{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T03:22:47Z","timestamp":1783480967691,"version":"3.55.0"},"reference-count":39,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"2","license":[{"start":{"date-parts":[[2010,2,1]],"date-time":"2010-02-01T00:00:00Z","timestamp":1264982400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2010,2]]},"abstract":"<jats:p> The Norwegian Arthroplasty Register has shown that several designs of uncemented femoral stems give good or excellent survivorship. The overall findings for uncemented total hip replacement however, have been disappointing because of poor results with the use of metal-backed acetabular components. In this study, we exclusively investigated the medium-to long-term performance of primary uncemented metal-backed acetabular components. <\/jats:p><jats:p> A total of 9113 primary uncemented acetabular components were implanted in 7937 patients between 1987 and 2007. These were included in a prospective, population-based observational study. All the implants were modular and metal-backed with ultra-high-molecular-weight polyethylene liners. The femoral heads were made of stainless steel, cobalt-chrome (CoCr) alloy or alumina ceramic. In all, seven different designs of acetabular component were evaluated by the Kaplan-Meier survivorship method and Cox regression analysis. <\/jats:p><jats:p> Most acetabular components performed well up to seven years. When the endpoint was revision of the acetabular component because of aseptic loosening, the survival ranged between 87% and 100% at ten years. However, when the endpoint was revision for any reason, the survival estimates were 81% to 92% for the same implants at ten years. Aseptic loosening, wear, osteolysis and dislocation were the main reasons for the relatively poor overall performance of the acetabular components. Prostheses with alumina heads performed slightly better than those with stainless steel or CoCr alloy in subgroups. <\/jats:p><jats:p> Whereas most acetabular components performed well at seven years, the survivorship declined with longer follow-up. Fixation was generally good. None of the metal-backed uncemented acetabular components with ultra-high-molecular-weight polyethylene liners in our study had satisfactory long-term results because of high rates of wear, osteolysis, aseptic loosening and dislocation. <\/jats:p>","DOI":"10.1302\/0301-620x.92b2.22179","type":"journal-article","created":{"date-parts":[[2010,2,4]],"date-time":"2010-02-04T03:05:19Z","timestamp":1265252719000},"page":"196-201","source":"Crossref","is-referenced-by-count":42,"title":["Metal-backed acetabular components with conventional polyethylene"],"prefix":"10.1302","volume":"92-B","author":[{"given":"G.","family":"Hallan","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Haukeland University Hospital, Jonas Liesvei 65, 5021 Bergen, Norway."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.","family":"Dybvik","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Haukeland University Hospital, Jonas Liesvei 65, 5021 Bergen, Norway."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"O.","family":"Furnes","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Haukeland University Hospital, Jonas Liesvei 65, 5021 Bergen, Norway."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. I.","family":"Havelin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Haukeland University Hospital, Jonas Liesvei 65, 5021 Bergen, Norway."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1080\/000164700317393321"},{"key":"R2","unstructured":"Furnes O, Espehaug, Lie SA, et al. Prospective studies of hip and knee prostheses: The Norwegian Arthroplasty Register 1987\u20132004. Scientific Exhibition AAOS, Washington DC, 2005."},{"key":"R3","unstructured":"Herberts P, Karrholm J, Garellick G. Annual report 2004. The Swedish national hip arthroplasty register. 2005. Department of Orthopaedic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden. https:\/\/www.jru.orthop.gu.se (date last accessed 4 December 2009)."},{"key":"R4","unstructured":"Graves S, Davidson D, Ingerson L. Annual Report 2005, Australian Orthopaedic Association National Joint Replacement Registry, 2005. https:\/\/www.aoa.org.au (date last accessed 4 December 2009)."},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B12.18969"},{"key":"R6","doi-asserted-by":"crossref","unstructured":"Grubl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F. Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg [Am] 2002;84-A:425\u201331.","DOI":"10.2106\/00004623-200203000-00014"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2003.10.003"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B6.0840839"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.3109\/17453679509002301"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B5.0840641"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Berger RA, Quigley LR, Jacobs JJ, et al. The fate of stable cemented acetabular components retained during revision of a femoral component of a total hip arthroplasty. J Bone Joint Surg [Am] 1999;81-A:1682\u201391.","DOI":"10.2106\/00004623-199912000-00005"},{"key":"R12","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.87B6.15335"},{"key":"R13","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.01.005"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-006-0075-1"},{"key":"R15","doi-asserted-by":"crossref","unstructured":"Bojescul JA, Xenos JS, Callaghan JJ, Savory CG. Results of porous-coated anatomic total hip arthroplasty without cement at fifteen years: a concise follow-up of a previous report. J Bone Joint Surg [Am] 2003;85-A:1079\u201383.","DOI":"10.2106\/00004623-200306000-00015"},{"key":"R16","doi-asserted-by":"crossref","unstructured":"D\u2019Antonio JA, Capello WN, Manley MT, Feinberg J. Hydroxyapatite coated implants: total hip arthroplasty in the young patient and patients with avascular necrosis. Clin Orthop 1997;344:124\u201338.","DOI":"10.1097\/00003086-199711000-00014"},{"key":"R17","doi-asserted-by":"crossref","unstructured":"Manley MT, Capello WN, D\u2019Antonio JA, Edidin AA, Geesink RG. Fixation of acetabular cups without cement in total hip arthroplasty: a comparison of three different implant surfaces at a minimum duration of follow-up of five years. J Bone Joint Surg [Am] 1998;80-A:1175\u201385.","DOI":"10.2106\/00004623-199808000-00011"},{"key":"R18","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.91B7.22013"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B11.20892"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Crowther JD, Lachiewicz PF. Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: results at nine to fourteen years. J Bone Joint Surg [Am] 2002;84-A:729\u201335.","DOI":"10.2106\/00004623-200205000-00005"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.11.006"},{"key":"R22","doi-asserted-by":"crossref","unstructured":"Engh CA, Hopper RH Jr, Engh CA Jr. Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty 2004;19:54\u201360.","DOI":"10.1016\/j.arth.2004.06.004"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1080\/17453670610045696"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1080\/01621459.1958.10501452"},{"key":"R25","doi-asserted-by":"publisher","DOI":"10.1016\/0197-2456(96)00075-X"},{"key":"R26","doi-asserted-by":"crossref","unstructured":"Cox D. Regression models and life tables. J Roy Statist Soc 1972;32:187\u2013220.","DOI":"10.1111\/j.2517-6161.1972.tb00899.x"},{"key":"R27","doi-asserted-by":"crossref","unstructured":"Bragdon CR, Kwon YM, Geller JA, et al. Minimum 6-year follow-up of highly cross-linked polyethylene in THA. Clin Orthop 2007;465:122\u20137.","DOI":"10.1097\/BLO.0b013e31815760b1"},{"key":"R28","doi-asserted-by":"crossref","unstructured":"McCalden RW, MacDonald SJ, Rorabeck CH, et al. Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg [Am] 2009;91-A:773\u201382.","DOI":"10.2106\/JBJS.H.00244"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2006.12.117"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B5.20545"},{"key":"R31","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B11.19543"},{"key":"R32","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B2.19887"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200800001-00017"},{"key":"R34","unstructured":"Nashed RS, Becker DA, Gustilo RB. Are cementless acetabular components the cause of excess wear and osteolysis in total hip arthroplasty? Clin Orthop 1995;317:19\u201328."},{"key":"R35","doi-asserted-by":"crossref","unstructured":"Sychterz CJ, Moon KH, Hashimoto Y, et al. Wear of polyethylene cups in total hip arthroplasty: a study of specimens retrieved post mortem. J Bone Joint Surg [Am] 1996;78-A:1193\u2013200.","DOI":"10.2106\/00004623-199608000-00009"},{"key":"R36","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)90011-0"},{"key":"R37","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(03)00266-3"},{"key":"R38","doi-asserted-by":"crossref","unstructured":"Griffin WL, Fehring TK, Mason JB, et al. Early morbidity of modular exchange for polyethylene wear and osteolysis. J Arthroplasty 2004;19(Suppl 2):61\u20136.","DOI":"10.1016\/j.arth.2004.06.014"},{"key":"R39","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B5.18623"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.92B2.22179","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.92B2.22179","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.92B2.22179","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T17:59:40Z","timestamp":1629136780000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.92B2.22179"}},"subtitle":["A REVIEW OF 9113 PRIMARY COMPONENTS WITH A FOLLOW-UP OF 20 YEARS"],"short-title":[],"issued":{"date-parts":[[2010,2]]},"references-count":39,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2010,2]]}},"alternative-id":["10.1302\/0301-620X.92B2.22179"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.92b2.22179","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,2]]}}}