{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T06:27:20Z","timestamp":1790490440492,"version":"4.1.0"},"reference-count":23,"publisher":"Oxford University Press (OUP)","issue":"9","license":[{"start":{"date-parts":[[2001,9,1]],"date-time":"2001-09-01T00:00:00Z","timestamp":999302400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2001,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>We evaluated the precision and accuracy of peripheral dual-energy X-ray absorptiometry (DXA) for the measurement of bone mineral density (BMD) and bone mineral content (BMC) in intact and excised femurs and tibias from rats. Thirty-one Sprague-Dawley rats (18F\/13M; 114\u2013360 g) were used in the study. Precision and accuracy were determined in 23 rats and prediction equations were evaluated in an independent sample of 8 animals. Precision was determined by measuring the right hindquarter three times with repositioning between scans. The femur and tibia were then excised, cleaned, and scanned in triplicate, with repositioning. CVs ranged from 0.66 to 2.24%. Accuracy of BMC was determined by comparison to bone ash values. BMC values for the intact and excised femur significantly overestimated bone ash (p &amp;lt; 0.001) by 33% and 5.5%, respectively. BMC for the intact tibia overestimated ash by 37% (p &amp;lt; 0.001), whereas BMC for the excised tibia underestimated ash by 1% (p &amp;lt; 0.05). However, BMC and bone ash were highly related for both bones, whether BMC was measured in the intact animal or after excision (r2 &amp;gt; 0.99). Cross-validation of prediction equations in an independent sample showed that there were no significant differences between predicted ash (based on BMC from DXA) and measured bone ash. These results suggest the peripheral DXA is a useful tool for measuring intact and excised rat leg bones.<\/jats:p>","DOI":"10.1359\/jbmr.2001.16.9.1682","type":"journal-article","created":{"date-parts":[[2006,4,26]],"date-time":"2006-04-26T20:52:32Z","timestamp":1146084752000},"page":"1682-1687","source":"Crossref","is-referenced-by-count":50,"title":["Validation of Peripheral Dual-Energy X-Ray Absorptiometry for the Measurement of Bone Mineral in Intact and Excised Long Bones of Rats"],"prefix":"10.1093","volume":"16","author":[{"given":"Tim R.","family":"Nagy","sequence":"first","affiliation":[{"name":"Department of Nutrition Sciences and the Clinical Nutrition Research Center, University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles W.","family":"Prince","sequence":"additional","affiliation":[{"name":"Department of Nutrition Sciences and the Clinical Nutrition Research Center, University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Nutrition Sciences and the Clinical Nutrition Research Center, University of Alabama at Birmingham, Birmingham, Alabama, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2009,12,2]]},"reference":[{"key":"2024020714122685800_bib1","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/00004424-199601000-00008","article-title":"The use of dual-energy X-ray absorptiometry in animals","volume":"31","author":"Grier","year":"1996","journal-title":"Invest Radiol"},{"key":"2024020714122685800_bib2","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/S0169-6009(08)80081-5","article-title":"Precision and accuracy for rat whole body and femur bone mineral determination with dual X-ray absorptiometry","volume":"22","author":"Hagiwara","year":"1993","journal-title":"Bone Miner"},{"key":"2024020714122685800_bib3","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1139\/y97-157","article-title":"Precision and accuracy of total body bone mass and body composition measurements in the rat using X-ray-based dual photon absorptiometry","volume":"75","author":"Makan","year":"1997","journal-title":"Can J Physiol Pharmacol"},{"key":"2024020714122685800_bib4","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/S0169-6009(08)80162-6","article-title":"Dual-energy X-ray absorptiometry for measuring total bone mineral content in the rat: Study of accuracy and precision","volume":"26","author":"Casez","year":"1994","journal-title":"Bone Miner"},{"key":"2024020714122685800_bib5","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/8756-3282(94)90708-0","article-title":"DXA for bone density measurements in small rats weighing 150-250 grams","volume":"15","author":"Lu","year":"1994","journal-title":"Bone"},{"key":"2024020714122685800_bib6","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/BF01623658","article-title":"Precision and accuracy of in vivo bone mineral measurements in rats using dual-energy X-ray absorptiometry","volume":"5","author":"Rozenberg","year":"1995","journal-title":"Osteoporos Int"},{"key":"2024020714122685800_bib7","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1002\/jbmr.5650090406","article-title":"Precision of measurement by dual-energy X-ray absorptiometry of bone mineral density and content in rat hindlimb in vitro","volume":"9","author":"Siev\u00e4nen","year":"1994","journal-title":"J Bone Miner Res"},{"key":"2024020714122685800_bib8","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1002\/jbmr.5650070310","article-title":"Sequential and precise in vivo measurement of bone mineral density in rats using dual-energy X-ray absorptiometry","volume":"3","author":"Ammann","year":"1992","journal-title":"J Bone Miner Res"},{"key":"2024020714122685800_bib9","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1002\/jbmr.5650080704","article-title":"Dual-energy