{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,15]],"date-time":"2026-11-15T04:25:23Z","timestamp":1794716723818,"version":"4.9.1"},"reference-count":69,"publisher":"Bioscientifica","issue":"4","license":[{"start":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T00:00:00Z","timestamp":1770940800000},"content-version":"vor","delay-in-days":2510,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["journals.bioscientifica.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2019,4,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Possible indications for a rotating hinge or pure hinge implant in primary total knee arthroplasty (TKA) include collateral ligament insufficiency, severe varus or valgus deformity (&amp;gt; 20\u00b0) with relevant soft-tissue release, relevant bone loss, including insertions of collateral ligaments, gross flexion-extension gap imbalance, ankylosis and hyperlaxity. The use of hinged implants in primary TKA should be limited to the aforementioned selected indications, especially for elderly patients. Potential indications for a rotating hinge or pure hinge implant in revision TKA include infection, aseptic loosening, instability and bone loss. Rotating hinge knee implants have a 10-year survivorship in the range of 51% to 92.5%. Complication rates of rotating hinge knee implants are in the range of 9.2% to 63%, with infection and aseptic loosening as the most common complications. Although the results reported in the literature are inconsistent, clinical results generally depend on the implant design, appropriate technical use and adequate indications. Considering that the revision of implants with long cemented stems can be challenging, in the future it would be better to use shorter stems in modular versions of hinged knee implants.<\/jats:p>\n                  <jats:p>Cite this article: EFORT Open Rev 2019;4:121-132. DOI: 10.1302\/2058-5241.4.180056<\/jats:p>","DOI":"10.1302\/2058-5241.4.180056","type":"journal-article","created":{"date-parts":[[2019,4,25]],"date-time":"2019-04-25T05:54:38Z","timestamp":1556171678000},"page":"121-132","update-policy":"https:\/\/doi.org\/10.1530\/crossmarkpolicy-16","source":"Crossref","is-referenced-by-count":70,"title":["Total knee arthroplasty using hinge joints: Indications and results"],"prefix":"10.1530","volume":"4","author":[{"given":"E. Carlos","family":"Rodr\u00edguez-Merch\u00e1n","sequence":"first","affiliation":[{"name":"1Department of Orthopaedic Surgery, \u201cLa Paz\u201d University Hospital-IdiPaz, Madrid, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"416","published-online":{"date-parts":[[2019,4,25]]},"reference":[{"key":"2026070711243007500_bibr1-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1302\/0301-620X.57B1.59","article-title":"The Walldius hinge arthroplasty","volume":"57-B","author":"Phillips","year":"1975","journal-title":"J Bone Joint Surg [Br]"},{"key":"2026070711243007500_bibr2-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1007\/BF00415100","article-title":"[Total knee replacement using the Walldius hinge joint (author\u2019s transl)]","volume":"88","author":"K\u00fcsswetter","year":"1977","journal-title":"Arch Orthop Unfallchir"},{"issue":"120","key":"2026070711243007500_bibr3-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/00003086-197610000-00009","article-title":"Guepar hinge prosthesis: complications and results with two years\u2019 follow-up","author":"Deburge","year":"1976","journal-title":"Clin Orthop Relat Res"},{"issue":"155","key":"2026070711243007500_bibr4-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1097\/00003086-198103000-00022","article-title":"Functional outcome of GUEPAR hinge knee arthroplasty evaluated with ARAMIS","author":"Schurman","year":"1981","journal-title":"Clin Orthop Relat Res"},{"key":"2026070711243007500_bibr5-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1302\/0301-620X.63B2.7217152","article-title":"Guepar total knee prosthesis. Experience at the Vancouver General Hospital","volume":"63-B","author":"leNobel","year":"1981","journal-title":"J Bone Joint Surg [Br]"},{"key":"2026070711243007500_bibr6-2058-5241.4.180056","first-page":"465","article-title":"Hinge prosthesis of the knee. Apropos of 185 cases. [Article in French]","volume":"69","author":"Duquennoy","year":"1983","journal-title":"Rev Chir Orthop Repar Appar Mot"},{"key":"2026070711243007500_bibr7-2058-5241.4.180056","first-page":"278","article-title":"Hinge total knee replacement revisited","volume":"40","author":"Cameron","year":"1997","journal-title":"Can J Surg"},{"key":"2026070711243007500_bibr8-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.otsr.2013.12.012","article-title":"GUEPAR hinge knee prosthesis","volume":"100","author":"Aubriot","year":"2014","journal-title":"Orthop Traumatol