{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T04:39:21Z","timestamp":1778042361918,"version":"3.51.4"},"reference-count":0,"publisher":"Indian Orthopaedic Research Group","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Jocr"],"published-print":{"date-parts":[[2025]]},"abstract":"<jats:p>Introduction: Distal femur fractures present significant surgical challenges due to their complex anatomy and limited soft tissue coverage. Minimally invasive plate osteosynthesis (MIPO) has emerged as a promising alternative to traditional open techniques, aiming to reduce soft-tissue damage while maintaining stable fixation, particularly when used with locking plates.\n\nMaterials and Methods: This retrospective study analyzed 40 consecutive patients with distal femur fractures treated with MIPO and locking plates.\n\nResults: The results showed a high union rate of 92.5%, with fractures healing within 16\u201324 weeks (mean: 19.2 weeks). Complications occurred in 12.5% of cases, including three cases of malalignment, one case of screw breakage, and one infection. Functional outcomes were positive, with 85% of patients achieving excellent or good results based on the Knee Society Score, indicating satisfactory postoperative mobility and joint function.\n\nConclusion: MIPO using locking plates is a reliable and effective treatment for distal femur fractures, offering high union rates, manageable complication rates, and favorable functional outcomes while minimizing soft-tissue disruption.\n\nKeywords: Femoral shaft fractures, minimally invasive plate osteosynthesis, screw configuration, union rate.<\/jats:p>","DOI":"10.13107\/jocr.2025.v15.i01.5198","type":"journal-article","created":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T08:31:28Z","timestamp":1736411488000},"page":"273-278","source":"Crossref","is-referenced-by-count":3,"title":["Minimally Invasive Plate Osteosynthesis Using Locking Plates for Distal Femur Fractures: A Retrospective Analysis of 40 Cases"],"prefix":"10.13107","volume":"15","author":[{"name":"Department of Orthopedics, Sree Balaji Medical College and Hospital, BIHER, Chromepet, Chennai, Tamil Nadu, India.","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M T","family":"Ganesh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haemanath","family":"Pandian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Department of Orthopedics, Sree Balaji Medical College and Hospital, BIHER, Chromepet, Chennai, Tamil Nadu, India.","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"5271","published-online":{"date-parts":[[2025]]},"container-title":["Journal of Orthopaedic Case Reports"],"original-title":[],"deposited":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T08:31:30Z","timestamp":1736411490000},"score":1,"resource":{"primary":{"URL":"https:\/\/jocr.co.in\/wp\/2025\/01\/01\/minimally-invasive-plate-osteosynthesis-using-locking-plates-for-distal-femur-fractures-a-retrospective-analysis-of-40-cases\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":0,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025]]},"published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.13107\/jocr.2025.v15.i01.5198","relation":{},"ISSN":["2321-3817"],"issn-type":[{"value":"2321-3817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025]]}}}