{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T12:12:51Z","timestamp":1793707971334,"version":"4.6.1"},"reference-count":40,"publisher":"Oxford University Press (OUP)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,3,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Rapid onsite evaluation (ROSE) has the potential to improve the adequacy rates of fine-needle aspiration (FNA) cytology. Studies have obtained variable results on the influence of ROSE. We conducted a systematic review and meta-analysis of studies on the influence of ROSE on FNA adequacy. We synthesized evidence across all anatomic locations. We only included studies that contained a control arm and compared cohorts with ROSE against cohorts without ROSE at a single location. We screened 2,179 studies and identified 25 studies that met our inclusion criteria. On average, ROSE improves the adequacy rate by 12%, but there was considerable variability across studies. The adequacy rate with ROSE depends on the non-ROSE adequacy rate. Sixty-five percent of the variability in the adequacy rate with ROSE was found to occur because of differences in the adequacy rate without ROSE. Studies with high non-ROSE adequacy rates showed low improvement after ROSE was implemented. Studies must account for the effect of the non-ROSE adequacy rate to determine the effect of ROSE on FNA adequacy rates.<\/jats:p>","DOI":"10.1309\/ajcpegzmjkc42vup","type":"journal-article","created":{"date-parts":[[2013,2,21]],"date-time":"2013-02-21T06:44:58Z","timestamp":1361429098000},"page":"300-308","source":"Crossref","is-referenced-by-count":142,"title":["The Influence of Rapid Onsite Evaluation on the Adequacy Rate of Fine-Needle Aspiration Cytology"],"prefix":"10.1093","volume":"139","author":[{"given":"Robert L.","family":"Schmidt","sequence":"first","affiliation":[{"name":"Department of Pathology, University of Utah School of Medicine and ARUP Laboratories, Salt Lake City, UT"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin L.","family":"Witt","sequence":"additional","affiliation":[{"name":"Department of Pathology, University of Utah School of Medicine and ARUP Laboratories, Salt Lake City, UT"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leslie E.","family":"Lopez-Calderon","sequence":"additional","affiliation":[{"name":"Department of Pathology, University of Utah School of Medicine and ARUP Laboratories, Salt Lake City, UT"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lester J.","family":"Layfield","sequence":"additional","affiliation":[{"name":"Department of Pathology, University of Utah School of Medicine and ARUP Laboratories, Salt Lake City, UT"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2013,3,1]]},"reference":[{"key":"2023012006254482700_b1-0030300","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1309\/AJCPQX1KBJ2PZJFK","article-title":"Methods specification for diagnostic test accuracy studies in fineneedle aspiration cytology: a survey of reporting practice","volume":"137","author":"Schmidt","year":"2012","journal-title":"Am J Clin Pathol"},{"key":"2023012006254482700_b2-0030300","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.gie.2008.10.008","article-title":"EUS-guided FNA of solid pancreatic masses: high yield of 2 passes with combined histologic-cytologic analysis","volume":"70","author":"Moller","year":"2009","journal-title":"Gastrointest Endosc"},{"key":"2023012006254482700_b3-0030300","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1016\/j.gie.2010.01.029","article-title":"An evaluation of risk factors for inadequate cytology in EUS-guided FNA of pancreatic tumors and lymph nodes","volume":"71","author":"Cleveland","year":"2010","journal-title":"Gastrointest Endosc"},{"key":"2023012006254482700_b4-0030300","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/S0016-5107(03)02863-3","article-title":"Optimal number of EUS-guided fine needle passes needed to obtain a correct diagnosis","volume":"59","author":"LeBlanc","year":"2004","journal-title":"Gastrointest Endosc"},{"key":"2023012006254482700_b5-0030300","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1111\/j.1440-1746.2008.05636.x","article-title":"Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses","volume":"24","author":"Sakamoto","year":"2009","journal-title":"J Gastroenterol Hepatol"},{"issue":"suppl 2","key":"2023012006254482700_b6-0030300","doi-asserted-by":"crossref","first-page":"E87","DOI":"10.1055\/s-0028-1103444","article-title":"Endoscopic ultrasound-guided fine-needle aspiration using 22- and 25-gauge needles alternately","volume":"41","author":"Iqbal","year":"2009","journal-title":"Endoscopy"},{"key":"2023012006254482700_b7-0030300","doi-asserted-by":"crossref","first-page":"546390","DOI":"10.1155\/2009\/546390","article-title":"A prospective comparison of EUS-guided FNA using 25-gauge and 22-gauge needles","volume":"2009","author":"Imazu","year":"2009","journal-title":"Gastroenterol Res Pract"},{"key":"2023012006254482700_b8-0030300","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1097\/MPA.0b013e3181c5c597","article-title":"Endoscopic ultrasoundguided fine needle aspiration of pancreatic masses in a veteran population: comparison of results with 22- and 25-gauge needles","volume":"39","author":"Siddiqui","year":"2010","journal-title":"Pancreas"},{"key":"2023012006254482700_b9-0030300","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1002\/cncr.9040","article-title":"Diagnostic