Surg Res"},{"key":"2026070711243007500_bibr9-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"489","DOI":"10.2106\/00004623-198769040-00003","article-title":"Kinematic rotating-hinge total knee arthroplasty","volume":"69","author":"Rand","year":"1987","journal-title":"J Bone Joint Surg [Am]"},{"key":"2026070711243007500_bibr10-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"647","DOI":"10.3928\/0147-7447-19890501-05","article-title":"Total knee arthroplasty using the kinematic rotating hinge prosthesis","volume":"12","author":"Shaw","year":"1989","journal-title":"Orthopedics"},{"key":"2026070711243007500_bibr11-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1097\/00003086-199703000-00024","article-title":"In vivo rotational stability of the kinematic rotating hinge knee prosthesis","volume":"336","author":"Kabo","year":"1997","journal-title":"Clin Orthop Relat Res"},{"key":"2026070711243007500_bibr12-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/j.arth.2007.05.055","article-title":"The role of the rotating hinge prosthesis in the salvage arthroplasty setting","volume":"23","author":"Deehan","year":"2008","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr13-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1055\/s-2008-1044458","article-title":"[Is the implantation of hinged knee joint prostheses still justifiable today? 15 years\u2019 experience using the Blauth knee joint prosthesis]","volume":"126","author":"Hassenpflug","year":"1988","journal-title":"Z Orthop Ihre Grenzgeb"},{"key":"2026070711243007500_bibr14-2058-5241.4.180056","first-page":"206","article-title":"[Hinge endoprosthesis of the knee joint. Long-term results based on the Blauth prosthesis]","volume":"20","author":"Blauth","year":"1991","journal-title":"Orthopade"},{"key":"2026070711243007500_bibr15-2058-5241.4.180056","first-page":"375","article-title":"Rotaflex total knee arthroplasty: a report of two prosthetic failures at the hinge mechanism","volume":"39","author":"Wilkinson","year":"1994","journal-title":"J R Coll Surg Edinb"},{"key":"2026070711243007500_bibr16-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/S0883-5403(98)90005-5","article-title":"Problems with the Rotaflex: a 10 year review of a rotating hinge prosthesis","volume":"13","author":"David","year":"1998","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr17-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1054\/arth.2000.9056","article-title":"The use of a modular rotating hinge component in salvage revision total knee arthroplasty","volume":"15","author":"Barrack","year":"2000","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr18-2058-5241.4.180056","first-page":"S80","article-title":"Total knee arthroplasty with modular rotating-platform hinge","volume":"29","author":"Jones","year":"2006","journal-title":"Orthopedics"},{"key":"2026070711243007500_bibr19-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1016\/j.arth.2011.08.015","article-title":"Follow-up of a modular rotating hinge knee system in salvage revision total knee arthroplasty","volume":"27","author":"Neumann","year":"2012","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr20-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1054\/arth.2001.21498","article-title":"Total knee arthroplasty using the S-ROM mobile-bearing hinge prosthesis","volume":"16","author":"Jones","year":"2001","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr21-2058-5241.4.180056","first-page":"167","article-title":"Anterior knee symptoms after S-ROM hinge implantation","volume":"72","author":"Deehan","year":"2014","journal-title":"Bull Hosp Jt Dis (2013)"},{"key":"2026070711243007500_bibr22-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1016\/j.knee.2004.03.001","article-title":"Salvage revision total knee replacement using the Endo-Model rotating hinge prosthesis","volume":"11","author":"Pradhan","year":"2004","journal-title":"Knee"},{"key":"2026070711243007500_bibr23-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1302\/0301-620X.86B6.14708","article-title":"Medium-term results with a primary cemented rotating-hinge total knee replacement. A 7- to 15-year follow-up","volume":"86","author":"Petrou","year":"2004","journal-title":"J Bone Joint Surg [Br]"},{"key":"2026070711243007500_bibr24-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/j.arth.2006.11.020","article-title":"Dislocation of rotating-hinge knee prostheses with antidislocation mechanism","volume":"23","author":"Pacha-Vicente","year":"2008","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr25-2058-5241.4.180056","first-page":"179","article-title":"Application of the Endomodel rotating hinge knee prosthesis for knee osteoarthritis","volume":"17","author":"Mavrodontidis","year":"2008","journal-title":"J Surg Orthop