":"2009-11-30T22:40:02Z","timestamp":1259620802000},"page":"1561-1565","source":"Crossref","is-referenced-by-count":18,"title":["Mid-term results of the modular ANCA-Fit femoral component in total hip replacement"],"prefix":"10.1302","volume":"91-B","author":[{"given":"C. M.","family":"Blakey","sequence":"first","affiliation":[{"name":"Research and Education South West London Elective Orthopaedic Centre, Epsom, Surrey KT18 7EG, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V. K.","family":"Eswaramoorthy","sequence":"additional","affiliation":[{"name":"Research and Education South West London Elective Orthopaedic Centre, Epsom, Surrey KT18 7EG, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. C.","family":"Hamilton","sequence":"additional","affiliation":[{"name":"3rd Floor, Plastic Surgery Department Lambeth Wing, St. Thomas\u2019 Hospital, Westminster Bridge Road, London SE1 7EH, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. C.","family":"Biant","sequence":"additional","affiliation":[{"name":"Royal Infirmary of Edinburgh, Little France Crescent, Old Dalkeith Road, Edinburgh EH16 4SA, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. E.","family":"Field","sequence":"additional","affiliation":[{"name":"Research and Education South West London Elective Orthopaedic Centre, Epsom, Surrey KT18 7EG, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"crossref","unstructured":"Bobyn JD, Tanzer M, Krygier JJ, Dujovne AR, Brooks CE. Concerns with modularity in total hip arthroplasty. Clin Orthop 1994;298:27\u201336.","DOI":"10.1097\/00003086-199401000-00006"},{"key":"R2","doi-asserted-by":"crossref","unstructured":"McCarthy JC, Bono JV, O\u2019Donnell PJ. Custom and modular components in primary total hip replacement. Clin Orthop 1997;344:162\u201371.","DOI":"10.1097\/00003086-199711000-00017"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.78B2.0780185"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop 1990;257:107\u201328.","DOI":"10.1097\/00003086-199008000-00022"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC. \u2018Modes of failure\u2019 of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141:17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197355080-00006"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.67B5.4055873"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.77B6.7593096"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200107000-00019"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Gilbert JL, Buckley CA, Jacobs JJ, Bertin KC, Zernich MR. Intergranular corrosion fatigue failure of cobalt-alloy femoral stems: a failure analysis of two implants. J Bone Joint Surg [Am] 1994;76-A:110\u201315.","DOI":"10.2106\/00004623-199401000-00014"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Pellicci PM, Haas SB. Disassembly of a modular femoral component during closed reduction of the dislocated femoral component: a case report. J Bone Joint Surg [Am] 1990;72-A:619\u201323.","DOI":"10.2106\/00004623-199072040-00020"},{"key":"R12","doi-asserted-by":"crossref","unstructured":"Urban RM, Jacobs JJ, Gilbert JL, Galante JO. Migration of corrosion products from modular hip prostheses: particle microanalysis and histopathological findings. J Bone Joint Surg [Am] 1994;76-A:1345\u201359.","DOI":"10.2106\/00004623-199409000-00009"},{"key":"R13","doi-asserted-by":"crossref","unstructured":"Amstutz HC, Campbell P, Kossovsky N, Clark IC. Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthop 1992;276:7\u201318.","DOI":"10.1097\/00003086-199203000-00003"},{"key":"R14","unstructured":"Gill EK, Edge J. A randomized prospective trial to compare two designs of hydroxyapatite coated femoral stems for total hip replacement. Procs 8th EFORT Congress, 2007."},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1177\/112070000101100101"},{"key":"R16","doi-asserted-by":"crossref","unstructured":"Lettich T, Tierney MG, Parvizi J, Sharkey PF, Rothman RH. Primary total hip arthroplasty with an uncemented femoral component: two- to seven-year results. J Arthroplasty 2007;22:43\u20136.","DOI":"10.1016\/j.arth.2007.07.001"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"Mulliken BD, Bourne RB, Rorabeck CH, Nayak N. A tapered titanium femoral stem inserted without cement in total hip arthroplasty: radiographic evaluation and stability. J Bone Joint Surg [Am] 1996;78-A:1214\u201325.","DOI":"10.2106\/00004623-199608000-00012"},{"key":"R18","unstructured":"No authors listed. National Institute for Clinical Excellence (NICE): Technology Appraisal Guidance No. 2. Guidance on the selection of prosthesis for primary total hip replacement. http:\/\/www.nice.org.uk\/Guidance\/TA2 (date last accessed 19 March 2009)."},{"key":"R19","unstructured":"No authors listed. NHS Supply Chain: ODEP Database. http:\/\/www.supply-chain.nhs.uk\/portal\/page\/portal\/Products%20new\/Orthopaedics\/ODEP%20(Ortho-paedic%20Data%20Evaluation%20Panel) (date last accessed 19 March 2009)."},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B5.15390"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.91B12.22638","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.91B12.22638","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.91B12.22638","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T18:21:29Z","timestamp":1629138089000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.91B12.22638"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,12]]},"references-count":20,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["10.1302\/0301-620X.91B12.22638"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.91b12.22638","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,12]]}}}