{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T13:30:20Z","timestamp":1790861420286,"version":"4.1.0"},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"12","license":[{"start":{"date-parts":[[2000,12,1]],"date-time":"2000-12-01T00:00:00Z","timestamp":975628800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2000,12,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This study investigated the ability of quantitative ultrasound (QUS) to detect reductions in the elastic modulus of cancellous bone caused by mechanical damage. Ultrasonic velocity and attenuation were measured using an in-house parametric imaging system in 46 cancellous bone cores from the human calcaneus. Each core was subjected to a mechanical testing regime to (a) determine the predamage elastic modulus, (b) induce damage by applying specified strains in excess of the yield strain, and (c) measure the postdamage elastic modulus. The specimens were divided into four groups: a control group subjected to a nominally nondestructive 0.7% maximum strain (\u03f5m) and three damage groups subjected to increasing strain levels (\u03f5m = 1.5, 3.0, and 4.5%). QUS measurements before and after the mechanical testing showed no significant differences between the control group and damage groups, despite highly significant (p &amp;lt; 0.001) reductions in the elastic modulus of up to 72%. These results indicate that current QUS techniques do not intrinsically reflect the elastic properties of cancellous bone. This is consistent with ultrasonic properties being determined by other factors (apparent density and\/or architecture), which normally are associated strongly with elastic properties, but only when bone is mechanically intact. Clinically, this implies that ultrasound cannot be expected to detect bone fragility in the absence of major changes in bone density and\/or trabecular architecture.<\/jats:p>","DOI":"10.1359\/jbmr.2000.15.12.2467","type":"journal-article","created":{"date-parts":[[2006,4,27]],"date-time":"2006-04-27T02:33:34Z","timestamp":1146105214000},"page":"2467-2472","source":"Crossref","is-referenced-by-count":43,"title":["Quantitative Ultrasound Does Not Reflect Mechanically Induced Damage in Human Cancellous Bone"],"prefix":"10.1093","volume":"15","author":[{"given":"P. H. F.","family":"Nicholson","sequence":"first","affiliation":[{"name":"Orthopedic Biomechanics Laboratory, Department of Orthopedic Surgery, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. L.","family":"Bouxsein","sequence":"additional","affiliation":[{"name":"Orthopedic Biomechanics Laboratory, Department of Orthopedic Surgery, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, U.S.A."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2009,12,2]]},"reference":[{"key":"2024020714081689100_bib1","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1007\/BF01623454","article-title":"The role of ultrasound in the assessment of osteoporosis: A review","volume":"7","author":"Njeh","year":"1997","journal-title":"Osteoporos Int"},{"key":"2024020714081689100_bib2","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/S0140-6736(95)11456-4","article-title":"Ultrasonic heel measurements to predict hip fracture in elderly women: The EPIDOS prospective study","volume":"348","author":"Hans","year":"1996","journal-title":"Lancet"},{"key":"2024020714081689100_bib3","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1359\/jbmr.1997.12.5.839","article-title":"Quantitative ultrasound of the calcaneus reflects the mechanical properties of calcaneal trabecular bone","volume":"12","author":"Bouxsein","year":"1997","journal-title":"J Bone Miner Res"},{"key":"2024020714081689100_bib4","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1007\/BF00296338","article-title":"Ultrasound and densitometry of the calcaneus correlate with failure loads of cadaveric femurs","volume":"56","author":"Bouxsein","year":"1995","journal-title":"Calcif Tissue Int"},{"key":"2024020714081689100_bib5","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/S8756-3282(96)00370-5","article-title":"Assessment of the strength of the proximal femur in vitro: Relationship with ultrasonic measurements of the calcaneus","volume":"20","author":"Nicholson","year":"1997","journal-title":"Bone"},{"key":"2024020714081689100_bib6","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1088\/0967-3334\/19\/2\/006","article-title":"A model for ultrasonic scattering in cancellous bone based on velocity fluctuations in a binary mixture","volume":"19","author":"Strelitzki","year":"1998","journal-title":"Physiol Meas"},{"key":"2024020714081689100_bib7","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/S8756-3282(99)00011-3","article-title":"Biot theory: A review of its application to ultrasound propagation through cancellous bone","volume":"24","author":"Haire","year":"1999","journal-title":"Bone"},{"key":"2024020714081689100_bib8","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/S0301-5629(99)00034-4","article-title":"Ultrasonic propagation in cancellous bone: A new stratified model","volume":"25","author":"Hughes","year":"1999","journal-title":"Ultrasound Med Biol"},{"key":"2024020714081689100_bib9","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1088\/0031-9155\/35\/10\/004","article-title":"Ultrasonic attenuation and velocity in bone","volume":"35","author":"Evans","year":"1990","journal-title":"Phys