{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T22:18:14Z","timestamp":1792102694747,"version":"4.4.0"},"reference-count":43,"publisher":"Public Library of Science (PLoS)","issue":"4","license":[{"start":{"date-parts":[[2013,4,23]],"date-time":"2013-04-23T00:00:00Z","timestamp":1366675200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0061652","type":"journal-article","created":{"date-parts":[[2013,4,23]],"date-time":"2013-04-23T22:03:29Z","timestamp":1366754609000},"page":"e61652","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":6,"title":["Suppressing Multi-Channel Ultra-Low-Field MRI Measurement Noise Using Data Consistency and Image Sparsity"],"prefix":"10.1371","volume":"8","author":[{"given":"Fa-Hsuan","family":"Lin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Panu T.","family":"Vesanen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi-Cheng","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaakko O.","family":"Nieminen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koos C. J.","family":"Zevenhoven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juhani","family":"Dabek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lauri T.","family":"Parkkonen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juha","family":"Simola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antti I.","family":"Ahonen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Risto J.","family":"Ilmoniemi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2013,4,23]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1146\/annurev.bioeng.9.060906.152010","article-title":"SQUID-detected magnetic resonance imaging in microtesla fields","volume":"9","author":"J Clarke","year":"2007","journal-title":"Annu Rev Biomed Eng"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"7857","DOI":"10.1073\/pnas.0402382101","article-title":"Microtesla MRI with a superconducting quantum interference device","volume":"101","author":"R McDermott","year":"2004","journal-title":"Proc Natl Acad Sci U S A"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/j.jmr.2005.11.005","article-title":"SQUID-detected microtesla MRI in the presence of metal","volume":"179","author":"M M\u00f6\u00dfle","year":"2006","journal-title":"J Magn Reson"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1002\/mrm.20316","article-title":"SQUID-detected MRI at 132 microT with T1-weighted contrast established at 10 microT\u2013300 mT","volume":"53","author":"SK Lee","year":"2005","journal-title":"Magn Reson Med"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1002\/mrm.22428","article-title":"SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k-space","volume":"64","author":"M Lustig","year":"2010","journal-title":"Magn Reson Med"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1002\/mrm.21117","article-title":"Artifact reduction in moving-table acquisitions using parallel imaging and multiple averages","volume":"57","author":"HP Fautz","year":"2007","journal-title":"Magn Reson Med"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1002\/mrm.10388","article-title":"SMASH navigators","volume":"49","author":"M Bydder","year":"2003","journal-title":"Magn Reson Med"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1002\/mrm.10093","article-title":"Detection and elimination of motion artifacts by regeneration of k-space","volume":"47","author":"M Bydder","year":"2002","journal-title":"Magn Reson Med"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1002\/mrm.20226","article-title":"Coil-based artifact reduction","volume":"52","author":"D Atkinson","year":"2004","journal-title":"Magn Reson Med"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1002\/mrm.22358","article-title":"Data convolution and combination operation (COCOA) for motion ghost artifacts reduction","volume":"64","author":"F Huang","year":"2010","journal-title":"Magn Reson Med"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1002\/mrm.20640","article-title":"Ghost artifact removal using a parallel imaging approach","volume":"54","author":"R Winkelmann","year":"2005","journal-title":"Magn Reson Med"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized autocalibrating partially parallel acquisitions (GRAPPA)","volume":"47","author":"MA Griswold","year":"2002","journal-title":"Magn Reson Med"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1002\/mrm.1910380414","article-title":"Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays","volume":"38","author":"DK Sodickson","year":"1997","journal-title":"Magn Reson Med"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"1629","DOI":"10.1118\/1.1386778","article-title":"A generalized approach to parallel magnetic resonance imaging","volume":"28","author":"DK Sodickson","year":"2001","journal-title":"Med Phys"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1002\/mrm.21391","article-title":"Sparse MRI: The application of compressed sensing for rapid MR imaging","volume":"58","author":"M Lustig","year":"2007","journal-title":"Magn Reson Med"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1002\/mrm.22595","article-title":"Second order total generalized variation (TGV) for MRI","volume":"65","author":"F Knoll","year":"2011","journal-title":"Magn Reson Med"},{"key":"ref17","doi-asserted-by":"crossref","unstructured":"Gentle JE (2007) Matrix algebra : theory, computations, and applications in statistics. New York, N.Y.; London: Springer. xxii, 528 p.","DOI":"10.1007\/978-0-387-70873-7"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1002\/mrm.20555","article-title":"Functional MRI using regularized parallel imaging acquisition","volume":"54","author":"FH Lin","year":"2005","journal-title":"Magn Reson Med"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1002\/mrm.10718","article-title":"Parallel imaging reconstruction using automatic regularization","volume":"51","author":"FH Lin","year":"2004","journal-title":"Magn Reson Med"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1002\/mrm.21356","article-title":"Parallel MRI reconstruction using variance partitioning regularization","volume":"58","author":"FH Lin","year":"2007","journal-title":"Magn Reson Med"},{"key":"ref21","article-title":"Hybrid ultra-low-field MRI and MEG