{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T02:49:46Z","timestamp":1777603786826,"version":"3.51.4"},"reference-count":55,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"2","license":[{"start":{"date-parts":[[2010,2,1]],"date-time":"2010-02-01T00:00:00Z","timestamp":1264982400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2010,2]]},"abstract":"<jats:p> Implantation of a large-diameter femoral head prosthesis with a metal-on-metal bearing surface reduces the risk of dislocation, increases the range of movement, minimises the risk of impingement and, in theory, results in little wear. <\/jats:p><jats:p> Between February 2004 and March 2007 we implanted 100 consecutive total hip replacements with a metal-on-metal bearing and a large femoral head into 92 patients. There were 51 men and 41 women with a mean age of 50 years (18 to 70) at the time of surgery. <\/jats:p><jats:p> Outcome was assessed using the Western Ontario McMaster University osteoarthritis index and the Harris hip score as well as the Devane activity score. These all improved significantly (p &lt; 0.0001). At the last follow-up there were no cases of dislocation, no impingement, a good range of movement and no osteolysis, but seven revisions, two for infection and five for aseptic loosening. The probability of groin pain increased if the other acetabular component inclination exceeded 50\u00b0 (p = 0.0007). At 4.8 years of follow-up, the projected survival of the Durom acetabular component, with revision for any reason, was 92.4% (sd 2.8) (95% confidence interval 89.6 to 95.2). <\/jats:p><jats:p> The design of the component made it difficult both to orientate and seat, which when combined with a poor porous coating, produced unpredictable fixation and a low survival at five years. <\/jats:p>","DOI":"10.1302\/0301-620x.92b2.22653","type":"journal-article","created":{"date-parts":[[2010,2,4]],"date-time":"2010-02-04T03:05:19Z","timestamp":1265252719000},"page":"202-208","source":"Crossref","is-referenced-by-count":67,"title":["The Durom Large Diameter Head acetabular component"],"prefix":"10.1302","volume":"92-B","author":[{"given":"C.","family":"Berton","sequence":"first","affiliation":[{"name":"Service d\u2019Orthop\u00e9die C, H\u00f4pital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille Cedex, France."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Girard","sequence":"additional","affiliation":[{"name":"Service d\u2019Orthop\u00e9die C, H\u00f4pital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille Cedex, France."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Krantz","sequence":"additional","affiliation":[{"name":"Service d\u2019Orthop\u00e9die C, H\u00f4pital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille Cedex, France."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Migaud","sequence":"additional","affiliation":[{"name":"Service d\u2019Orthop\u00e9die C, H\u00f4pital Salengro, CHRU de Lille, Place de Verdun, 59037 Lille Cedex, France."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"crossref","unstructured":"Migaud H, Jobin A, Chantelot C, et al. Cementless metal-on-metal hip arthroplasty in patients less than 50 years of age: comparison with a matched control group using ceramic-on-polyethylene after a minimum 5-year follow-up. J Arthroplasty 2004;19(Suppl 3):23\u20138.","DOI":"10.1016\/S0883-5403(04)00490-5"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)90089-4"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Callaghan JJ, Forest EE, Olejniczak JP, Goetz DD, Johnston RC. Charnley total hip arthroplasty in patients less than fifty years old: a twenty to twenty-five-year follow-up note. J Bone Joint Surg [Am] 1998;80-A:704\u201314.","DOI":"10.2106\/00004623-199805000-00011"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"McKee GK, Chen SC. The statistics of the McKee-Farrar method of total hip replacement. Clin Orthop 1973;95:26\u201333.","DOI":"10.1097\/00003086-197309000-00004"},{"key":"R5","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199608000-00009"},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.68B4.3733823"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199608001-00003"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199608001-00004"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199608001-00013"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(99)90059-1"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(96)80085-4"},{"key":"R12","doi-asserted-by":"crossref","unstructured":"Tuke MA, Scott G, Roques A, Hu XQ, Taylor A. Design considerations and life prediction of metal-on-metal bearings: the effect of clearance. J Bone Joint Surg [Am] 2008;90-A(Suppl 3):134\u201341.","DOI":"10.2106\/JBJS.H.00610"},{"key":"R13","unstructured":"Ray A. 15 years survival of the Mac-Kee Farrar metal hip prosthesis: a propos of 58 cases and 4 explanted cups. Rev Chir Orthop Reparatrice Appar Mot 1996;82:85\u20139 (in French)."},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B9.20524"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B4.19648"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B10.20378"},{"key":"R17","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199608001-00007"},{"key":"R18","doi-asserted-by":"crossref","unstructured":"Cuckler JM, Moore KD, Lombardi AV Jr, McPherson E, Emerson R. Large versus small femoral heads in metal-on-metal total hip arthroplasty. J Arthroplasty 2004;19(Suppl 3):41\u20134.","DOI":"10.1016\/j.arth.2004.09.006"},{"key":"R19","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000150117.42360.f9"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Bartz RL, Noble PC, Kadakia NR, Tullos HS. The effect of femoral component head size on posterior dislocation of the artificial hip joint. J Bone Joint Surg [Am] 2000;82-A:1300\u20137.","DOI":"10.2106\/00004623-200009000-00010"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.07.008"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1016\/S0035-1040(07)90252-4"},{"key":"R23","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B10.20533"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(97)90021-8"},{"key":"R25","unstructured":"Merle d\u2019Aubign\u00e9 R. Numerical evaluation of hip function. Rev Chir Orthop Reparatrice Appar Mot 1970;56:481\u20136 (in French)."