{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,6]],"date-time":"2024-08-06T12:05:55Z","timestamp":1722945955365},"reference-count":0,"publisher":"Indian Orthopaedic Research Group","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["jocr"],"published-print":{"date-parts":[[2024]]},"abstract":"<jats:p>Introduction: The aim of this study was to investigate whether surgery with a 10 mm approach for volar locking plate fixation provides equivalent early post-operative outcomes to conventional incision surgery for distal radius fractures.  Materials and Methods: The subjects were divided into a conventional incision group (mean age: 59.1 years, 8 males and 23 females) and a 10 mm approach group (mean age: 59.9 years of age, 6 males and 20 females). The wrist range of motion; grip strength; visual analog scale (VAS); quick disabilities of the arm, shoulder, and hand (Q-DASH) score; and modified Mayo score were assessed at 3 months after surgery. In addition, radial inclination, ulnar variance, and volar tilt were evaluated on post-operative radiography.  Results: There was no significant difference between the groups in the wrist range of motion, grip strength, VAS, Q-DASH score, modified Mayo wrist score, and three parameters of post-operative radiography. All patients in both groups had no complications during the perioperative period.  Conclusion: We found that a 10 mm approach obtained early post-operative outcomes and alignment comparable to conventional incision surgery for patients with dorsal displaced distal radius fractures.  Keywords: Distal radius fractures, volar locking plates, conventional incision, 10 mm approach, minimally invasive plate osteosynthesis.<\/jats:p>","DOI":"10.13107\/jocr.2024.v14.i06.4546","type":"journal-article","created":{"date-parts":[[2024,6,16]],"date-time":"2024-06-16T14:54:05Z","timestamp":1718549645000},"page":"186-190","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of Conventional Incision and 10 mm Approach for Volar Locking Plates in Dorsal Displaced Distal Radius Fractures"],"prefix":"10.13107","volume":"14","author":[{"name":"Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo, Japan,","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ren","family":"Kunishige","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiyohito","family":"Naito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo, Japan, Department of Medicine for Orthopedics and Motor Organ, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Obata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo, Japan,","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"So","family":"Kawakita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo, Japan, Department of Medicine for Orthopedics and Motor Organ, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takamaru","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo, Japan, Department of Medicine for Orthopedics and Motor Organ, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muneaki","family":"Ishijima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Department of Orthopedics, Juntendo University Faculty of Medicine, Bunkyo-ku, Tokyo, Japan, Department of Medicine for Orthopedics and Motor Organ, Juntendo University Graduate School of Medicine, Bunkyo-ku, Tokyo, Japan.","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5271","published-online":{"date-parts":[[2024]]},"container-title":["Journal of Orthopaedic Case Reports"],"original-title":[],"deposited":{"date-parts":[[2024,6,16]],"date-time":"2024-06-16T14:54:14Z","timestamp":1718549654000},"score":1,"resource":{"primary":{"URL":"https:\/\/jocr.co.in\/wp\/2024\/06\/10\/comparison-of-conventional-incision-and-10-mm-approach-for-volar-locking-plates-in-dorsal-displaced-distal-radius-fractures\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":0,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024]]},"published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.13107\/jocr.2024.v14.i06.4546","relation":{},"ISSN":["2321-3817"],"issn-type":[{"type":"electronic","value":"2321-3817"}],"subject":[],"published":{"date-parts":[[2024]]}}}