{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T20:21:24Z","timestamp":1793218884825,"version":"4.5.0"},"reference-count":27,"publisher":"Oxford University Press (OUP)","issue":"7","license":[{"start":{"date-parts":[[1999,7,1]],"date-time":"1999-07-01T00:00:00Z","timestamp":930787200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1999,7,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The appearance of cancellous bone architecture is different for various skeletal sites and various disease states. During aging and disease, plates are perforated and connecting rods are dissolved. There is a continuous shift from one structural type to the other. So traditional histomorphometric procedures, which are based on a fixed model type, will lead to questionable results. The introduction of three-dimensional (3D) measuring techniques in bone research makes it possible to capture the actual architecture of cancellous bone without assumptions of the structure type. This requires, however, new methods that make direct use of the 3D information. Within the framework of a BIOMED I project of the European Union, we analyzed a total of 260 human bone biopsies taken from five different skeletal sites (femoral head, vertebral bodies L2 and L4, iliac crest, and calcaneus) from 52 donors. The samples were measured three-dimensionally with a microcomputed tomography scanner and subsequently evaluated with both traditional indirect histomorphometric methods and newly developed direct ones. The results show significant differences between the methods and in their relation to the bone volume fraction. Based on the direct 3D analysis of human bone biopsies, it appears that samples with a lower bone mass are primarily characterized by a smaller plate-to-rod ratio, and to a lesser extent by thinner trabecular elements.<\/jats:p>","DOI":"10.1359\/jbmr.1999.14.7.1167","type":"journal-article","created":{"date-parts":[[2006,4,27]],"date-time":"2006-04-27T01:46:10Z","timestamp":1146102370000},"page":"1167-1174","source":"Crossref","is-referenced-by-count":1136,"title":["Direct Three-Dimensional Morphometric Analysis of Human Cancellous Bone: Microstructural Data from Spine, Femur, Iliac Crest, and Calcaneus"],"prefix":"10.1093","volume":"14","author":[{"given":"Tor","family":"Hildebrand","sequence":"first","affiliation":[{"name":"Institute for Biomedical Engineering, University of Z\u00fcrich and Swiss Federal Institute of Technology (ETH), Z\u00fcrich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andres","family":"Laib","sequence":"additional","affiliation":[{"name":"Institute for Biomedical Engineering, University of Z\u00fcrich and Swiss Federal Institute of Technology (ETH), Z\u00fcrich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralph","family":"M\u00fcller","sequence":"additional","affiliation":[{"name":"Orthopedic Biomechanics Laboratory, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, Massachusetts, U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Dequeker","sequence":"additional","affiliation":[{"name":"Arthritis and Metabolic Bone Disease Research Unit, K.U. Leuven, University Hospital, Pellenberg, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"R\u00fcegsegger","sequence":"additional","affiliation":[{"name":"Institute for Biomedical Engineering, University of Z\u00fcrich and Swiss Federal Institute of Technology (ETH), Z\u00fcrich, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2009,12,2]]},"reference":[{"key":"2024020713363371600_bib1","first-page":"74","article-title":"The dependence of elastic constants of cancellous bone upon structural density and fabric","volume":"13","author":"Turner","year":"1988","journal-title":"Trans Orthopaed Res Soc"},{"key":"2024020713363371600_bib2","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/0021-9290(88)90008-5","article-title":"On the dependence of elasticity and strength of cancellous bone on apparent density","volume":"22","author":"Rice","year":"1988","journal-title":"J Biomech"},{"key":"2024020713363371600_bib3","volume-title":"Stereological Methods, Vol. 2: Theoretical Foundations","author":"Weibel","year":"1980"},{"key":"2024020713363371600_bib4","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1111\/j.1365-2818.1974.tb03878.x","article-title":"The quantitative morphology of anisotropic trabecular bone","volume":"101","author":"Whitehouse","year":"1974","journal-title":"J Microsc"},{"key":"2024020713363371600_bib5","first-page":"1396","article-title":"Relationships between surface, volume, and thickness of iliac trabecular bone in aging and in osteoporosis","volume":"72","author":"Parfitt","year":"1983","journal-title":"Calcif Tissue Int"},{"key":"2024020713363371600_bib6","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1111\/j.1365-2818.1990.tb03038.x","article-title":"A direct method for fast three-dimensional serial reconstruction","volume":"159","author":"Odgaard","year":"1990","journal-title":"J Microsc"},{"key":"2024020713363371600_bib7","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1002\/jbmr.5650040103","article-title":"The direct examination of three-dimensional bone architecture in vitro by computed tomography","volume":"4","author":"Feldkamp","year":"1989","journal-title":"J Bone Miner Res"},{"key":"2024020713363371600_bib8","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/S0169-6009(08)80205-X","article-title":"3D computed X-ray tomography of human cancellous bone at 8 \u03bcm spatial and 10\u20134 energy resolution","volume":"25","author":"Bonse","year":"1994","journal-title":"Bone Miner"},{"key":"2024020713363371600_bib9","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1007\/BF02509542","article-title":"A microtomographic system for the non-destructive evaluation of bone architecture","volume":"58","author":"R\u00fcegsegger","year":"1996","journal-title":"Calcif Tissue Int"},{"key":"2024020713363371600_bib10","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/S8756-3282(98)00068-4","article-title":"Morphometric analysis of human bone biopsies: A quantitative structural comparison of hisological sections