{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T11:05:47Z","timestamp":1785323147564,"version":"3.55.0"},"reference-count":33,"publisher":"British Editorial Society of Bone & Joint Surgery","issue":"8","license":[{"start":{"date-parts":[[2016,8,1]],"date-time":"2016-08-01T00:00:00Z","timestamp":1470009600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/online.boneandjoint.org.uk\/TDM"}],"content-domain":{"domain":["online.boneandjoint.org.uk"],"crossmark-restriction":true},"short-container-title":["The Bone &amp; Joint Journal"],"published-print":{"date-parts":[[2016,8]]},"abstract":"<jats:sec><jats:title>Aims<\/jats:title><jats:p> Loosening of pedicle screws is a major complication of posterior spinal stabilisation, especially in the osteoporotic spine. Our aim was to evaluate the effect of cement augmentation compared with extended dorsal instrumentation on the stability of posterior spinal fixation. <\/jats:p><\/jats:sec><jats:sec><jats:title>Materials and Methods<\/jats:title><jats:p> A total of 12 osteoporotic human cadaveric spines (T11-L3) were randomised by bone mineral density into two groups and instrumented with pedicle screws: group I (SHORT) separated T12 or L2 and group II (EXTENDED) specimen consisting of T11\/12 to L2\/3. Screws were augmented with cement unilaterally in each vertebra. Fatigue testing was performed using a cranial-caudal sinusoidal, cyclic (1.0 Hz) load with stepwise increasing peak force. <\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p> Augmentation showed no significant increase in the mean cycles to failure and fatigue force (SHORT p = 0.067; EXTENDED p = 0.239). Extending the instrumentation resulted in a significantly increased number of cycles to failure and a significantly higher fatigue force compared with the SHORT instrumentation (EXTENDED non-augmented + 76%, p &lt; 0.001; EXTENDED augmented + 87%, p &lt; 0.001). <\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p> The stabilising effect of cement augmentation of pedicle screws might not be as beneficial as expected from biomechanical pull-out tests. Lengthening the dorsal instrumentation results in a much higher increase of stability during fatigue testing in the osteoporotic spine compared with cement augmentation. Cite this article: Bone Joint J 2016;98-B:1099\u20131105. <\/jats:p><\/jats:sec>","DOI":"10.1302\/0301-620x.98b8.37413","type":"journal-article","created":{"date-parts":[[2016,8,1]],"date-time":"2016-08-01T12:13:09Z","timestamp":1470053589000},"page":"1099-1105","update-policy":"https:\/\/doi.org\/10.1302\/crossmark-policy","source":"Crossref","is-referenced-by-count":31,"title":["Cement augmentation <i>versus<\/i> extended dorsal instrumentation in the treatment of osteoporotic vertebral fractures"],"prefix":"10.1302","volume":"98-B","author":[{"given":"L.","family":"Weiser","sequence":"first","affiliation":[{"name":"University Medical Center G\u00f6ttingen, G\u00f6ttingen, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Dreimann","sequence":"additional","affiliation":[{"name":"University Medical Center Hamburg-Eppendorf, Hamburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Huber","sequence":"additional","affiliation":[{"name":"Institute of Biomechanics, TUHH Hamburg\rUniversity of Technology, Hamburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Sellenschloh","sequence":"additional","affiliation":[{"name":"Institute of Biomechanics, TUHH Hamburg\rUniversity of Technology, Hamburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"P\u00fcschel","sequence":"additional","affiliation":[{"name":"Institute of Forensic Medicine, University\rMedical Center Hamburg-Eppendorf, Hamburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. M.","family":"Morlock","sequence":"additional","affiliation":[{"name":"Institute of Biomechanics, TUHH Hamburg\rUniversity of Technology, Hamburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. M.","family":"Rueger","sequence":"additional","affiliation":[{"name":"University Medical Center Hamburg-Eppendorf, Hamburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W.","family":"Lehmann","sequence":"additional","affiliation":[{"name":"University Medical Center G\u00f6ttingen, G\u00f6ttingen, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"42","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.1359\/jbmr.061113"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.92B8.24237"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200010000-00013"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2012.10.041"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199411000-00008"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199111000-00015"},{"key":"r7","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-015-3768-6"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0b013e318246ae8a"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0b013e318228bbed"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-015-4001-3"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3182740e56"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-014-3476-7"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181d449ec"},{"key":"r14","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199311000-00015"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199412150-00007"},{"key":"r16","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200101150-00017"},{"key":"r17","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-007-0310-5"},{"key":"r18","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-015-2383-y"},{"key":"r19","doi-asserted-by":"publisher","DOI":"10.1007\/s005860050175"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1097\/01.bsd.0000095827.98982.88"},{"key":"r21","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-199302000-00002"},{"key":"r22","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000001058"},{"key":"r23","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181882cac"},{"key":"r24","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9290(96)00103-0"},{"key":"r25","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199103001-00021"},{"key":"r26","doi-asserted-by":"publisher","DOI":"10.1097\/00024720-200306000-00002"},{"key":"r27","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2014.09.004"},{"key":"r28","doi-asserted-by":"publisher","DOI":"10.1097\/00002517-199209000-00012"},{"key":"r29","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199208001-00018"},{"key":"r30","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199303010-00008"},{"key":"r31","doi-asserted-by":"publisher","DOI":"10.1097\/01.bsd.0000149874.61397.38"},{"key":"r32","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0000000000000178"},{"key":"r33","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-014-3711-x"}],"container-title":["The Bone &amp; Joint Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.98B8.37413","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/0301-620X.98B8.37413","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/0301-620X.98B8.37413","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,19]],"date-time":"2021-10-19T10:46:59Z","timestamp":1634640419000},"score":1,"resource":{"primary":{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/10.1302\/0301-620X.98B8.37413"}},"subtitle":["a biomechanical comparison"],"short-title":[],"issued":{"date-parts":[[2016,8]]},"references-count":33,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2016,8]]}},"alternative-id":["10.1302\/0301-620X.98B8.37413"],"URL":"https:\/\/doi.org\/10.1302\/0301-620x.98b8.37413","relation":{},"ISSN":["2049-4394","2049-4408"],"issn-type":[{"value":"2049-4394","type":"print"},{"value":"2049-4408","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,8]]},"assertion":[{"value":"2015-10-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-04-05","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-08-01","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}