Adv"},{"key":"2026070711243007500_bibr26-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.otsr.2009.07.013","article-title":"Complications following rotating hinge Endo-Modell (Link) knee arthroplasty","volume":"95","author":"Guenoun","year":"2009","journal-title":"Orthop Traumatol Surg Res"},{"key":"2026070711243007500_bibr27-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1007\/s00402-011-1330-5","article-title":"Implant survival and outcome after rotating-hinge total knee revision arthroplasty: a minimum 6-year follow-up","volume":"131","author":"Gudnason","year":"2011","journal-title":"Arch Orthop Trauma Surg"},{"key":"2026070711243007500_bibr28-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s00167-011-1590-1","article-title":"Primary total knee arthroplasty using rotating-hinge prosthesis in severely affected knees","volume":"20","author":"Yang","year":"2012","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026070711243007500_bibr29-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"249391","DOI":"10.1100\/2012\/249391","article-title":"Better outcomes in severe and morbid obese patients (BMI &gt; 35 kg\/m2) in primary Endo-Model rotating-hinge total knee arthroplasty","volume":"2012","author":"Lozano","year":"2012","journal-title":"ScientificWorldJournal"},{"key":"2026070711243007500_bibr30-2058-5241.4.180056","first-page":"e35","article-title":"Mid-term results after implantation of rotating-hinge knee prostheses: primary versus revision","volume":"4","author":"Efe","year":"2012","journal-title":"Orthop Rev (Pavia)"},{"key":"2026070711243007500_bibr31-2058-5241.4.180056","first-page":"e746","article-title":"Results with 98 Endo-Modell rotating hinge prostheses for primary knee arthroplasty","volume":"36","author":"Bistolfi","year":"2013","journal-title":"Orthopedics"},{"key":"2026070711243007500_bibr32-2058-5241.4.180056","first-page":"e1299","article-title":"Endo-Modell rotating-hinge total knee for revision total knee arthroplasty","volume":"36","author":"Bistolfi","year":"2013","journal-title":"Orthopedics"},{"key":"2026070711243007500_bibr33-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1007\/s00402-014-2061-1","article-title":"Total knee arthroplasty with rotating-hinge Endo-Model prosthesis: clinical results in complex primary and revision surgery","volume":"134","author":"Sanguineti","year":"2014","journal-title":"Arch Orthop Trauma Surg"},{"key":"2026070711243007500_bibr34-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.jcot.2014.11.001","article-title":"Revision knee arthroplasty with a rotating-hinge design in elderly patients with instability following total knee arthroplasty","volume":"6","author":"Rodr\u00edguez-Merch\u00e1n","year":"2015","journal-title":"J Clin Orthop Trauma"},{"key":"2026070711243007500_bibr35-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1007\/s00132-015-3193-x","article-title":"The Endo-Model(\u00ae) rotating hinge for rheumatoid knees: functional results in primary and revision surgery","volume":"45","author":"Felli","year":"2016","journal-title":"Orthopade"},{"key":"2026070711243007500_bibr36-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.rbo.2017.01.009","article-title":"Knee arthroplasty with rotating-hinge implant: an option for complex primary cases and revisions","volume":"53","author":"Helito","year":"2018","journal-title":"Rev Bras Ortop"},{"key":"2026070711243007500_bibr37-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"993","DOI":"10.1007\/s00264-011-1462-9","article-title":"Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature","volume":"36","author":"Friesenbichler","year":"2012","journal-title":"Int Orthop"},{"key":"2026070711243007500_bibr38-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"2476","DOI":"10.1007\/s00167-012-1916-7","article-title":"Custom-made rotating hinge total knee replacement in a patient with congenital tibial deficiency avoids the need for amputation","volume":"20","author":"McGrath","year":"2012","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026070711243007500_bibr39-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1302\/0301-620X.94B3.27892","article-title":"Custom rotating-hinge primary total knee arthroplasty in patients with skeletal dysplasia","volume":"94","author":"Sewell","year":"2012","journal-title":"J Bone Joint Surg [Br]"},{"key":"2026070711243007500_bibr40-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1007\/s00402-012-1539-y","article-title":"Custom rotating-hinge total knee replacement in patients with spina bifida and severe neuromuscular dysfunction","volume":"132","author":"Sewell","year":"2012","journal-title":"Arch Orthop Trauma Surg"},{"key":"2026070711243007500_bibr41-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1007\/s00264-014-2572-y","article-title":"Custom