X-ray absorptiometry of the rat: Accuracy, precision, and measurement of bone loss","volume":"8","author":"Griffin","year":"1993","journal-title":"J Bone Miner Res"},{"key":"2024020714122685800_bib10","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1002\/jbmr.5650090116","article-title":"Accuracy, precision, and utility of spine and whole-skeleton mineral measurements by DXA in rats","volume":"9","author":"Mitlak","year":"1994","journal-title":"J Bone Miner Res"},{"key":"2024020714122685800_bib11","doi-asserted-by":"crossref","first-page":"1613","DOI":"10.1002\/jbmr.5650091015","article-title":"Effects of free mobilization and low- to high-intensity treadmill running on the immobilization-induced bone loss in rats","volume":"9","author":"Kannus","year":"1994","journal-title":"J Bone Miner Res"},{"key":"2024020714122685800_bib12","doi-asserted-by":"crossref","first-page":"1352","DOI":"10.1002\/jbmr.5650100912","article-title":"Treatment with growth hormone and IGF-I in growing rats increases bone mineral content but not bone mineral density","volume":"10","author":"Rosen","year":"1995","journal-title":"J Bone Miner Res"},{"key":"2024020714122685800_bib13","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/BF00298994","article-title":"Differentiating between orchiectomized rats and controls using measurements of trabecular bone density: A comparison among DXA, histomorphometry, and peripheral quantitative computerized tomography","volume":"57","author":"Rosen","year":"1995","journal-title":"Calcif Tissue Int"},{"key":"2024020714122685800_bib14","doi-asserted-by":"crossref","first-page":"1158","DOI":"10.1359\/jbmr.2000.15.6.1158","article-title":"Making rats rise to erect bipedial stance for feeding partially prevented orchidectomy-induced bone loss and added bone to intact rats","volume":"15","author":"Yao","year":"2000","journal-title":"J Bone Miner Res"},{"key":"2024020714122685800_bib15","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1007\/s003359901159","article-title":"Quantitative train loci for bone density in C57BL\/6J and CAST\/EiJ inbred mice","volume":"10","author":"Beamer","year":"1999","journal-title":"Mamm Genome"},{"key":"2024020714122685800_bib16","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1016\/8756-3282(96)00047-6","article-title":"Genetic variability in adult bone density among inbred strains of mice","volume":"18","author":"Beamer","year":"1996","journal-title":"Bone"},{"key":"2024020714122685800_bib17","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1172\/JCI6730","article-title":"Increased cortical bone mineral content but unchanged trabecular bone mineral density in female ER\u00e1\u2212\/\u2212 mice","volume":"104","author":"Windahl","year":"1999","journal-title":"J Clin Invest"},{"key":"2024020714122685800_bib18","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1111\/j.1651-2227.1998.tb01759.x","article-title":"Dual energy X-ray absorptiometry of the hand and wrist\u2014a possible technique to assess skeletal maturation: Methodology and data in normal youths","volume":"87","author":"Braillon","year":"1998","journal-title":"Acta Paediatr"},{"key":"2024020714122685800_bib19","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1259\/bjr.73.865.10721317","article-title":"Comparison of bone mineral density and quantitative ultrasound of the calcaneus: Site-matched correlations and discrimination of axial BMD status","volume":"73","author":"Langton","year":"2000","journal-title":"Br J Radiol"},{"key":"2024020714122685800_bib20","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1038\/oby.2000.47","article-title":"Precision and accuracy of dual-energy X-ray absorptiometry for determining in vivo body composition of mice","volume":"8","author":"Nagy","year":"2000","journal-title":"Obes Res"},{"key":"2024020714122685800_bib21","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1007\/BF01774016","article-title":"Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques","volume":"5","author":"Gl\u00fcer","year":"1995","journal-title":"Osteoporos Int"},{"key":"2024020714122685800_bib22","first-page":"191","author":"Guo","year":"1996"},{"key":"2024020714122685800_bib23","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/BF00425871","article-title":"Subregion analysis of the rat femur: A sensitive indicator of changes in bone density following treatment with thyroid hormone or bisphosphonates","volume":"55","author":"Rosen","year":"1994","journal-title":"Calcif Tissue Int"}],"container-title":["Journal of Bone and Mineral Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1359%2Fjbmr.2001.16.9.1682","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/academic.oup.com\/jbmr\/article-pdf\/16\/9\/1682\/56604148\/5650160914.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/jbmr\/article-pdf\/16\/9\/1682\/56604148\/5650160914.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T15:03:31Z","timestamp":1710342211000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/jbmr\/article\/16\/9\/1682-1687\/7515844"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,9,1]]},"references-count":23,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2009,12,2]]},"published-print":{"date-parts":[[2001,9,1]]}},"URL":"https:\/\/doi.org\/10.1359\/jbmr.2001.16.9.1682","relation":{},"ISSN":["0884-0431","1523-4681"],"issn-type":[{"value":"0884-0431","type":"print"},{"value":"1523-4681","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2001,9,1]]},"published":{"date-parts":[[2001,9,1]]}}}