accuracy of fine-needle aspiration biopsy is determined by physician training in sampling technique","volume":"93","author":"Ljung","year":"2001","journal-title":"Cancer"},{"key":"2023012006254482700_b10-0030300","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1111\/j.1365-2265.2011.04011.x","article-title":"Factors affecting inadequate sampling of ultrasound-guided fine-needle aspiration biopsy of thyroid nodules","volume":"74","author":"Choi","year":"2011","journal-title":"Clin Endocrinol"},{"key":"2023012006254482700_b11-0030300","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1111\/j.1572-0241.2003.07472.x","article-title":"Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration","volume":"98","author":"Klapman","year":"2003","journal-title":"Am J Gastroenterol"},{"key":"2023012006254482700_b12-0030300","doi-asserted-by":"crossref","first-page":"1705","DOI":"10.1038\/ajg.2011.119","article-title":"Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses","volume":"106","author":"Iglesias-Garcia","year":"2011","journal-title":"Am J Gastroenterol"},{"key":"2023012006254482700_b13-0030300","volume-title":"Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy, Version 1.0.0","author":"Deeks","year":"2009"},{"key":"2023012006254482700_b14-0030300","doi-asserted-by":"crossref","first-page":"889","DOI":"10.7326\/0003-4819-149-12-200812160-00008","article-title":"Systematic reviews of diagnostic test accuracy","volume":"149","author":"Leeflang","year":"2008","journal-title":"Ann Int Med"},{"key":"2023012006254482700_b15-0030300","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1002\/sim.1186","article-title":"Quantifying heterogeneity in a meta-analysis","volume":"21","author":"Higgins","year":"2002","journal-title":"Stat Med"},{"key":"2023012006254482700_b16-0030300","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1159\/000324997","article-title":"Efficacy of on-site specimen adequacy evaluation of image-guided fine and core needle biopsies","volume":"54","author":"Azabdaftari","year":"2010","journal-title":"Acta Cytol"},{"key":"2023012006254482700_b17-0030300","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1378\/chest.98.1.59","article-title":"Rapid on-site evaluation of transbronchial aspirates","volume":"98","author":"Davenport","year":"1990","journal-title":"Chest"},{"key":"2023012006254482700_b18-0030300","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1378\/chest.117.4.1186","article-title":"Utility of on-site cytopathology assessment for bronchoscopic evaluation of lung masses and adenopathy","volume":"117","author":"Diette","year":"2000","journal-title":"Chest"},{"key":"2023012006254482700_b19-0030300","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1046\/j.1365-2303.2000.00216.x","article-title":"Improved fine needle aspiration (FNA) cytology results with a near patient diagnosis service for breast lesions","volume":"11","author":"Dray","year":"2000","journal-title":"Cytopathology"},{"key":"2023012006254482700_b20-0030300","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1002\/cncr.21715","article-title":"The value of onsite adequacy assessment of thyroid fine-needle aspirations is a function of operator experience","volume":"108","author":"Ghofrani","year":"2006","journal-title":"Cancer"},{"key":"2023012006254482700_b21-0030300","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1159\/000326710","article-title":"Improved breast cytology results with near patient FNA diagnosis","volume":"46","author":"Hamill","year":"2002","journal-title":"Acta Cytol"},{"key":"2023012006254482700_b22-0030300","first-page":"631","article-title":"Endoscopic ultrasound in the diagnosis and staging of pancreatic cancer","volume":"101","author":"Iglesias","year":"2009","journal-title":"Rev Esp Enferm Dig"},{"key":"2023012006254482700_b23-0030300","doi-asserted-by":"crossref","first-page":"AB332","DOI":"10.1016\/j.gie.2009.03.958","article-title":"Onsite cytopathology improves yield in endobronchial ultrasound (EBUS) guided fine needle aspiration of mediastinal lymph nodes: a prospective blinded study","volume":"69","author":"Jamil","year":"2009","journal-title":"Gastrointest Endosc"},{"key":"2023012006254482700_b24-0030300","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1002\/dc.20762","article-title":"The clinical and diagnostic impact of using standard criteria of adequacy assessment and diagnostic terminology on thyroid nodule fine needle aspiration","volume":"36","author":"Jing","year":"2008","journal-title":"Diagn Cytopathol"},{"key":"2023012006254482700_b25-0030300","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1111\/j.1440-1843.2004.00607.x","article-title":"Computed tomographyguided transthoracic fine-needle aspiration in diagnosis of lung cancer: a comparison of single-pass needle and multiplepass coaxial needle systems and the value of immediate cytological assessment","volume":"9","author":"Kucuk","year":"2004","journal-title":"Respirology"},{"key":"2023012006254482700_b26-0030300","first-page":"657","article-title":"On-site adequacy assessments for image-directed fine needle aspirations: a study of 341 cases","volume":"59","author":"Lachman","year":"1995","journal-title":"Conn Med"},{"key":"2023012006254482700_b27-0030300","doi-asserted-by":"crossref","first-page":"1979","DOI":"10.1002\/lary.21061","article-title":"Ultrasound-guided