},{"key":"R26","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-196951040-00012"},{"key":"R27","unstructured":"Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirhematic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 1988;15:1833\u201340."},{"key":"R28","doi-asserted-by":"publisher","DOI":"10.1016\/j.rco.2007.09.002"},{"key":"R29","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.69B1.3818732"},{"key":"R30","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(89)80020-8"},{"key":"R31","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC. \u201cModes of failure\u201d of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141:17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"R32","doi-asserted-by":"crossref","unstructured":"DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976;121:20\u201332.","DOI":"10.1097\/00003086-197611000-00003"},{"key":"R33","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-197355080-00006"},{"key":"R34","doi-asserted-by":"crossref","unstructured":"Stuchin SA. Anatomic diameter femoral heads in total hip arthroplasty: a preliminary report. J Bone Joint Surg [Am] 2008;90-A(Suppl 3):52\u20136.","DOI":"10.2106\/JBJS.H.00690"},{"key":"R35","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000218742.61624.80"},{"key":"R36","doi-asserted-by":"crossref","unstructured":"Berry DJ, von Knoch M, Schleck CD, Harmsen WS. Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg [Am] 2005;87-A:2456\u201363.","DOI":"10.2106\/00004623-200511000-00012"},{"key":"R37","doi-asserted-by":"crossref","unstructured":"Dowd JE, Kindsfater K, Barrett WP, Southworth C, Dalury DF. Large femoral heads can help reduce risk of dislocation in THR [abstract]. http:\/\/www.aaos.org\/education\/anmt2008\/podium.cfor?Prevent=60 (date last accessed 20 October 2009).","DOI":"10.1016\/j.arth.2008.01.231"},{"key":"R38","doi-asserted-by":"crossref","unstructured":"Beaule PE, Schmalzried TP, Udomkiat P, Amstutz HC. Jumbo femoral head for the treatment of recurrent dislocation following total hip replacement. J Bone Joint Surg [Am] 2002;84-A:256\u201363.","DOI":"10.2106\/00004623-200202000-00013"},{"key":"R39","doi-asserted-by":"crossref","unstructured":"Engh CA, Hopper RH Jr, Engh CA Jr. Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty 2004;19(Suppl 2):54\u201360.","DOI":"10.1016\/j.arth.2004.06.004"},{"key":"R40","unstructured":"Dorr LD. http:\/\/www.csengerilaw.com\/drDorrLetter.html.2008 (date last accessed 17 October 2009)."},{"key":"R41","unstructured":"K\u00e4rrholm J, Garellick G, Herberts P. Annual Report 2006: Swedish Hip Arthroplasty Register. 2007. http:\/\/www.jru.orthop.gu.se\/ (date last accessed 20 October 2009)."},{"key":"R42","unstructured":"Panousis K, Meek R, Roberts P, Grigoris P. The Durom hip resurfacing: results at an average follow up of 4.6 years. http:\/\/www.efort.org\/cdrom2008\/f183.pdf (date last accessed 20 October 2009)."},{"key":"R43","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B4.18054"},{"key":"R44","doi-asserted-by":"crossref","unstructured":"Mont MA, Schmalzried TP. Modern metal-on-metal hip resurfacing: important observations from the first ten years. J Bone Joint Surg [Am] 2008;90-A(Suppl 3):3\u201311.","DOI":"10.2106\/JBJS.H.00750"},{"key":"R45","doi-asserted-by":"crossref","unstructured":"Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clin Orthop 1980;150:263\u201370.","DOI":"10.1097\/00003086-198007000-00045"},{"key":"R46","doi-asserted-by":"crossref","unstructured":"Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC, Kent GM. The effect of porous surface configuration on the tensile stength of fixation of implants by bone ingrowth. Clin Orthop 1980;149:291\u20138.","DOI":"10.1097\/00003086-198006000-00040"},{"key":"R47","doi-asserted-by":"crossref","unstructured":"Cood SD, Walsh KA, Haddad RJ Jr. Interface mechanics and bone growth into porous Co-Cr-Mo alloy implants. Clin Orthop 1985;193:271\u201380.","DOI":"10.1097\/00003086-198503000-00037"},{"key":"R48","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820100304"},{"key":"R49","doi-asserted-by":"crossref","unstructured":"Welsh RP, Pilliar RM, Macnab I. Surgical implants: the role of surface porosity in fixation to bone and acrylic. J Bone Joint Surg [Am] 1971;53-A:963\u201377.","DOI":"10.2106\/00004623-197153050-00011"},{"key":"R50","unstructured":"Ala Eddine T, Remy F, Chantelot C, et al. Anterior iliopsoas impingement after total hip arthroplasty: diagnosis and conservative treatment in 9 cases. Rev Chir Orthop Reparatrice Appar Mot 2001;87:815\u201319 (in French)."},{"key":"R51","unstructured":"Bricteaux S, Beguin L, Fessy MH. Iliopsoas impingement in 12 patients with a total hip arthroplasty. Rev Chir Orthop Reparatrice Appar Mot 2001;87:820\u20135 (in French)."},{"key":"R52","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-007-0062-x"},{"key":"R53","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B8.19208"},{"key":"R54","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B7.0840991"},{"key":"R55","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-006-0084-6"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.92B2.22653","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.92B2.22653","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.92B2.22653","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T17:59:55Z","timestamp":1629136795000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.92B2.22653"}},"subtitle":["EARLY RESULTS WITH A LARGE-DIAMETER METAL-ON-METAL BEARING"],"short-title":[],"issued":{"date-parts":[[2010,2]]},"references-count":55,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2010,2]]}},"alternative-id":["10.1302\/0301-620X.92B2.22653"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.92b2.22653","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,2]]}}}