{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:56:01Z","timestamp":1787021761694,"version":"build-2736575974"},"update-to":[{"DOI":"10.1371\/journal.pcbi.1012467","type":"new_version","label":"New version","source":"publisher","updated":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T00:00:00Z","timestamp":1744588800000}}],"reference-count":38,"publisher":"Public Library of Science (PLoS)","issue":"3","license":[{"start":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T00:00:00Z","timestamp":1743033600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["397484323"],"award-info":[{"award-number":["397484323"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004350","name":"Studienstiftung des Deutschen Volkes","doi-asserted-by":"publisher","award":["not applicable"],"award-info":[{"award-number":["not applicable"]}],"id":[{"id":"10.13039\/501100004350","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008662","name":"Joachim Herz Stiftung","doi-asserted-by":"publisher","award":["not applicable"],"award-info":[{"award-number":["not applicable"]}],"id":[{"id":"10.13039\/100008662","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.ploscompbiol.org"],"crossmark-restriction":false},"short-container-title":["PLoS Comput Biol"],"abstract":"<jats:p>Aortic stenosis (AS) leads to alterations of supra-valvular flow patterns which can cause increased damage of red blood cell (RBC) membranes. We investigated these patient specific patterns of a severe AS patient and their reversal in healthy flow through a 4D Flow MRI-based CFD methodology. Computational models of subject-specific aortic geometries were created using in-vivo medical imaging data. Temporally and spatially resolved boundary conditions derived from 4D Flow MRI were implemented for an AS patient and a healthy subject. After validation of the in-silico results with in-vivo data, a healthy inflow profile was set for the AS patient in the CFD model. Pathological versus healthy flow fields were compared regarding their blood flow characteristics, i.e., shear stresses on RBCs and helicity. The accuracy of the 4D Flow MRI-based CFD model was proven with excellent agreement between in-vivo and in-silico velocity fields and R\u00b2 = 0.9. A pathological high shear stress region in the bulk flow was present during late systole with an increase of 125% compared to both healthy flow. The physiological bihelical structure with predominantly right-handed helices vanished for the pathological state. Instead, a left-handed helix appeared, accompanied by an overall increase in turbulent kinetic energy in areas of accumulated left-handed helicity. The validated 4D Flow MRI-based CFD model identified marked differences between AS and healthy flow. It suggests that altered turbulent and helical structures in the bulk flow are the cause for increased, potentially damaging forces acting upon RBCs in AS.<\/jats:p>","DOI":"10.1371\/journal.pcbi.1012467","type":"journal-article","created":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T14:46:54Z","timestamp":1743086814000},"page":"e1012467","update-policy":"https:\/\/doi.org\/10.1371\/journal.pcbi.corrections_policy","source":"Crossref","is-referenced-by-count":4,"title":["Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework"],"prefix":"10.1371","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-5851-3915","authenticated-orcid":true,"given":"Tianai","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christine","family":"Quast","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian","family":"B\u00f6nner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malte","family":"Kelm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Zeus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3167-7121","authenticated-orcid":true,"given":"Teresa","family":"Lemainque","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrich","family":"Steinseifer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Neidlin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2025,3,27]]},"reference":[{"issue":"3","key":"pcbi.1012467.ref001","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1002\/(SICI)1522-2586(200003)11:3<299::AID-JMRI9>3.0.CO;2-M","article-title":"Reconstruction of blood flow patterns in a human carotid bifurcation: A combined CFD and MRI