Med Biol"},{"key":"2024020714081689100_bib10","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/8756-3282(94)00041-7","article-title":"Do ultrasound measurements on the os calcis reflect more the bone microarchitecture than the bone mass? A two dimensional histomorphometric study","volume":"16","author":"Hans","year":"1995","journal-title":"Bone"},{"key":"2024020714081689100_bib11","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/S8756-3282(98)00128-8","article-title":"Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone?","volume":"23","author":"Nicholson","year":"1998","journal-title":"Bone"},{"key":"2024020714081689100_bib12","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/8756-3282(96)00086-5","article-title":"Prediction of mechanical properties of the human calcaneus by broadband ultrasonic attenuation","volume":"18","author":"Langton","year":"1996","journal-title":"Bone"},{"key":"2024020714081689100_bib13","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/1350-4533(95)00064-X","article-title":"Orthogonal relationships between ultrasonic velocity and material properties of bovine cancellous bone","volume":"18","author":"Njeh","year":"1996","journal-title":"Med Eng Phys"},{"key":"2024020714081689100_bib14","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1007\/s002239900565","article-title":"Acute and subacute changes in the ultrasound measurements of the calcaneus following intense exercise","volume":"63","author":"Bennell","year":"1998","journal-title":"Calcif Tissue Int"},{"key":"2024020714081689100_bib15","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1007\/PL00005820","article-title":"The effects of 10 weeks military training on heel ultrasound and bone turnover","volume":"64","author":"Etherington","year":"1999","journal-title":"Calcif Tissue Int"},{"key":"2024020714081689100_bib16","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1007\/BF00296055","article-title":"Broadband ultrasonic attenuation imaging: A new imaging technique of the os calcis","volume":"54","author":"Laugier","year":"1994","journal-title":"Calcif Tissue Int"},{"key":"2024020714081689100_bib17","doi-asserted-by":"crossref","first-page":"2421","DOI":"10.1088\/0031-9155\/41\/11\/013","article-title":"A comparison of time-domain and frequency domain approaches to ultrasonic velocity measurement in trabecular bone","volume":"41","author":"Nicholson","year":"1996","journal-title":"Phys Med Biol"},{"key":"2024020714081689100_bib18","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1088\/0143-0815\/11\/3\/007","article-title":"A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone","volume":"11","author":"Langton","year":"1990","journal-title":"Clin Phys Physiol Meas"},{"key":"2024020714081689100_bib19","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1002\/jor.1100150115","article-title":"Systematic and random errors in compression testing of trabecular bone","volume":"15","author":"Keaveny","year":"1997","journal-title":"J Orthop Res"},{"key":"2024020714081689100_bib20","doi-asserted-by":"crossref","first-page":"1106","DOI":"10.1121\/1.402637","article-title":"Ultrasonic wave propagation in cancellous and cortical bone: Prediction of some experimental results by Biot's theory","volume":"91","author":"Williams","year":"1992","journal-title":"J Acoust Soc Am"},{"key":"2024020714081689100_bib21","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1190\/1.1438217","article-title":"Elastic wave velocities in heterogeneous and porous media","volume":"2","author":"Wyllie","year":"1956","journal-title":"Geophysics"},{"key":"2024020714081689100_bib22","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/0165-2125(84)90033-7","article-title":"Wave propagation in alternating solid and fluid layers","volume":"6","author":"Schoenberg","year":"1984","journal-title":"Wave Motion"},{"key":"2024020714081689100_bib23","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/8756-3282(94)90900-8","article-title":"Failure mechanisms in human vertebral cancellous bone","volume":"15","author":"Fyhrie","year":"1994","journal-title":"Bone"},{"key":"2024020714081689100_bib24","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1002\/jor.1100150522","article-title":"Dependence of trabecular damage on mechanical strain","volume":"15","author":"Wachtel","year":"1997","journal-title":"J Orthop Res"}],"container-title":["Journal of Bone and Mineral Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1359%2Fjbmr.2000.15.12.2467","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/jbmr\/article-pdf\/15\/12\/2467\/56603723\/5650151219.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbmr\/article-pdf\/15\/12\/2467\/56603723\/5650151219.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T14:59:49Z","timestamp":1710341989000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbmr\/article\/15\/12\/2467-2472\/7515617"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,12,1]]},"references-count":24,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2009,12,2]]},"published-print":{"date-parts":[[2000,12,1]]}},"URL":"https:\/\/doi.org\/10.1359\/jbmr.2000.15.12.2467","relation":{},"ISSN":["0884-0431","1523-4681"],"issn-type":[{"value":"0884-0431","type":"print"},{"value":"1523-4681","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2000,12,1]]},"published":{"date-parts":[[2000,12,1]]}}}