{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T23:27:36Z","timestamp":1781220456133,"version":"3.54.1"},"reference-count":53,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"2","license":[{"start":{"date-parts":[[2009,2,1]],"date-time":"2009-02-01T00:00:00Z","timestamp":1233446400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2009,2]]},"abstract":"<jats:p> The aim of this study was to determine the functional outcome and rate of re-tears following mini-open repair of symptomatic large and massive tears of the rotator cuff using a two-row technique. <\/jats:p><jats:p> The 24 patients included in the study were assessed prospectively before and at a mean of 27 months (18 to 53) after surgery using the Constant and the Oxford Shoulder scores. Ultrasound examination was carried out at follow-up to determine the integrity of the repair. Patient satisfaction was assessed using a simple questionnaire. <\/jats:p><jats:p> The mean Constant score improved significantly from 36 before to 68 after operation (p &lt; 0.0001) and the mean Oxford Shoulder score from 39 to 20 (p &lt; 0.0001). Four of the 24 patients (17%) had a re-tear diagnosed by ultrasound. A total of 21 patients (87.5%) were satisfied with the outcome of their surgery. The repair remained intact in 20 patients (83%). However, the small number of re-tears (four patients) in the study did not allow sufficient analysis to show a difference in outcome in relation to the integrity of the repair. <\/jats:p>","DOI":"10.1302\/0301-620x.91b2.21286","type":"journal-article","created":{"date-parts":[[2009,2,3]],"date-time":"2009-02-03T14:02:41Z","timestamp":1233669761000},"page":"201-205","source":"Crossref","is-referenced-by-count":49,"title":["Large and massive tears of the rotator cuff"],"prefix":"10.1302","volume":"91-B","author":[{"given":"B. C.","family":"Hanusch","sequence":"first","affiliation":[{"name":"Orthopaedic Research Office, Academic Centre"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Goodchild","sequence":"additional","affiliation":[{"name":"Physiotherapist, Department of Rehabilitation"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Finn","sequence":"additional","affiliation":[{"name":"School of Health & Social Care University of Teesside, Middlesbrough TS1 3BA, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Rangan","sequence":"additional","affiliation":[{"name":"Department of Trauma & Orthopaedics James Cook University Hospital, Marton Road, Middlesbrough TS4 3BW, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20070601-05"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1016\/S1058-2746(98)90050-7"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(03)00169-5"},{"key":"R4","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B4.16407"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1097\/00042752-200205000-00002"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K. The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg [Am] 2004;86-A:219\u201324.","DOI":"10.2106\/00004623-200402000-00002"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.12.028"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B10.19989"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.01.019"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Rokito AS, Cuomo F, Gallagher MA, Zuckerman JD. Long-term functional outcome of repair of large and massive chronic tears of the rotator cuff. J Bone Joint Surg [Am] 1999;81-A:991\u20137.","DOI":"10.2106\/00004623-199907000-00012"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1016\/1058-2746(92)90089-L"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(96)90219-4"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2004.02.016"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1016\/S1058-2746(99)90050-2"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2006.12.012"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2003.11.013"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"Tauro JC. Arthroscopic repair of large rotator cuff tears using the interval slide technique. Arthroscopy 2004;20:13\u201321.","DOI":"10.1016\/j.arthro.2003.10.013"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop 1987;214:160\u20134.","DOI":"10.1097\/00003086-198701000-00023"},{"key":"R19","doi-asserted-by":"crossref","unstructured":"Dawson J, Fitzpatrick R, Carr A. Questionnaire on the perceptions of patients about shoulder surgery. J Bone Joint Surg [Br] 1996;78:593\u2013600.","DOI":"10.1302\/0301-620X.78B4.0780593"},{"key":"R20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2004.07.003"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(88)80038-0"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(87)80061-0"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(91)90071-5"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1016\/S0030-5898(05)70269-8"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200101000-00010"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1177\/0363546505275130"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1177\/03635465000280030401"},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(00)90026-4"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.01.011"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-2-24"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2005.09.008"},{"key":"R32","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2003.50036"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2004.11.006"},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2005.02.002"},{"key":"R35","doi-asserted-by":"crossref","unstructured":"Galatz LM, Griggs S, Cameron BD, Iannotti JP. Prospective longitudinal analysis of postoperative shoulder function: a ten-year follow-up study of full-thickness rotator cuff tears. J Bone Joint Surg [Am] 2001;83-A:1052\u20136.","DOI":"10.2106\/00004623-200107000-00011"},{"key":"R36","doi-asserted-by":"crossref","unstructured":"Gerber C, Fuchs B, Hodler J. The results of repair of massive tears of the rotator cuff. J Bone Joint Surg [Am] 2000;82-A:505\u201315.","DOI":"10.2106\/00004623-200004000-00006"},{"key":"R37","doi-asserted-by":"publisher","DOI":"10.1007\/s00113-003-0662-1"},{"key":"R38","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.184.5.01841456"},{"key":"R39","doi-asserted-by":"crossref","unstructured":"Prickett WD, Teefey SA, Galatz LM, et al. Accuracy of ultrasound imaging of the rotator cuff in shoulders that are painful postoperatively. J Bone Joint Surg [Am] 2003;85-A:1084\u20139.","DOI":"10.2106\/00004623-200306000-00016"},{"key":"R40","doi-asserted-by":"crossref","unstructured":"Gaenslen ES, Satterlee CC, Hinson GW. Magnetic resonance imaging for evaluation of failed repairs of the rotator cuff. J Bone Joint Surg [Am] 1996;78-A:1391\u20136.","DOI":"10.2106\/00004623-199609000-00015"},{"key":"R41","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.181.5.1811227"},{"key":"R42","doi-asserted-by":"crossref","unstructured":"Schneeberger AG, von Roll A, Kalberer F, Jacob HA, Gerber C. Mechanical strength of arthroscopic rotator cuff repair techniques: an in vivo study. J Bone Joint Surg [Am] 2002;84-A:2152\u201360.","DOI":"10.2106\/00004623-200212000-00005"},{"key":"R43","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(97)90006-2"},{"key":"R44","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(97)90034-7"},{"key":"R45","doi-asserted-by":"publisher","DOI":"10.1016\/0749-8063(95)90084-5"},{"key":"R46","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-007-0382-0"},{"key":"R47","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2006.03.004"},{"key":"R48","doi-asserted-by":"publisher","DOI":"10.1177\/0363546505281238"},{"key":"R49","doi-asserted-by":"publisher","DOI":"10.1177\/03635465030310040301"},{"key":"R50","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B10.20862"},{"key":"R51","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.76B3.8175836"},{"key":"R52","doi-asserted-by":"publisher","DOI":"10.1016\/S0749-8063(03)00395-5"},{"key":"R53","doi-asserted-by":"publisher","DOI":"10.1053\/jars.2002.32589"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.91B2.21286","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.91B2.21286","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.91B2.21286","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T18:23:47Z","timestamp":1629138227000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.91B2.21286"}},"subtitle":["FUNCTIONAL OUTCOME AND INTEGRITY OF THE REPAIR AFTER A MINI-OPEN PROCEDURE"],"short-title":[],"issued":{"date-parts":[[2009,2]]},"references-count":53,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2009,2]]}},"alternative-id":["10.1302\/0301-620X.91B2.21286"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.91b2.21286","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,2]]}}}