study","volume":"11","author":"Q Long","year":"2000","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"pcbi.1012467.ref002","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1186\/s12968-015-0174-5","article-title":"4D flow cardiovascular magnetic resonance consensus statement","volume":"17","author":"P Dyverfeldt","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"issue":"8","key":"pcbi.1012467.ref003","first-page":"e153","article-title":"Heart Disease and Stroke Statistics-2022 Update: A Report From the American Heart Association","volume":"145","author":"CW Tsao","year":"2022","journal-title":"Circulation"},{"issue":"9","key":"pcbi.1012467.ref004","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1016\/j.medengphy.2014.06.018","article-title":"An in vitro investigation of the influence of stenosis severity on the flow in the ascending aorta","volume":"36","author":"U G\u00fclan","year":"2014","journal-title":"Med Eng Phys"},{"issue":"12","key":"pcbi.1012467.ref005","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1161\/CIRCULATIONAHA.123.064747","article-title":"Aortic Valve Stenosis Causes Accumulation of Extracellular Hemoglobin and Systemic Endothelial Dysfunction","volume":"150","author":"C Quast","year":"2024","journal-title":"Circulation"},{"issue":"7","key":"pcbi.1012467.ref006","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1046\/j.1525-1594.2002.07085.x","article-title":"Validation of the coupling of magnetic resonance imaging velocity measurements with computational fluid dynamics in a U bend","volume":"26","author":"FP Glor","year":"2002","journal-title":"Artif Organs"},{"issue":"4","key":"pcbi.1012467.ref007","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1007\/s10237-019-01137-1","article-title":"Modeling and prediction of flow-induced hemolysis: a review","volume":"18","author":"MM Faghih","year":"2019","journal-title":"Biomech Model Mechanobiol"},{"issue":"8","key":"pcbi.1012467.ref008","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1007\/s00380-017-0979-2","article-title":"Validation of numerical simulation methods in aortic arch using 4D Flow MRI","volume":"32","author":"S Miyazaki","year":"2017","journal-title":"Heart Vessels"},{"issue":"6","key":"pcbi.1012467.ref009","doi-asserted-by":"crossref","first-page":"1578","DOI":"10.1093\/ejcts\/ezv459","article-title":"Blood flow analysis of the aortic arch using computational fluid dynamics","volume":"49","author":"S Numata","year":"2016","journal-title":"Eur J Cardiothorac Surg"},{"issue":"1","key":"pcbi.1012467.ref010","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1002\/mrm.10025","article-title":"Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI","volume":"47","author":"DA Steinman","year":"2002","journal-title":"Magn Reson Med"},{"issue":"03","key":"pcbi.1012467.ref011","doi-asserted-by":"crossref","first-page":"1750046","DOI":"10.1142\/S0219519417500464","article-title":"Estimation of wall shear stress using 4d flow cardiovascular mri and computational fluid dynamics","volume":"17","author":"E Soudah","year":"2016","journal-title":"J Mech Med Biol"},{"issue":"1","key":"pcbi.1012467.ref012","doi-asserted-by":"crossref","first-page":"10.1115\/1.4037857","DOI":"10.1115\/1.4037857","article-title":"Impact of Patient-Specific Inflow Velocity Profile on Hemodynamics of the Thoracic Aorta","volume":"140","author":"P Youssefi","year":"2018","journal-title":"J Biomech Eng"},{"issue":"2","key":"pcbi.1012467.ref013","doi-asserted-by":"crossref","first-page":"026101","DOI":"10.1063\/1.5011960","article-title":"Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet","volume":"2","author":"S Pirola","year":"2018","journal-title":"APL Bioeng"},{"key":"pcbi.1012467.ref014","doi-asserted-by":"crossref","DOI":"10.3389\/fphy.2020.00138","article-title":"4DFlowNet: Super-Resolution 4D Flow MRI Using Deep Learning and Computational Fluid Dynamics","volume":"8","author":"E Ferdian","year":"2020","journal-title":"Front Phys"},{"key":"pcbi.1012467.ref015","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.cma.2016.01.007","article-title":"Geometric multiscale modeling of the cardiovascular system, between theory and practice","volume":"302","author":"A Quarteroni","year":"2016","journal-title":"Computer Methods in Applied Mechanics and