system based on a commercial whole-head neuromagnetometer","author":"PT Vesanen","journal-title":"Magn Reson Med"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1002\/mrm.1910160203","article-title":"The NMR phased array","volume":"16","author":"PB Roemer","year":"1990","journal-title":"Magn Reson Med"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","article-title":"SENSE: sensitivity encoding for fast MRI","volume":"42","author":"KP Pruessmann","year":"1999","journal-title":"Magn Reson Med"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1002\/mrm.10718","article-title":"Parallel imaging reconstruction using automatic regularization","volume":"51","author":"F-H Lin","year":"2004","journal-title":"Magn Reson Med"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1103\/RevModPhys.65.413","article-title":"Magnetoencephalography-theory, instrumentation, and application to noninvasive studies of the working human brain","volume":"65","author":"M H\u00e4m\u00e4l\u00e4inen","year":"1993","journal-title":"Rev Mod Phys"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/BF02534144","article-title":"Signal-space projection method for separating MEG or EEG into components","volume":"35","author":"MA Uusitalo","year":"1997","journal-title":"Med Biol Eng Comput"},{"key":"ref27","first-page":"2004","article-title":"MEG recordings of DC fields using the signal space separation method (SSS)","author":"S Taulu","year":"2004","journal-title":"Neurol Clin Neurophysiol"},{"key":"ref28","first-page":"35","article-title":"MEG recordings of DC fields using the signal space separation method (SSS)","volume":"2004","author":"S Taulu","year":"2004","journal-title":"Neurol Clin Neurophysiol"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1002\/jmri.22069","article-title":"Accelerating non-contrast-enhanced MR angiography with inflow inversion recovery imaging by skipped phase encoding and edge deghosting (SPEED)","volume":"31","author":"Z Chang","year":"2010","journal-title":"J Magn Reson Imaging"},{"key":"ref30","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1109\/TMI.2011.2116123","article-title":"Signal compensation and compressed sensing for magnetization-prepared MR angiography","volume":"30","author":"T Cukur","year":"2011","journal-title":"IEEE Trans Med Imaging"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.1002\/mrm.22892","article-title":"Sparse-CAPR: highly accelerated 4D CE-MRA with parallel imaging and nonconvex compressive sensing","volume":"66","author":"JD Trzasko","year":"2011","journal-title":"Magn Reson Med"},{"key":"ref32","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1002\/mrm.21477","article-title":"Compressed sensing in dynamic MRI","volume":"59","author":"U Gamper","year":"2008","journal-title":"Magn Reson Med"},{"key":"ref33","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1002\/mrm.22172","article-title":"Radial k-t FOCUSS for high-resolution cardiac cine MRI","volume":"63","author":"H Jung","year":"2010","journal-title":"Magn Reson Med"},{"key":"ref34","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1109\/TMI.2010.2100850","article-title":"Accelerated dynamic MRI exploiting sparsity and low-rank structure: k-t SLR","volume":"30","author":"SG Lingala","year":"2011","journal-title":"IEEE Trans Med Imaging"},{"key":"ref35","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.jmr.2008.03.003","article-title":"Compressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI","volume":"192","author":"S Hu","year":"2008","journal-title":"J Magn Reson"},{"key":"ref36","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1002\/mrm.22302","article-title":"Compressed sensing in hyperpolarized 3He lung MRI","volume":"63","author":"S Ajraoui","year":"2010","journal-title":"Magn Reson Med"},{"key":"ref37","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1002\/mrm.22650","article-title":"Fast dynamic 3D MR spectroscopic imaging with compressed sensing and multiband excitation pulses for hyperpolarized 13C studies","volume":"65","author":"PE Larson","year":"2011","journal-title":"Magn Reson Med"},{"key":"ref38","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.jmr.2010.09.006","article-title":"Application of compressed sensing to in vivo 3D (1)F CSI","volume":"207","author":"T Kampf","year":"2010","journal-title":"J Magn Reson"},{"key":"ref39","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1016\/j.jmr.2010.03.005","article-title":"In vivo application of sub-second spiral chemical shift imaging (CSI) to hyperpolarized 13C metabolic imaging: comparison with phase-encoded CSI","volume":"204","author":"D Mayer","year":"2010","journal-title":"J Magn Reson"},{"key":"ref40","doi-asserted-by":"crossref","first-page":"1601","DOI":"10.1002\/mrm.22956","article-title":"Multi-contrast reconstruction with Bayesian compressed sensing","volume":"66","author":"B Bilgic","year":"2011","journal-title":"Magn Reson Med"},{"key":"ref41","article-title":"Fast cardiac T(1) mapping in mice using a model-based compressed sensing method","author":"W Li","year":"2011","journal-title":"Magn Reson Med"},{"key":"ref42","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1080\/00401706.1979.10489751","article-title":"Generalized cross-validation as a method fo choosing a good ridge parameter","volume":"21","author":"GH Golub","year":"1979","journal-title":"Technometrics"},{"key":"ref43","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1137\/0714044","article-title":"Practical approximate solutions to linear operator equations when the data are noisy","volume":"14","author":"G Wahba","year":"1977","journal-title":"SIAM J Numer Anal"}],"container-title":["PLoS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0061652","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,25]],"date-time":"2020-07-25T20:06:37Z","timestamp":1595707597000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0061652"}},"subtitle":[],"editor":[{"given":"Wang","family":"Zhan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2013,4,23]]},"references-count":43,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2013,4,23]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0061652","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,4,23]]}}}