rotating hinge total knee arthroplasty in patients with poliomyelitis affected limbs","volume":"39","author":"Rahman","year":"2015","journal-title":"Int Orthop"},{"key":"2026070711243007500_bibr42-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"e325","DOI":"10.3928\/01477447-20120222-34","article-title":"Rotating-hinge total knee for revision total knee arthroplasty","volume":"35","author":"Bistolfi","year":"2012","journal-title":"Orthopedics"},{"key":"2026070711243007500_bibr43-2058-5241.4.180056","first-page":"61","article-title":"Mid-term results of rotating hinge knee prostheses","volume":"78","author":"Rajgopal","year":"2012","journal-title":"Acta Orthop Belg"},{"key":"2026070711243007500_bibr44-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"948520","DOI":"10.1155\/2014\/948520","article-title":"Early results of a new rotating hinge knee implant","volume":"2014","author":"Giurea","year":"2014","journal-title":"BioMed Res Int"},{"key":"2026070711243007500_bibr45-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"7532745","DOI":"10.1155\/2017\/7532745","article-title":"Midterm results of a new rotating hinge knee implant: A 5-year follow-up","volume":"2017","author":"B\u00f6hler","year":"2017","journal-title":"BioMed Res Int"},{"issue":"228","key":"2026070711243007500_bibr46-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/00003086-198803000-00024","article-title":"An evaluation of the mechanical failure modalities of a rotating hinge knee prosthesis","author":"Kester","year":"1988","journal-title":"Clin Orthop Relat Res"},{"key":"2026070711243007500_bibr47-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/00003086-200010000-00023","article-title":"Rotating hinge total knee arthroplasty in severly affected knees","volume":"379","author":"Westrich","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"2026070711243007500_bibr48-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1302\/0301-620X.96B11.34143","article-title":"The role of hinges in primary total knee replacement","volume":"96-B","author":"Gehrke","year":"2014","journal-title":"Bone Joint J"},{"key":"2026070711243007500_bibr49-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.jcot.2017.11.020","article-title":"Rotating hinge prosthesis for complex revision total knee arthroplasty: A review of the literature","volume":"9","author":"Kouk","year":"2018","journal-title":"J Clin Orthop Trauma"},{"key":"2026070711243007500_bibr50-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/S0883-5403(00)90877-5","article-title":"Early catastrophic failure of rotating hinge total knee prosthesis","volume":"15","author":"Wang","year":"2000","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr51-2058-5241.4.180056","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2010.08.008","article-title":"Failure of the tibial insert in a rotating hinge total knee arthroplasty","volume":"26","author":"Schwarzkopf","year":"2011","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr52-2058-5241.4.180056","doi-asserted-by":"crossref","DOI":"10.1016\/j.arth.2012.07.030","article-title":"Failure of the rotating-hinge knee megaprosthesis","volume":"28","author":"Chuang","year":"2013","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr53-2058-5241.4.180056","article-title":"Posterior dislocation of the hinge-post extension in a rotating hinge total knee prosthesis","volume":"2013","author":"Manzano","year":"2013","journal-title":"Case Rep Orthop"},{"key":"2026070711243007500_bibr54-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1007\/s11999-012-2736-2","article-title":"Case report: failure of rotating-hinge total knee prosthesis by disengagement of the hinge-post extension","volume":"471","author":"Biswas","year":"2013","journal-title":"Clin Orthop Relat Res"},{"key":"2026070711243007500_bibr55-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"260","DOI":"10.4055\/cios.2018.10.2.260","article-title":"Three cases of femoral stem failure in rotating hinge revision total knee arthroplasty: causes and surgical considerations","volume":"10","author":"Sandiford","year":"2018","journal-title":"Clin Orthop Surg"},{"key":"2026070711243007500_bibr56-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"448","DOI":"10.2106\/00004623-200303000-00008","article-title":"Dislocation of rotating hinge total knee prostheses. A biomechanical analysis","volume":"85-A","author":"Ward","year":"2003","journal-title":"J Bone Joint Surg [Am]"},{"key":"2026070711243007500_bibr57-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"701693","DOI":"10.1155\/2013\/701693","article-title":"Evaluation of stability of rotating hinge knee prostheses: a biomechanical study","volume":"2013","author":"Friesenbichler","year":"2013","journal-title":"ISRN