{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,10]],"date-time":"2026-01-10T01:23:41Z","timestamp":1768008221560,"version":"3.49.0"},"reference-count":40,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"12","license":[{"start":{"date-parts":[[2010,12,1]],"date-time":"2010-12-01T00:00:00Z","timestamp":1291161600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2010,12]]},"abstract":"<jats:p> We reviewed 123 second-generation uncemented total hip replacements performed on 115 patients by a single surgeon between 1993 and 1994. The acetabular component used in all cases was a fully porous-coated threaded hemispheric titanium shell (T-Tap ST) with a calcium ion stearate-free, isostatically compression-moulded polyethylene liner. The titanium femoral component used was a Taperloc with a reduced distal stem. No patient was lost to follow-up. Complete clinical and radiological follow-up was obtained for all 123 hips at a mean of 14 years (12 to 16). One femoral component was revised after a fracture, and three acetabular components for aseptic loosening. No additional femoral or acetabular components were judged loose by radiological criteria. Mild proximal femoral osteolysis was identified in two hips and minor acetabular osteolysis was present in four. The mean rate of penetration of the femoral head was 0.036 mm\/year (0.000 to 0.227). <\/jats:p><jats:p> These findings suggest that refinements in component design may be associated with excellent long-term fixation in cementless primary total hip replacement. <\/jats:p>","DOI":"10.1302\/0301-620x.92b12.24582","type":"journal-article","created":{"date-parts":[[2010,12,1]],"date-time":"2010-12-01T00:50:10Z","timestamp":1291164610000},"page":"1636-1641","source":"Crossref","is-referenced-by-count":38,"title":["Cementless total hip replacement using second-generation components"],"prefix":"10.1302","volume":"92-B","author":[{"given":"J. R.","family":"McLaughlin","sequence":"first","affiliation":[{"name":"Mercy Medical Center, 2700 W Ninth Avenue, Suite 125, Oshkosh, Wisconsin 54904, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K. R.","family":"Lee","sequence":"additional","affiliation":[{"name":"Gundersen Lutheran Medical Center, 1900 South Avenue, La Crosse, Wisconsin 54601, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198264070-00017"},{"key":"R2","doi-asserted-by":"crossref","unstructured":"Harris WH, McGann WA. Loosening of the femoral component after use of the medullary-plug cementing technique: follow-up note with a minimum five-year follow-up. J Bone Joint Surg [Am] 1986;68-A:1064\u20136.","DOI":"10.2106\/00004623-198668070-00014"},{"key":"R3","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.72B5.2211749"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Buckwalter AE, Callaghan JJ, Liu SS, et al. Results of Charnley total hip arthroplasty with use of improved femoral cementing techniques: a concise follow-up, at a minimum of twenty-five years, of a previous report. J Bone Joint Surg [Am] 2006;88-A:1481\u20135.","DOI":"10.2106\/00004623-200607000-00008"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Goetz D, Smith EJ, Harris WH. The prevalence of femoral osteolysis associated with components inserted with or without cement in total hip replacements: a retrospective matched-pair series. J Bone Joint Surg [Am] 1994;76-A:1121\u20139.","DOI":"10.2106\/00004623-199408000-00002"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Haddad RJ Jr, Skalley TC, Cook SD, et al. Clinical and roentgenographic evaluation of noncemented porous-coated anatomic medullary locking (AML) and porous-coated anatomic (PCA) total hip arthroplasties. Clin Orthop 1990;258:176\u201382.","DOI":"10.1097\/00003086-199009000-00022"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B5.15554"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(99)90003-7"},{"key":"R9","doi-asserted-by":"crossref","unstructured":"McLaughlin JR, Lee KR. Total hip arthroplasty with an uncemented tapered femoral component. J Bone Joint Surg [Am] 2008;90-A:1290\u20136.","DOI":"10.2106\/JBJS.G.00771"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Belmont PJ Jr, Powers CC, Beykirch SE, et al. Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years: a concise follow-up of previous reports. J Bone Joint Surg [Br] 2008;90-A:1524\u201330.","DOI":"10.2106\/JBJS.G.01142"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B10.20274"},{"key":"R12","doi-asserted-by":"crossref","unstructured":"Gr\u00fcbl A, Chiari C, Giurea A, et al. Cementless total hip arthroplasty with the rectangular titanium Zweymuller stem: a concise follow-up, at a minimum of fifteen years, of a previous report. J Bone Joint Surg [Am] 2006;88-A:2210\u201315.","DOI":"10.2106\/00004623-200610000-00013"},{"key":"R13","doi-asserted-by":"crossref","unstructured":"Della Valle CJ, Berger RA, Shott S, et al. Primary total hip arthroplasty with a porous-coated acetabular component: a concise follow-up of a previous report. J Bone Joint Surg [Am] 2004;86-A:1217\u201322.","DOI":"10.2106\/00004623-200406000-00014"},{"key":"R14","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC. \u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141:17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.69B1.3818732"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B6.1447240"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976;121:20\u201332.","DOI":"10.1097\/00003086-197611000-00003"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(89)80020-8"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199072040-00008"},{"key":"R20","unstructured":"No authors listed. ROentgen MOnographic ANalysis (Roman). The Robert Jones and Agnes Hunt Orthopaedic Hospital, Oswestry, United Kingdom. http:\/\/www.keele.ac.uk\/depts\/rjah\/index.htm (date last accessed 3 August 2010)."},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-196951040-00012"},{"key":"R22","doi-asserted-by":"crossref","unstructured":"Johnston RC, Fitzgerald RH Jr, Harris WH, et al. Clinical and radiographic evaluation of total hip replacement: a standard of terminology for reporting results. J Bone Joint Surg [Am] 1990;72-A:161\u20138.","DOI":"10.2106\/00004623-199072020-00002"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1080\/01621459.1958.10501452"},{"key":"R24","unstructured":"Fisher LD, Van Belle G. Biostatistics: a methodology for the health sciences. Chichester: Wiley and Sons Inc. 1933."},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2005.08.011"},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B5.20116"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.91B3.20947"},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.74B3.1587883"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4636(1999)48:3<374::AID-JBM23>3.0.CO;2-O"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B6.15335"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200301000-00017"},{"key":"R32","doi-asserted-by":"crossref","unstructured":"Berger RA, Jacobs JJ, Quigley LR, Rosenberg AG, Galante JO. Primary cementless acetabular reconstruction in patients younger than 50 years old: 7- to 11-year results. Clin Orthop 1997;344:216\u201326.","DOI":"10.1097\/00003086-199711000-00022"},{"key":"R33","doi-asserted-by":"crossref","unstructured":"Heekin RD, Callaghan JJ, Hopkinson WJ, Savory CG, Xenos JS. The porous-coated anatomic total hip prosthesis, inserted without cement: results after five to seven years in a prospective study. J Bone Joint Surg [Am] 1993;75-A:77\u201391.","DOI":"10.2106\/00004623-199301000-00011"},{"key":"R34","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(05)80201-3"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.75B1.8421036"},{"key":"R36","doi-asserted-by":"publisher","DOI":"10.1016\/0883-5403(94)90078-7"},{"key":"R37","doi-asserted-by":"crossref","unstructured":"McCalden RW, MacDonald SJ, Rorabeck CH, et al. Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg [Am] 2009;91-A:773\u201382.","DOI":"10.2106\/JBJS.H.00244"},{"key":"R38","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B5.20545"},{"key":"R39","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.04.016"},{"key":"R40","unstructured":"Bankston AB, Keating EM, Ranawat C, Faris PM, Ritter MA. Comparison of polyethylene wear in machined versus molded polyethylene. Clin Orthop 1995;317:37\u201343."}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.92B12.24582","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.92B12.24582","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.92B12.24582","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T18:57:32Z","timestamp":1629140252000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.92B12.24582"}},"subtitle":["A 12- TO 16-YEAR FOLLOW-UP"],"short-title":[],"issued":{"date-parts":[[2010,12]]},"references-count":40,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2010,12]]}},"alternative-id":["10.1302\/0301-620X.92B12.24582"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.92b12.24582","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,12]]}}}