needle aspiration: impact of immediate cytologic review","volume":"120","author":"Moberly","year":"2010","journal-title":"Laryngoscope"},{"key":"2023012006254482700_b28-0030300","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1148\/radiol.2222010201","article-title":"US-guided fineneedle aspiration biopsy of thyroid nodules: adequacy of cytologic material and procedure time with and without immediate cytologic analysis","volume":"222","author":"O'Malley","year":"2002","journal-title":"Radiology"},{"key":"2023012006254482700_b29-0030300","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1097\/00004424-199708000-00004","article-title":"The value of immediate cytologic evaluation for needle aspiration lung biopsy","volume":"32","author":"Padhani","year":"1997","journal-title":"Invest Radiol"},{"key":"2023012006254482700_b30-0030300","first-page":"S41","article-title":"Effectiveness of ultrasoundguided thyroid FNA with on-site pathology","volume":"19","author":"Parikh","year":"2009","journal-title":"Thyroid"},{"key":"2023012006254482700_b31-0030300","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1309\/NJQ1L7KA10UKV93Q","article-title":"Effectiveness of Toyota process redesign in reducing thyroid gland fine-needle aspiration error","volume":"126","author":"Raab","year":"2006","journal-title":"Am J Clin Pathol"},{"key":"2023012006254482700_b32-0030300","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1089\/thy.2006.16.55","article-title":"The impact of assessing specimen adequacy and number of needle passes for fine-needle aspiration biopsy of thyroid nodules","volume":"16","author":"Redman","year":"2006","journal-title":"Thyroid"},{"key":"2023012006254482700_b33-0030300","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1159\/000333985","article-title":"Positive economic and diagnostic accuracy impacts of on-site evaluation of fine needle aspiration biopsies by pathologists","volume":"40","author":"Saleh","year":"1996","journal-title":"Acta Cytol"},{"key":"2023012006254482700_b34-0030300","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1378\/chest.112.2.423","article-title":"CT-guided fine-needle aspiration cytology of solitary pulmonary nodules: a prospective, randomized study of immediate cytologic evaluation","volume":"112","author":"Santambrogio","year":"1997","journal-title":"Chest"},{"key":"2023012006254482700_b35-0030300","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1378\/chest.10-1521","article-title":"Rapid on-site evaluation of transbronchial aspirates in the diagnosis of hilar and mediastinal adenopathy: a randomized trial","volume":"139","author":"Trisolini","year":"2011","journal-title":"Chest"},{"key":"2023012006254482700_b36-0030300","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1016\/j.jvir.2011.03.019","article-title":"CT-guided biopsy of bone and soft-tissue lesions: role of on-site immediate cytologic evaluation","volume":"22","author":"Virayavanich","year":"2011","journal-title":"J Vasc Interv Radiol"},{"key":"2023012006254482700_b37-0030300","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1097\/LBR.0b013e31821707ee","article-title":"A randomized prospective trial of the utility of rapid on-site evaluation of transbronchial needle aspirate specimens","volume":"18","author":"Yarmus","year":"2011","journal-title":"J Bronchol Interv Pulmonol"},{"key":"2023012006254482700_b38-0030300","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1002\/dc.20552","article-title":"How important is on-site adequacy assessment for thyroid FNA? An evaluation of 883 cases","volume":"35","author":"Zhu","year":"2007","journal-title":"Diagn Cytopathol"},{"key":"2023012006254482700_b39-0030300","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1002\/dc.20846","article-title":"Rapid cell blocks improve accuracy of breast FNAs beyond that provided by conventional cell blocks regardless of immediate adequacy evaluation","volume":"36","author":"Akalin","year":"2008","journal-title":"Diagn Cytopathol"},{"key":"2023012006254482700_b40-0030300","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1288\/00005537-199212000-00002","article-title":"Utility of immediate on-site cytopathological procurement and evaluation in fine needle aspiration biopsy of head and neck masses","volume":"102","author":"Eisele","year":"1992","journal-title":"Laryngoscope"}],"container-title":["American Journal of Clinical Pathology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/ajcp\/article-pdf\/139\/3\/300\/48794178\/ajcp_139_3_300.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/ajcp\/article-pdf\/139\/3\/300\/48794178\/ajcp_139_3_300.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,20]],"date-time":"2023-01-20T06:28:09Z","timestamp":1674196089000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/ajcp\/article\/139\/3\/300\/1765997"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,3,1]]},"references-count":40,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2013,3,1]]},"published-print":{"date-parts":[[2013,3,1]]}},"URL":"https:\/\/doi.org\/10.1309\/ajcpegzmjkc42vup","relation":{},"ISSN":["1943-7722","0002-9173"],"issn-type":[{"value":"1943-7722","type":"electronic"},{"value":"0002-9173","type":"print"}],"subject":[],"published-other":{"date-parts":[[2013,3,1]]},"published":{"date-parts":[[2013,3,1]]}}}