{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:59:14Z","timestamp":1787021954993,"version":"build-2736575974"},"reference-count":34,"publisher":"Public Library of Science (PLoS)","issue":"7","license":[{"start":{"date-parts":[[2015,7,22]],"date-time":"2015-07-22T00:00:00Z","timestamp":1437523200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0132483","type":"journal-article","created":{"date-parts":[[2015,7,22]],"date-time":"2015-07-22T13:51:41Z","timestamp":1437573101000},"page":"e0132483","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":44,"title":["Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study"],"prefix":"10.1371","volume":"10","author":[{"given":"Franca","family":"Wagner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wilhelm","family":"Wimmer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lars","family":"Leidolt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mattheus","family":"Vischer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Weder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roland","family":"Wiest","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georgios","family":"Mantokoudis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco D.","family":"Caversaccio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2015,7,22]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1093\/brain\/123.4.665","article-title":"The incidence and lifetime prevalence of neurological disorders in a prospective community-based study in the UK","volume":"123","author":"BK MacDonald","year":"2000","journal-title":"Brain"},{"key":"ref2","unstructured":"Wagner J, Rademacher G, Mutze S, Mittmann P, Ernst A, Todt I. MRI artifacts caused by hearing implants: assessment of the internal auditory canal in cochlear implant users. Presented at the 13<sup>th<\/sup> International Conference on Cochlear Implants and Other Implantable Auditory Technologies 2014; P2-2-26. Available: <ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"http:\/\/epub.ub.uni-muenchen.de\/20931\/1\/CI2014_Book_of_Abstracts.pdf\" xlink:type=\"simple\">http:\/\/epub.ub.uni-muenchen.de\/20931\/1\/CI2014_Book_of_Abstracts.pdf<\/ext-link>. Accessed 2015 Jun 9."},{"key":"ref3","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1002\/bem.2250160507","article-title":"Absence of radiofrequency heating from auditory implants during magnetic resonance imaging","volume":"16","author":"CK Chou","year":"1995","journal-title":"Bioelectromagnetics"},{"key":"ref4","first-page":"724","article-title":"Evaluation of MRI compatibility of the modified nucleus multichannel auditory brainstem and cochlear implants","volume":"17","author":"JW Heller","year":"1996","journal-title":"Am J Otol"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1148\/radiology.208.3.9722849","article-title":"Cochlear implants: in vitro investigation of electromagnetic interference at MR imaging: compatibility and safety aspects","volume":"208","author":"C Teissl","year":"1998","journal-title":"Radiology"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1002\/(SICI)1522-2586(199901)9:1<26::AID-JMRI4>3.0.CO;2-H","article-title":"Magnetic resonance imaging and cochlear implants: compatibility and safety aspects","volume":"9","author":"C Teissl","year":"1999","journal-title":"J Magn Reson Imaging"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1007\/s00405-007-0576-6","article-title":"Magnetic resonance imaging with the Digisonic SP Neurelec cochlear implant","volume":"265","author":"C Vincent","year":"2008","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1017\/S0022215100144214","article-title":"The magnetless Clarion cochlear implant in a patient with neurofibromatosis 2","volume":"113","author":"J Graham","year":"1999","journal-title":"J Laryngol Otol"},{"key":"ref9","first-page":"22","article-title":"Clinical results of the CLARION magnetless cochlear implant","volume":"177","author":"BP Weber","year":"1999","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1097\/00005537-200408000-00007","article-title":"Effect of magnetic resonance imaging on internal magnet strength in Med-El Combi 40+ cochlear implants","volume":"114","author":"PA Wackym","year":"2004","journal-title":"Laryngoscope"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1097\/01.MLG.0000216807.03225.CE","article-title":"Safety study of the Cochlear Nucleus 24 device with internal magnet in the 1.5 Tesla magnetic resonance imaging scanner","volume":"116","author":"SP Gubbels","year":"2006","journal-title":"Laryngoscope"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1097\/00004728-199805000-00002","article-title":"MR compatibility of Med EL cochlear implants: clinical testing at 1.0 T","volume":"22","author":"S Youssefzadeh","year":"1998","journal-title":"J Comput Assist Tomogr"},{"key":"ref13","first-page":"512","article-title":"Clinical utilization of magnetic resonance imaging for patients with cochlear implants","volume":"112","author":"WD