{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T18:56:45Z","timestamp":1773946605647,"version":"3.50.1"},"reference-count":19,"publisher":"Optica Publishing Group","issue":"17","license":[{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/doi.org\/10.1364\/OA_License_v1#VOR"},{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/opg.optica.org\/policies\/opg-tdm-policy.json"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["2019M3A9E2066880"],"award-info":[{"award-number":["2019M3A9E2066880"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["2020R1A2C3006745"],"award-info":[{"award-number":["2020R1A2C3006745"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["opg.optica.org"],"crossmark-restriction":false},"short-container-title":["Opt. Lett."],"published-print":{"date-parts":[[2020,9,1]]},"abstract":"<jats:p>In endoscopic optical coherence tomography, a transparent protective sheath is used to protect the optics and tissue. However, the sheath causes astigmatism, which degrades transverse resolution and signal-to-noise ratio due to the cylindrical lens effect. Generally used methods for correcting this astigmatism are complex, difficult to control precisely, high-cost, and increase the dimensions of the imaging probe. To overcome these problems, we have developed an astigmatism-corrected imaging probe with an epoxy window. The astigmatism is precisely and cost-effectively adjusted controlling the curvature radius of the epoxy window, which is produced by soft lithography. Using the fiber optic fusion splicing, the fabrication process is simple. The fabricated imaging probe is almost monolithic, so its diameter is similar to that of a standard single-mode fiber. We demonstrate its astigmatism-correcting performance using focal spot analysis, imaging micro-beads and a biological sample.<\/jats:p>","DOI":"10.1364\/ol.400383","type":"journal-article","created":{"date-parts":[[2020,8,3]],"date-time":"2020-08-03T17:31:27Z","timestamp":1596475887000},"page":"4867","update-policy":"https:\/\/doi.org\/10.1364\/crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Astigmatism-corrected endoscopic imaging probe for optical coherence tomography using soft lithography"],"prefix":"10.1364","volume":"45","author":[{"given":"Min","family":"Woo Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yeon","family":"Hoon Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingchao","family":"Xing","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9819-3135","authenticated-orcid":true,"given":"Hongki","family":"Yoo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"285","published-online":{"date-parts":[[2020,8,28]]},"reference":[{"key":"ol-45-17-4867-R1","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1016\/j.jcmg.2008.06.007","volume":"1","author":"Tearney","year":"2008","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ol-45-17-4867-R2","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1016\/j.jcin.2009.06.019","volume":"2","author":"Bezerra","year":"2009","journal-title":"JACC Cardiovasc. Interv."},{"key":"ol-45-17-4867-R3","doi-asserted-by":"publisher","first-page":"17364","DOI":"10.1364\/OE.18.017364","volume":"18","author":"Kang","year":"2010","journal-title":"Opt. Express"},{"key":"ol-45-17-4867-R4","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1016\/j.gie.2008.05.014","volume":"68","author":"Suter","year":"2008","journal-title":"Gastrointest. Endosc."},{"key":"ol-45-17-4867-R5","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1364\/BOE.5.000223","volume":"5","author":"Cho","year":"2013","journal-title":"Biomed. Opt. Express"},{"key":"ol-45-17-4867-R6","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1364\/OL.42.000379","volume":"42","author":"Kim","year":"2017","journal-title":"Opt. Lett."},{"key":"ol-45-17-4867-R7","doi-asserted-by":"publisher","first-page":"1531","DOI":"10.1038\/s41467-017-01494-4","volume":"8","author":"Yuan","year":"2017","journal-title":"Nat. Commun."},{"key":"ol-45-17-4867-R8","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1007\/s13534-014-0151-1","volume":"4","author":"Kim","year":"2014","journal-title":"Biomed. Eng. Lett."},{"key":"ol-45-17-4867-R9","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1002\/lsm.22554","volume":"49","author":"Singh","year":"2017","journal-title":"Lasers Surg. Med."},{"key":"ol-45-17-4867-R10","doi-asserted-by":"publisher","first-page":"5244","DOI":"10.1364\/AO.51.005244","volume":"51","author":"Wang","year":"2012","journal-title":"Appl. Opt."},{"key":"ol-45-17-4867-R11","doi-asserted-by":"publisher","first-page":"5247","DOI":"10.1364\/OL.37.005247","volume":"37","author":"Scolaro","year":"2012","journal-title":"Opt. Lett."},{"key":"ol-45-17-4867-R12","doi-asserted-by":"publisher","first-page":"1943","DOI":"10.1364\/OL.34.001943","volume":"34","author":"Xi","year":"2009","journal-title":"Opt. Lett."},{"key":"ol-45-17-4867-R13","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1038\/s41566-018-0224-2","volume":"12","author":"Pahlevaninezhad","year":"2018","journal-title":"Nat. Photonics"},{"key":"ol-45-17-4867-R14","doi-asserted-by":"publisher","first-page":"30149","DOI":"10.1364\/OE.23.030149","volume":"23","author":"Yao","year":"2015","journal-title":"Opt. Express"},{"key":"ol-45-17-4867-R15","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1364\/OE.24.001037","volume":"24","author":"Xing","year":"2016","journal-title":"Opt. Express"},{"key":"ol-45-17-4867-R16","doi-asserted-by":"publisher","first-page":"1810","DOI":"10.1039\/c3lc50076d","volume":"13","author":"Kang","year":"2013","journal-title":"Lab Chip"},{"key":"ol-45-17-4867-R17","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1364\/OL.29.000144","volume":"29","author":"Bandres","year":"2004","journal-title":"Opt. Lett."},{"key":"ol-45-17-4867-R18","doi-asserted-by":"publisher","first-page":"e24","DOI":"10.1161\/CIRCULATIONAHA.112.000223","volume":"1","author":"Kim","year":"2014","journal-title":"Circulation"},{"key":"ol-45-17-4867-R19","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.1016\/j.jacc.2011.09.079","volume":"59","author":"Tearney","year":"2012","journal-title":"J. Am. Coll. Cardiol."}],"container-title":["Optics Letters"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/opg.optica.org\/viewmedia.cfm?URI=ol-45-17-4867&seq=0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,6]],"date-time":"2024-08-06T19:26:57Z","timestamp":1722972417000},"score":1,"resource":{"primary":{"URL":"https:\/\/opg.optica.org\/abstract.cfm?URI=ol-45-17-4867"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,28]]},"references-count":19,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2020]]},"published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1364\/ol.400383","relation":{},"ISSN":["0146-9592","1539-4794"],"issn-type":[{"value":"0146-9592","type":"print"},{"value":"1539-4794","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,28]]},"assertion":[{"value":"Optica Publishing Group","name":"publisher","label":"This article is maintained by"},{"value":"https:\/\/doi.org\/10.1364\/OL.400383","name":"articlelink","label":"Crossref DOI link to publisher maintained version"},{"value":"letter","name":"content_type","label":"Article type"},{"value":"Screened by Similarity Check","name":"cross_check","label":"Similarity check"},{"value":"Yes","order":0,"name":"peer_reviewed","label":"Peer reviewed","group":{"name":"peer_review","label":"Peer review"}},{"value":"Single blind","order":1,"name":"review_process","label":"Review process","group":{"name":"peer_review","label":"Peer review"}},{"value":"17 June 2020","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"27 July 2020","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"28 August 2020","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}},{"value":"\u00a9 2020 Optical Society of America","name":"copyright","label":"Copyright"}]}}