Orthop"},{"key":"2026070711243007500_bibr58-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"e335","DOI":"10.3928\/01477447-20120222-20","article-title":"In vivo testing of knee stability after rotating-hinge total knee arthroplasty: a comparison of 2 knee systems","volume":"35","author":"Friesenbichler","year":"2012","journal-title":"Orthopedics"},{"key":"2026070711243007500_bibr59-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.arth.2012.05.008","article-title":"Comparison of mechanical and nonmechanical failure rates associated with rotating hinged total knee arthroplasty in nontumor patients","volume":"28","author":"Smith","year":"2013","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr60-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1016\/j.arth.2006.04.018","article-title":"Rotating-hinge total knee arthroplasty in a patient with genu recurvatum after osteomyelitis of the distal femur","volume":"22","author":"Nishitani","year":"2007","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr61-2058-5241.4.180056","first-page":"349","article-title":"The clinical and radiological outcome of the rotating hinged knee prostheses in the long-term","volume":"86","author":"Rinta-Kiikka","year":"1997","journal-title":"Ann Chir Gynaecol"},{"key":"2026070711243007500_bibr62-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"1204","DOI":"10.1016\/j.arth.2007.10.016","article-title":"Is there a place for rotating-hinge arthroplasty in knee revision surgery for aseptic loosening?","volume":"23","author":"Joshi","year":"2008","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr63-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1007\/s11999-009-1226-7","article-title":"Hinged total knee arthroplasty in the presence of ligamentous deficiency","volume":"468","author":"Hern\u00e1ndez-Vaquero","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"2026070711243007500_bibr64-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.otsr.2012.05.019","article-title":"Removal of infected cemented hinge knee prostheses using extended femoral and tibial osteotomies: six cases","volume":"98","author":"Massin","year":"2012","journal-title":"Orthop Traumatol Surg Res"},{"key":"2026070711243007500_bibr65-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1016\/j.arth.2013.12.013","article-title":"Primary rotating-hinge total knee arthroplasty: good outcomes at mid-term follow-up","volume":"29","author":"Kowalczewski","year":"2014","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr66-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"2173","DOI":"10.1016\/j.arth.2015.06.033","article-title":"Intermediate-term results of 142 single-design, rotating-hinge implants: frequent complications may not preclude salvage of severely affected knees","volume":"30","author":"Farid","year":"2015","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr67-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"324","DOI":"10.2106\/JBJS.16.00307","article-title":"Long-term results after total knee arthroplasty with contemporary rotating-hinge prostheses","volume":"99","author":"Cottino","year":"2017","journal-title":"J Bone Joint Surg [Am]"},{"key":"2026070711243007500_bibr68-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/j.arth.2017.10.009","article-title":"Rotating hinge implants for complex primary and revision total knee arthroplasty","volume":"33","author":"Kearns","year":"2018","journal-title":"J Arthroplasty"},{"key":"2026070711243007500_bibr69-2058-5241.4.180056","doi-asserted-by":"crossref","first-page":"2825","DOI":"10.1007\/s00264-018-3982-z","article-title":"Revision knee arthroplasty with rotating hinge systems in patients with gross ligament instability","volume":"42","author":"Boelch","year":"2018","journal-title":"Int Orthop"}],"container-title":["EFORT Open Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/pdf\/10.1302\/2058-5241.4.180056","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/online.boneandjoint.org.uk\/doi\/full-xml\/10.1302\/2058-5241.4.180056","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article-pdf\/4\/4\/121\/16548\/2058-5241.4.180056.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article-pdf\/4\/4\/121\/16548\/2058-5241.4.180056.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T16:03:14Z","timestamp":1783440194000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article\/4\/4\/121\/2144\/Total-knee-arthroplasty-using-hinge-joints"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,1]]},"references-count":69,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,4,25]]},"published-print":{"date-parts":[[2019,4,1]]}},"URL":"https:\/\/doi.org\/10.1302\/2058-5241.4.180056","relation":{},"ISSN":["2058-5241"],"issn-type":[{"value":"2058-5241","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4,1]]}}}