{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T23:16:04Z","timestamp":1784243764430,"version":"3.55.0"},"reference-count":0,"publisher":"Indian Orthopaedic Research Group","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Jocr"],"published-print":{"date-parts":[[2024]]},"abstract":"<jats:p>Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra-articular distal radius fracture. Combined dorsal spanning plate and volar plating is a rare procedure reserved typically for comminuted fractures of the distal radius. This case highlights the first reported incidence in which a dorsal spanning plate of a distal radius fracture resulted in the volar displacement of the fragments, requiring subsequent volar plating. In the end, the outcome was favorable, as the follow-up imaging displayed good bone healing and union with minimal complications.  Case Report: A 52-year-old male presented to the ED at our institution following a traumatic fall onto his left upper extremity. Radiographic imaging revealed fractures at the midshaft of the humerus as well as a very distal three-part intra-articular radius fracture. Due to the nature of the patient\u2019s distal radius fracture, initial fixation with a dorsal spanning plate was planned. However, follow-up imaging 3 weeks postoperatively revealed volar displacement of his fracture, so the patient underwent open reduction internal fixation with a volar distal radius plate. Follow-up over the next few months displayed a union of the fracture fragments and the dorsal spanning plate was removed 4 months postoperatively with imaging showing no complications.  Conclusion: We present this case to highlight the complication of volar displacement that may follow initial dorsal spanning plate fixation of a three-part intra-articular distal radius fracture that can be resolved with the addition of a volar plate, as well as possible indications for combined dorsal spanning plate and volar plate fixation of complex distal radius fractures at the time of initial fixation.  Keywords: Distal radius, volar plate, spanning plate, fracture, comminution, intra-articular fracture.<\/jats:p>","DOI":"10.13107\/jocr.2024.v14.i11.4944","type":"journal-article","created":{"date-parts":[[2024,11,3]],"date-time":"2024-11-03T12:03:36Z","timestamp":1730635416000},"page":"143-147","source":"Crossref","is-referenced-by-count":1,"title":["Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report"],"prefix":"10.13107","volume":"14","author":[{"name":"Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, 43614.","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anderson","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian","family":"Rao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, 43614.","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dave","family":"Yatsonsky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, 43614.","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyle","family":"Behrens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, 43614.","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Phillip J.","family":"Stokey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, 43614.","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nabil","family":"Ebraheim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"Department of Orthopaedic Surgery, University of Toledo Medical Center, Toledo, OH, 43614.","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"5271","published-online":{"date-parts":[[2024]]},"container-title":["Journal of Orthopaedic Case Reports"],"original-title":[],"deposited":{"date-parts":[[2024,11,3]],"date-time":"2024-11-03T12:03:38Z","timestamp":1730635418000},"score":1,"resource":{"primary":{"URL":"https:\/\/jocr.co.in\/wp\/2024\/11\/01\/fixation-of-3-part-intra-articular-distal-radius-fracture-with-combined-volar-plate-and-dorsal-spanning-plate-a-case-report-2\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":0,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2024]]},"published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.13107\/jocr.2024.v14.i11.4944","relation":{},"ISSN":["2321-3817"],"issn-type":[{"value":"2321-3817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024]]}}}