{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T07:21:41Z","timestamp":1792653701268,"version":"4.5.0"},"reference-count":43,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2018,10,1]],"date-time":"2018-10-01T00:00:00Z","timestamp":1538352000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"},{"start":{"date-parts":[[2018,10,1]],"date-time":"2018-10-01T00:00:00Z","timestamp":1538352000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Journal of Children's Orthopaedics"],"published-print":{"date-parts":[[2018,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Exposure to ionizing radiation is a concern for children during intraoperative imaging. We aimed to assess the radiation exposure to the paediatric patient with 2D and 3D imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      To evaluate the radiation exposure, patient absorbed doses to the organs were measured in an anthropomorphic phantom representing a five-year-old child, using thermoluminescent dosimeters. For comparative purposes, organ doses were measured using a C-arm for one minute of fluoroscopy and one acquisition with an O-arm. The cone-beam was centred on the pelvis. Direct and scattered irradiations were measured and compared (Student's\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      -test). Skin entrance dose rates were also evaluated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec sec-type=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      All radiation doses were expressed in \u00b5Gy. Direct radiation doses of pelvic organs were between 631.22 and 1691.87 for the O-arm and between 214.08 and 737.51 for the C-arm, and were not significant (p = 0.07). Close scattered radiation on abdominal organs were between 25.11 and 114.85 for the O-arm and between 8.03 and 55.34 for the C-arm, and were not significant (p = 0.07). Far scattered radiation doses on thorax, neck and head varied from 0.86 to 6.42 for the O-arm and from 0.04 to 3.08 for the C-arm, and were significant (p = 0.02). The dose rate at the skin entrance was 328.58 \u00b5Gy.s\n                      <jats:sup>\u22121<\/jats:sup>\n                      for the O-arm and 1.90 with the C-arm.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>During imaging of the pelvis, absorbed doses for a 3D O-arm acquisition were higher than with one minute fluoroscopy with the C-arm. Further clinical studies comparing effective doses are needed to assess ionizing risks of the intraoperative imaging systems in children.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1302\/1863-2548.12.180016","type":"journal-article","created":{"date-parts":[[2018,9,5]],"date-time":"2018-09-05T11:22:55Z","timestamp":1536146575000},"page":"550-557","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":16,"title":["Intraoperative 2D C-arm and 3D O-arm in children: A comparative phantom study"],"prefix":"10.1177","volume":"12","author":[{"given":"M.","family":"Prod'homme","sequence":"first","affiliation":[{"name":"Medical University of Geneva, Geneva, Switzerland"},{"name":"Paediatric Orthopaedic Division, Geneva University Hospital (HUG), Geneva, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Sans-Merce","sequence":"additional","affiliation":[{"name":"Radiology Division, Geneva University Hospital (HUG), Geneva, Switzerland"},{"name":"Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"N.","family":"Pitteloud","sequence":"additional","affiliation":[{"name":"Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland"},{"name":"Physics Section, University of Geneva, Geneva, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Damet","sequence":"additional","affiliation":[{"name":"Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland"},{"name":"Department of Radiology, University of Otago, Christchurch, New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Lascombes","sequence":"additional","affiliation":[{"name":"Medical University of Geneva, Geneva, Switzerland"},{"name":"Paediatric Orthopaedic Division, Geneva University Hospital (HUG), Geneva, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2018,10]]},"reference":[{"key":"e_1_3_2_2_2","unstructured":"National Research Council. Health risks from exposure to low levels of ionizing radiation: BEIR VII phase 2. National Academies Press 2006 April 23."},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-006-0191-5"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.aje.a116610"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1667\/0033-7587(2002)158[0220:REOBCR]2.0.CO;2"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.2307\/3579984"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1667\/0033-7587(2002)157[0410:SCAXRT]2.0.CO;2"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1289\/ehp.00108495"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1001\/archinternmed.2009.427"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004032-200307000-00011"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3171\/2016.11.PEDS16412"},{"key":"e_1_3_2_12_2","unstructured":"Medtronic. O-arm user manual MN. http:\/\/www.medtronic.com\/content\/dam\/medtronic-com\/us-en\/newsroom\/media-resources\/media-kits\/o-arm-imaging-system\/documents\/O-Arm%20Backgrounder.pdf (date last accessed 11December2017)."