{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T17:39:12Z","timestamp":1775151552084,"version":"3.50.1"},"reference-count":33,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"10","license":[{"start":{"date-parts":[[2011,10,1]],"date-time":"2011-10-01T00:00:00Z","timestamp":1317427200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["The Journal of Bone and Joint Surgery. British volume"],"published-print":{"date-parts":[[2011,10]]},"abstract":"<jats:p> High-flexion total knee replacement (TKR) designs have been introduced to improve flexion after TKR. Although the early results of such designs were promising, recent literature has raised concerns about the incidence of early loosening of the femoral component. We compared the minimum force required to cause femoral component loosening for six high-flexion and six conventional TKR designs in a laboratory experiment. <\/jats:p><jats:p> Each TKR design was implanted in a femoral bone model and placed in a loading frame in 135\u00b0 of flexion. Loosening of the femoral component was induced by moving the tibial component at a constant rate of displacement while maintaining the same angle of flexion. A stereophotogrammetric system registered the relative movement between the femoral component and the underlying bone until loosening occurred. <\/jats:p><jats:p> Compared with high-flexion designs, conventional TKR designs required a significantly higher force before loosening occurred (p &lt; 0.001). High-flexion designs with closed box geometry required significantly higher loosening forces than high-flexion designs with open box geometry (p = 0.0478). The presence of pegs further contributed to the fixation strength of components. <\/jats:p><jats:p> We conclude that high-flexion designs have a greater risk for femoral component loosening than conventional TKR designs. We believe this is attributable to the absence of femoral load sharing between the prosthetic component and the condylar bone during flexion. <\/jats:p>","DOI":"10.1302\/0301-620x.93b10.25436","type":"journal-article","created":{"date-parts":[[2011,10,3]],"date-time":"2011-10-03T19:39:45Z","timestamp":1317670785000},"page":"1355-1361","source":"Crossref","is-referenced-by-count":29,"title":["Femoral component loosening in high-flexion total knee replacement"],"prefix":"10.1302","volume":"93-B","author":[{"given":"P.","family":"Bollars","sequence":"first","affiliation":[{"name":"University Hospital Leuven, Department\rof Orthopaedic Surgery, Weligerveld 1, 3212\rPellenberg, Belgium."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.-P.","family":"Luyckx","sequence":"additional","affiliation":[{"name":"European Centre for Knee Research, Smith & Nephew Orthopaedics, Technologielaan 11 bis, 3001 Leuven, Belgium."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Innocenti","sequence":"additional","affiliation":[{"name":"European Centre for Knee Research, Smith & Nephew Orthopaedics, Technologielaan 11 bis, 3001 Leuven, Belgium."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Labey","sequence":"additional","affiliation":[{"name":"European Centre for Knee Research, Smith & Nephew Orthopaedics, Technologielaan 11 bis, 3001 Leuven, Belgium."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Victor","sequence":"additional","affiliation":[{"name":"AZ St Lucas, Sint-Lucaslaan\r29, 8310 Brugge, Belgium."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Bellemans","sequence":"additional","affiliation":[{"name":"University Hospital Leuven, Department\rof Orthopaedic Surgery, Weligerveld 1, 3212\rPellenberg, Belgium."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"42","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1994.03510410061034"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199610000-00012"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000063121.39522.19"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000150130.03519.fb"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1054\/arth.2002.32688"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2004.09.053"},{"key":"r7","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1097\/BLO.0b013e318157e478","volume":"464","author":"Sharma A","year":"2007","journal-title":"Clin Orthop"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-009-1127-9"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B1.19702"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.92B10.23199"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.92B5.24129"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.89B11.19840"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000238843.11176.42"},{"key":"r14","doi-asserted-by":"publisher","DOI":"10.1123\/jab.22.4.305"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.00606"},{"key":"r16","first-page":"54","volume":"18","author":"Arnout N","year":"2010","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"r17","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200211000-00035"},{"key":"r18","doi-asserted-by":"publisher","DOI":"10.1299\/jbse.2.237"},{"key":"r19","first-page":"120","volume":"87","author":"Morra EA","year":"2005","journal-title":"J Bone Joint Surg [Am]"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B1.0840050"},{"key":"r21","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-009-0865-3"},{"key":"r22","first-page":"64","volume":"309","author":"Hirsch HS","year":"1994","journal-title":"Clin Orthop"},{"key":"r23","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)90025-0"},{"key":"r24","first-page":":Epub.","author":"Scuderi GR","journal-title":"J Bone Joint Surg [Br]"},{"key":"r25","first-page":"307","volume":"18","author":"Lee MC","year":"2010","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"r26","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2008.11.015"},{"key":"r27","first-page":"285","volume":"194","author":"King TV","year":"1985","journal-title":"Clin Orthop"},{"key":"r28","doi-asserted-by":"publisher","DOI":"10.1002\/jor.21363"},{"key":"r29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.02.027"},{"key":"r30","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000238792.36725.1e"},{"key":"r31","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1002\/jor.20893","volume":"28","author":"Miller MA","year":"2010","journal-title":"J Orthop Res"},{"key":"r32","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2008.12.015"},{"key":"r33","unstructured":"Bedair H, Tormey M, Della Valle CJ, Berger RA. The high failure rate of a high-flex total knee arthroplasty design [abstract 434]. Procs AAOS 2010 Annual Meeting:432-3."}],"container-title":["The Journal of Bone and Joint Surgery. British volume"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.93B10.25436","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.93B10.25436","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.93B10.25436","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,16]],"date-time":"2021-08-16T19:01:44Z","timestamp":1629140504000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.93B10.25436"}},"subtitle":["An <i>in vitro<\/i> comparison of high-flexion <i>versus<\/i> conventional designs"],"short-title":[],"issued":{"date-parts":[[2011,10]]},"references-count":33,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2011,10]]}},"alternative-id":["10.1302\/0301-620X.93B10.25436"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.93b10.25436","relation":{},"ISSN":["0301-620X","2044-5377"],"issn-type":[{"value":"0301-620X","type":"print"},{"value":"2044-5377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,10]]}}}