and micro-computed tomography","volume":"23","author":"M\u00fcller","year":"1998","journal-title":"Bone"},{"key":"2024020713363371600_bib11","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1111\/j.1365-2818.1994.tb03447.x","article-title":"Volume and surface area of viable chondrocytes in situ using geometric modelling of serial confocal sections","volume":"173","author":"Guilak","year":"1994","journal-title":"J Microsc"},{"key":"2024020713363371600_bib12","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1046\/j.1365-2818.1997.1340694.x","article-title":"A new method for the model independent assessment of thickness in three-dimensional images","volume":"185","author":"Hildebrand","year":"1997","journal-title":"J Microsc"},{"key":"2024020713363371600_bib13","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/8756-3282(93)90245-6","article-title":"Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions","volume":"14","author":"Odgaard","year":"1993","journal-title":"Bone"},{"key":"2024020713363371600_bib14","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1080\/01495739708936692","article-title":"Quantification of bone microarchitecture with the structure model index","volume":"1","author":"Hildebrand","year":"1997","journal-title":"Comp Meth Biomech Biomed Eng"},{"key":"2024020713363371600_bib15","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/S8756-3282(97)00007-0","article-title":"Three-dimensional methods for quantification of cancellous bone architecture","volume":"20","author":"Odgaard","year":"1997","journal-title":"Bone"},{"key":"2024020713363371600_bib16","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1677\/joe.0.1550411","article-title":"Variations in trabecular bone composition with anatomical site and age: Potential implication for bone quality assessment","volume":"155","author":"Aerssens","year":"1997","journal-title":"J Endocrinol"},{"issue":"Suppl 1","key":"2024020713363371600_bib17","first-page":"7","article-title":"Assessment of quality of bone in osteoporosis BIOMED I: Fundamental study of relevant bone","volume":"13","author":"Dequeker","year":"1994","journal-title":"Clin Rheumatol"},{"key":"2024020713363371600_bib18","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1145\/37402.37422","article-title":"Marching Cubes: A high resolution 3D surface construction algorithm","volume":"21","author":"Lorensen","year":"1987","journal-title":"Computer Graphics"},{"key":"2024020713363371600_bib19","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1088\/0031-9155\/39\/1\/009","article-title":"Non-invasive bone biopsy: A new method to analyse and display the three-dimensional structure of trabecular bone","volume":"39","author":"M\u00fcller","year":"1994","journal-title":"Phys Med Biol"},{"key":"2024020713363371600_bib20","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/0021-9290(94)90014-0","article-title":"The relationship between the structural and orthogonal compressive properties of trabecular bone","volume":"27","author":"Goulet","year":"1994","journal-title":"J Biomech"},{"key":"2024020713363371600_bib21","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1359\/jbmr.1997.12.6.942","article-title":"Method-based differences in the automaded analysis of three-dimensional morphology of trabecular bone","volume":"12","author":"Simmons","year":"1997","journal-title":"J Bone Miner Res"},{"key":"2024020713363371600_bib22","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1002\/jbmr.5650020617","article-title":"Bone histomorphometry: Standardization of nomenclature, symbols and units. Report of the ASBMR histomorphometry nomenclature committee","volume":"21","author":"Parfitt","year":"1987","journal-title":"J Bone Miner Res"},{"key":"2024020713363371600_bib23","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1007\/BF00540446","article-title":"Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor","volume":"19","author":"Harrigan","year":"1984","journal-title":"J Mater Sci"},{"key":"2024020713363371600_bib24","first-page":"197","article-title":"Age-related changes in cancellous bone structure, a two-dimensional study in the transiliac iliac crest biopsy sites","volume":"4","author":"Birkenh\u00e4ger-Frenkel","year":"1988","journal-title":"Bone Miner"},{"key":"2024020713363371600_bib25","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/0021-9290(95)80008-5","article-title":"A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models","volume":"28","author":"Van Rietbergen","year":"1995","journal-title":"J Biomech"},{"key":"2024020713363371600_bib26","first-page":"97","volume-title":"Bone Research Biomechanics","author":"Ulrich","year":"1997"},{"key":"2024020713363371600_bib27","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1016\/S8756-3282(97)00205-6","article-title":"Ridge number density: A new parameter for in vivo bone structure analysis","volume":"21","author":"Laib","year":"1997","journal-title":"Bone"}],"container-title":["Journal of Bone and Mineral Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1359%2Fjbmr.1999.14.7.1167","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1359\/jbmr.1999.14.7.1167","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1359\/jbmr.1999.14.7.1167","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/jbmr\/article-pdf\/14\/7\/1167\/56601617\/jbmr5650140713.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbmr\/article-pdf\/14\/7\/1167\/56601617\/jbmr5650140713.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T14:58:30Z","timestamp":1710341910000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbmr\/article\/14\/7\/1167-1174\/7514786"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,7,1]]},"references-count":27,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2009,12,2]]},"published-print":{"date-parts":[[1999,7,1]]}},"URL":"https:\/\/doi.org\/10.1359\/jbmr.1999.14.7.1167","relation":{},"ISSN":["0884-0431","1523-4681"],"issn-type":[{"value":"0884-0431","type":"print"},{"value":"1523-4681","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[1999,7,1]]},"published":{"date-parts":[[1999,7,1]]}}}