},{"key":"e_1_3_2_13_2","unstructured":"Medtronic. StealthStation user manual MN. http:\/\/www.medtronic.com\/us-en\/healthcare-professionals\/products\/spinal-orthopaedic\/surgical-navigation-imaging\/spine-surgery-imaging-surgical-navigation\/manuals-technical-resources.html (date last accessed 11December2017)."},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-015-4012-0"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e318271b1fa"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0000000000000504"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0b013e318211fdea"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-012-2396-0"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0000000000000493"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-016-4773-0"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0000000000000608"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200010150-00016"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.icrp.2012.03.001"},{"key":"e_1_3_2_24_2","first-page":"168","volume-title":"NCRP","author":"National Council on Radiation Protection and Measurements","year":"2010","unstructured":"National Council on Radiation Protection and Measurements. Radiation dose management for fluoroscopically guided interventional medical procedures. Bethesda, MD: NCRP 168; 2010."},{"key":"e_1_3_2_25_2","unstructured":"CIRS. ATOM dosimetry phantoms VA. http:\/\/www.cirsinc.com\/file\/Products\/701_706\/701%20706%20ATOM%20PB%20110615.pdf (date last accessed 11December2017)."},{"key":"e_1_3_2_26_2","unstructured":"International Commission on Radiological Protection. Report on the task group on reference man. Publication 23 Ottawa. http:\/\/journals.sagepub.com\/doi\/pdf\/10.1016\/S0074-2740%2875%2980015-8 (date last accessed 11December2017)."},{"key":"e_1_3_2_27_2","unstructured":"ICRU. P. computational models in Therapy Diagnosis and Protection. International Commission on Radiation Units and Measurements Report. 1992; 48."},{"key":"e_1_3_2_28_2","unstructured":"Ziehm Imaging. Ziehm Vision 26366-5_4.12_EN_00 user manual. http:\/\/www.wemed1.com\/downloads\/dl\/file\/id\/7960\/product\/10537\/manual_for_xrc_z_vision_r.pdf (date last accessed 11December2017)."},{"key":"e_1_3_2_29_2","unstructured":"Joint Committee for Guides in Metrology. Guide to the expression of uncertainty in measurement. International Organization for Standardization Geneva. https:\/\/www.bipm.org\/utils\/common\/documents\/jcgm\/JCGM_100_2008_E.pdf (date last accessed 11December2017)."},{"key":"e_1_3_2_30_2","unstructured":"RadCal. 20X6 Chambers \u2013 Technical Specifications. http:\/\/www.testmart.com\/webdata\/mfr_pdfs\/RADCAL\/ew-20x6-chamber-spec-sheet-web-11-2-28.pdf (date last accessed 11December2017)."},{"key":"e_1_3_2_31_2","first-page":"305","article-title":"Dosimetric characterization of a cone-beam O-arm imaging system","volume":"17","author":"Zhang J","year":"2009","unstructured":"Zhang J, Weir V, Fajardo L, . Dosimetric characterization of a cone-beam O-arm imaging system. J Xray Sci Technol 2009; 17: 305\u2013 317.","journal-title":"J Xray Sci Technol"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-011-1588-8"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000000363"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.1435"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-013-1686-9"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPB.0b013e328333997a"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e31815e6308"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-011-1402-8"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2016.05.005"},{"key":"e_1_3_2_40_2","first-page":"1631","article-title":"Clinical application of computer navigation in physeal bridge resection in pediatric partial epiphyseal plate closure","volume":"94","author":"Dong Y","year":"2014","unstructured":"Dong Y, L\u00fc X, Zhang J, Guo Y. Clinical application of computer navigation in physeal bridge resection in pediatric partial epiphyseal plate closure. Zhonghua Yi Xue Za Zhi 2014; 94: 1631\u2013 1634.","journal-title":"Zhonghua Yi Xue Za Zhi"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.1097\/BPO.0b013e318274561b"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2014.06.003"},{"key":"e_1_3_2_43_2","unstructured":"ORaP RO814. Ordonnance sur la radioprotection. https:\/\/www.admin.ch\/opc\/fr\/classified-compilation\/19940157\/index.html (date last accessed 11December2017)."},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2016.05.025"}],"container-title":["Journal of Children's Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1302\/1863-2548.12.180016","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1302\/1863-2548.12.180016","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1302\/1863-2548.12.180016","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T15:05:51Z","timestamp":1777388751000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1302\/1863-2548.12.180016"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10]]},"references-count":43,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["10.1302\/1863-2548.12.180016"],"URL":"https:\/\/doi.org\/10.1302\/1863-2548.12.180016","relation":{},"ISSN":["1863-2521","1863-2548"],"issn-type":[{"value":"1863-2521","type":"print"},{"value":"1863-2548","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10]]}}}