{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T07:03:40Z","timestamp":1789196620172,"version":"build-2803163510"},"reference-count":27,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"3","license":[{"start":{"date-parts":[[2010,3,1]],"date-time":"2010-03-01T00:00:00Z","timestamp":1267401600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2010,3]]},"abstract":"<jats:p> The presence of pseudotumours, which are soft-tissue masses relating to the hip, after metal-on-metal hip resurfacing arthroplasty has been associated with elevated levels of metal ions in serum, suggesting that pseudotumours occur when there is increased wear. We aimed to quantify the wear in vivo of implants revised for pseudotumours (eight) and of a control group of implants (22) revised for other reasons of failure. <\/jats:p><jats:p> We found that the implant group with pseudotumours had a significantly higher rate of median linear wear of the femoral component at 8.1 \u03bcm\/year (2.75 to 25.4) than the 1.79 \u03bcm\/year (0.82 to 4.15; p = 0.002) of the non-pseudotumour group. For the acetabular component a significantly higher rate of median linear wear of 7.36 \u03bcm\/year (1.61 to 24.9) was observed in the pseudotumour group compared with 1.28 \u03bcm\/year (0.81 to 3.33, p = 0.001) in the other group. Wear of the acetabular component in the pseudotumour group always involved the edge of the implant, indicating that edge-loading had occurred. <\/jats:p><jats:p> Our findings are the first direct evidence that pseudotumour is associated with increased wear at the metal-on-metal articulation. Furthermore, edge-loading with the loss of fluid-film lubrication may be an important mechanism of generation of wear in patients with a pseudotumour. <\/jats:p>","DOI":"10.1302\/0301-620x.92b3.23281","type":"journal-article","created":{"date-parts":[[2010,3,1]],"date-time":"2010-03-01T00:12:33Z","timestamp":1267402353000},"page":"356-361","source":"Crossref","is-referenced-by-count":170,"title":["Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours"],"prefix":"10.1302","volume":"92-B","author":[{"given":"Y. -M.","family":"Kwon","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts 02114, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Glyn-Jones","sequence":"additional","affiliation":[{"name":"Deparment of Orthopaedics, Rheumatology and Musculoskeletal Sciences Nuffield Orthopaedic Centre, Headington, Oxford OX3 7LD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. J.","family":"Simpson","sequence":"additional","affiliation":[{"name":"Deparment of Orthopaedics, Rheumatology and Musculoskeletal Sciences Nuffield Orthopaedic Centre, Headington, Oxford OX3 7LD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Kamali","sequence":"additional","affiliation":[{"name":"Smith & Nephew Orthopaedics Ltd., Implant Development Centre, Warwick CV34 6WG, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"McLardy-Smith","sequence":"additional","affiliation":[{"name":"Deparment of Orthopaedics, Rheumatology and Musculoskeletal Sciences Nuffield Orthopaedic Centre, Headington, Oxford OX3 7LD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H. S.","family":"Gill","sequence":"additional","affiliation":[{"name":"Deparment of Orthopaedics, Rheumatology and Musculoskeletal Sciences Nuffield Orthopaedic Centre, Headington, Oxford OX3 7LD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. W.","family":"Murray","sequence":"additional","affiliation":[{"name":"Deparment of Orthopaedics, Rheumatology and Musculoskeletal Sciences Nuffield Orthopaedic Centre, Headington, Oxford OX3 7LD, UK."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"R1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200301000-00039"},{"key":"R2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.81B1.0810046"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Shimmin A, Beaule PE, Campbell P. Metal-on-metal hip resurfacing arthroplasty. J Bone Joint Surg [Am] 2008;90-A:637\u201354.","DOI":"10.2106\/JBJS.G.01012"},{"key":"R4","unstructured":"No authors listed. National Joint Registry England and Wales Annual Report. 2008. http:\/\/www.njrcentre.org.uk (date last accessed 20 December 2009)."},{"key":"R5","unstructured":"No authors listed. Australian Orthopaedic Association National Joint Replacement Registry Annual Report, 2008. http:\/\/www.aoa.org.au (date last accessed 20 December 2009)."},{"key":"R6","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B7.20213"},{"key":"R7","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.91B8.22562"},{"key":"R8","doi-asserted-by":"publisher","DOI":"10.1007\/s00428-008-0659-9"},{"key":"R9","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.09.024"},{"key":"R10","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2006.10.002"},{"key":"R11","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B3.16748"},{"key":"R12","doi-asserted-by":"crossref","unstructured":"Kwon YM, Ostlere S, McLardy-Smith P, et al. Metal ion levels in asymptomatic pseudotumours associated with metal-on-metal hip resurfacings (abstract). Procs 55th Orthopaedic Research Society Annual Meeting, 2009.","DOI":"10.1016\/S0276-1092(09)79456-8"},{"key":"R13","doi-asserted-by":"crossref","unstructured":"Gill HS, Pandit H, Glyn-Jones S, et al. Pseudotumours associated with metal-on-metal hip resurfacings (abstract). Procs 54th Orthopaedic Research Society Annual Meeting, 2008.","DOI":"10.1302\/0301-620X.90B7.20213"},{"key":"R14","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.00672"},{"key":"R15","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000238777.34939.82"},{"key":"R16","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B10.20533"},{"key":"R17","unstructured":"Hussain A, Counsell L, Kamali A. Clinical effects of edge loading on metal-on-metal hip resurfacings (abstract). Procs British Hip Society Annual Meeting, 2009."},{"key":"R18","unstructured":"Altman DG. Clinical trials. In: Altman DG, ed. Statistics in practice. London: British Medical Association, 1982;452\u201361."},{"key":"R19","doi-asserted-by":"crossref","unstructured":"Taylor S, Manley MT, Sutton K. The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty 2007;22(Suppl 3):47\u201351.","DOI":"10.1016\/j.arth.2007.05.038"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Jacobs JJ, Gilbert JL, Urban RM. Corrosion of metal orthopaedic implants. J Bone Joint Surg [Am] 1998;80-A:268\u201382.","DOI":"10.2106\/00004623-199802000-00015"},{"key":"R21","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2008.06.022"},{"key":"R22","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(02)00422-0"},{"key":"R23","doi-asserted-by":"crossref","unstructured":"Liu F, Jin Z, Roberts P, Grigoris P. Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses. Proc Inst Mech Eng [H] 2006;220:695\u2013704.","DOI":"10.1243\/09544119JEIM172"},{"key":"R24","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B9.20785"},{"key":"R25","doi-asserted-by":"crossref","unstructured":"Dowson D, Hardaker C, Flett M, Isaac GH. A hip joint simulator study of the performance of metal-on-metal joints. Part I: the role of materials. J Arthroplasty 2004;19(Suppl 3):118\u201323.","DOI":"10.1016\/j.arth.2004.09.015"},{"key":"R26","doi-asserted-by":"crossref","unstructured":"Back DL, Young DA, Shimmin AJ. How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Clin Orthop 2005;438:177\u201381.","DOI":"10.1097\/01.blo.0000166901.84323.5d"},{"key":"R27","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199912000-00003"}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.92B3.23281","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.92B3.23281","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.92B3.23281","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T17:54:39Z","timestamp":1629136479000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.92B3.23281"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,3]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,3]]}},"alternative-id":["10.1302\/0301-620X.92B3.23281"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.92b3.23281","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,3]]}}}