Engineering"},{"issue":"119","key":"pcbi.1012467.ref016","doi-asserted-by":"crossref","first-page":"20160073","DOI":"10.1098\/rsif.2016.0073","article-title":"On the impact of modelling assumptions in multi-scale, subject-specific models of aortic haemodynamics","volume":"13","author":"J Alastruey","year":"2016","journal-title":"J R Soc Interface"},{"issue":"2","key":"pcbi.1012467.ref017","first-page":"19","article-title":"Cardiovascular Risks Associated with Gender and Aging","volume":"6","author":"JL Rodgers","year":"2019","journal-title":"J Cardiovasc Dev Dis"},{"issue":"10","key":"pcbi.1012467.ref018","doi-asserted-by":"crossref","first-page":"e56","DOI":"10.1161\/CIR.0000000000000659","article-title":"Heart Disease and Stroke Statistics-2019 Update: A Report From the American Heart Association","volume":"139","author":"EJ Benjamin","year":"2019","journal-title":"Circulation"},{"issue":"4","key":"pcbi.1012467.ref019","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1007\/s10237-012-0444-1","article-title":"Helical flows and asymmetry of blood jet in dilated ascending aorta with normally functioning bicuspid valve","volume":"12","author":"E Faggiano","year":"2013","journal-title":"Biomech Model Mechanobiol"},{"issue":"5","key":"pcbi.1012467.ref020","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1007\/s10334-021-00984-3","article-title":"Hemodynamics in a three-dimensional printed aortic model: a comparison of four-dimensional phase-contrast magnetic resonance and image-based computational fluid dynamics","volume":"35","author":"J Park","year":"2022","journal-title":"MAGMA"},{"issue":"1","key":"pcbi.1012467.ref021","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1186\/s12938-018-0485-5","article-title":"Clinical validation and assessment of aortic hemodynamics using computational fluid dynamics simulations from computed tomography angiography","volume":"17","author":"Y Zhu","year":"2018","journal-title":"Biomed Eng Online"},{"issue":"3","key":"pcbi.1012467.ref022","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1016\/j.neuroimage.2006.01.015","article-title":"User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability","volume":"31","author":"PA Yushkevich","year":"2006","journal-title":"Neuroimage"},{"issue":"2","key":"pcbi.1012467.ref023","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1080\/10255840500180799","article-title":"Shape optimization in steady blood flow: a numerical study of non-Newtonian effects","volume":"8","author":"F Abraham","year":"2005","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"4","key":"pcbi.1012467.ref024","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1007\/s13239-021-00536-9","article-title":"Analysis of Turbulence Effects in a Patient-Specific Aorta with Aortic Valve Stenosis","volume":"12","author":"EL Manchester","year":"2021","journal-title":"Cardiovasc Eng Technol"},{"issue":"7","key":"pcbi.1012467.ref025","doi-asserted-by":"crossref","first-page":"3175","DOI":"10.1016\/j.apm.2010.12.022","article-title":"Simulation of blood flow in human aorta with emphasis on outlet boundary conditions","volume":"35","author":"AC Benim","year":"2011","journal-title":"Applied Mathematical Modelling"},{"issue":"1","key":"pcbi.1012467.ref026","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1002\/jmri.26210","article-title":"Age-related changes of shape and flow dynamics in healthy adult aortas: A 4D flow MRI study","volume":"49","author":"FM Callaghan","year":"2019","journal-title":"J Magn Reson Imaging"},{"issue":"2","key":"pcbi.1012467.ref027","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1002\/jmri.25773","article-title":"Distribution of blood flow velocity in the normal aorta: Effect of age and gender","volume":"47","author":"J Garcia","year":"2018","journal-title":"J Magn Reson Imaging"},{"issue":"10","key":"pcbi.1012467.ref028","doi-asserted-by":"crossref","first-page":"e1011479","DOI":"10.1371\/journal.pcbi.1011479","article-title":"Wall shear stress and pressure patterns in aortic stenosis patients with and without aortic dilation captured by high-performance image-based computational fluid dynamics","volume":"19","author":"H Zolfaghari","year":"2023","journal-title":"PLoS Comput Biol"},{"issue":"1","key":"pcbi.1012467.ref029","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.jbiomech.2012.10.012","article-title":"Inflow boundary conditions for image-based computational hemodynamics: impact of idealized versus measured velocity profiles in the human aorta","volume":"46","author":"U Morbiducci","year":"2013","journal-title":"J Biomech"},{"issue":"2","key":"pcbi.1012467.ref030","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1002\/jmri.10243","article-title":"MRI measurement of time-resolved wall shear stress vectors in a carotid bifurcation model, and comparison with CFD predictions","volume":"17","author":"P Papathanasopoulou","year":"2003","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"pcbi.1012467.ref031","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1007\/s10439-008-9609-6","article-title":"In vivo quantification of helical blood flow in human aorta by time-resolved three-dimensional cine phase contrast magnetic resonance imaging","volume":"37","author":"U Morbiducci","year":"2009","journal-title":"Ann Biomed Eng"},{"issue":"7","key":"pcbi.1012467.ref032","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1093\/ehjci\/jex176","article-title":"Ascending aorta dilatation rates in patients with tricuspid and bicuspid aortic stenosis: the COFRASA\/GENERAC study","volume":"19","author":"C Kerneis","year":"2018","journal-title":"Eur Heart J Cardiovasc Imaging"},{"issue":"2","key":"pcbi.1012467.ref033","doi-asserted-by":"crossref","first-page":"380","DOI":"10.2463\/mrms.rev.2021-0097","article-title":"Hemodynamic Parameters for Cardiovascular System in 4D Flow MRI: Mathematical Definition and Clinical Applications","volume":"21","author":"K Itatani","year":"2022","journal-title":"Magn Reson Med Sci"},{"key":"pcbi.1012467.ref034","doi-asserted-by":"crossref","first-page":"Q57","DOI":"10.1186\/1532-429X-18-S1-Q57","article-title":"Aortic flow and wall shear stress in aortic stenosis is associated with left ventricular remodeling","volume":"18","author":"F von Knobelsdorff-Brenkenhoff","year":"2016","journal-title":"Journal of Cardiovascular Magnetic Resonance"},{"issue":"5 Pt 1","key":"pcbi.1012467.ref035","doi-asserted-by":"crossref","first-page":"2235","DOI":"10.1161\/01.CIR.88.5.2235","article-title":"Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping","volume":"88","author":"PJ Kilner","year":"1993","journal-title":"Circulation"},{"issue":"4","key":"pcbi.1012467.ref036","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1097\/00004728-200407000-00005","article-title":"Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients","volume":"28","author":"M Markl","year":"2004","journal-title":"J Comput Assist Tomogr"},{"issue":"5","key":"pcbi.1012467.ref037","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1002\/cnm.1231","article-title":"Fluid\u2013structure interaction analysis of a patient\u2010specific right coronary artery with physiological velocity and pressure waveforms","volume":"25","author":"R Torii","year":"2009","journal-title":"Commun Numer Meth Engng"},{"key":"pcbi.1012467.ref038","doi-asserted-by":"crossref","first-page":"836611","DOI":"10.3389\/fbioe.2022.836611","article-title":"Evaluation of Computational Methodologies for Accurate Prediction of Wall Shear Stress and Turbulence Parameters in a Patient-Specific Aorta","volume":"10","author":"EL Manchester","year":"2022","journal-title":"Front Bioeng Biotechnol"}],"updated-by":[{"DOI":"10.1371\/journal.pcbi.1012467","type":"new_version","label":"New version","source":"publisher","updated":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T00:00:00Z","timestamp":1744588800000}}],"container-title":["PLOS Computational Biology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pcbi.1012467","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,14]],"date-time":"2025-04-14T13:26:31Z","timestamp":1744637191000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pcbi.1012467"}},"subtitle":[],"editor":[{"given":"Stacey D.","family":"Finley","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2025,3,27]]},"references-count":38,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,3,27]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pcbi.1012467","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2024.09.09.611958","asserted-by":"object"}]},"ISSN":["1553-7358"],"issn-type":[{"value":"1553-7358","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,27]]}}}