Baumgartner","year":"2000","journal-title":"Wien Klin Wochenschr"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1097\/00129492-200111000-00018","article-title":"Clinical application of magnetic resonance imaging in 30 cochlear implant patients","volume":"22","author":"WD Baumgartner","year":"2001","journal-title":"Otol Neurotol"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1097\/MAO.0b013e3181ec1d61","article-title":"Magnetic resonance imaging at 1.5 T after cochlear implantation","volume":"31","author":"BT Crane","year":"2010","journal-title":"Otol Neurotol"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1007\/s00405-002-0568-5","article-title":"Is magnetic resonance imaging still a contraindication in cochlear-implanted patients?","volume":"260","author":"S Schmerber","year":"2003","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/MOO.0b013e328270b8b4","article-title":"MRI compatibility issues in otology","volume":"15","author":"MH Fritsch","year":"2007","journal-title":"Curr Opin Otolaryngol Head Neck Surg"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1179\/cim.2001.2.2.98","article-title":"MRI safety of MED-EL C40\/C40+ cochlear implants","volume":"2","author":"ES Hochmair","year":"2001","journal-title":"Cochlear Implants International"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1001\/jama.1989.03420010056027","article-title":"Cochlear implants are a contraindication to MRI","volume":"261","author":"HL Abrams","year":"1989","journal-title":"JAMA"},{"key":"ref20","first-page":"28","article-title":"Clinical application of magnetic resonance imaging in cochlear-implanted patients","volume":"57","author":"WD Baumgartner","year":"2000","journal-title":"Adv Otorhinolaryngol"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1007\/s00330-012-2760-3","article-title":"Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI","volume":"23","author":"F Dubrulle","year":"2013","journal-title":"Eur Radiol"},{"key":"ref22","first-page":"739","article-title":"Thiel method fixed cadaver ears. A new procedure for graduate and continuing education in middle ear surgery","volume":"50","author":"J Alberty","year":"2002","journal-title":"HNO"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1016\/j.otohns.2008.07.026","article-title":"Demagnetization of cochlear implants and temperature changes in 3.0 T MRI environment","volume":"139","author":"O Majdani","year":"2008","journal-title":"Otolaryngol Head Neck Surg"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1159\/000346239","article-title":"Magnet removal and reinsertion in a cochlear implant recipient undergoing brain MRI","volume":"75","author":"L Migirov","year":"2013","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"key":"ref25","unstructured":"Nucleus 24: magnetic resonance imaging (MRI). Available: <ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"http:\/\/www.professionals.cochlearamericas.com\/sites\/default\/files\/resources\/MRI.pdf\" xlink:type=\"simple\">http:\/\/www.professionals.cochlearamericas.com\/sites\/default\/files\/resources\/MRI.pdf<\/ext-link>. Accessed 2013 Oct 1."},{"key":"ref26","unstructured":"MR safety information for the MED-El Mi1200 Synchrony implant; Available: <ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"http:\/\/www.medel.com\/synchrony-mri\" xlink:type=\"simple\">http:\/\/www.medel.com\/synchrony-mri<\/ext-link>. Accessed 2015 Jan 1."},{"key":"ref27","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1097\/MAO.0b013e318248eaaa","article-title":"Surgical management of vestibular schwannomas and hearing rehabilitation in neurofibromatosis type 2","volume":"33","author":"JR Tysome","year":"2012","journal-title":"Otol Neurotol"},{"key":"ref28","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1097\/MAO.0b013e3181825695","article-title":"Cochlear implant magnet displacement during magnetic resonance imaging","volume":"29","author":"S Deneuve","year":"2008","journal-title":"Otol Neurotol"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.otohns.2005.02.018","article-title":"Cochlear implant magnet displacement with minor head trauma","volume":"133","author":"JM Yun","year":"2005","journal-title":"Otolaryngol Head Neck Surg"},{"key":"ref30","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1055\/s-0033-1364170","article-title":"Intracochlear schwannoma: diagnosis and management","volume":"18","author":"AG Bittencourt","year":"2014","journal-title":"Int A Otorhinolaryngol"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"898","DOI":"10.3174\/ajnr.A1026","article-title":"Imaging of intralabyrinthine schwannomas: A retrospective study of 52 cases emphasis on lesion growth","volume":"29","author":"A Tieleman","year":"2008","journal-title":"Am J Neuroradiol"},{"key":"ref32","article-title":"MRI artifacts and cochlear implant positioning at 3T in vivo","author":"I Todt","year":"2015","journal-title":"Otol Neurotol"},{"key":"ref33","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/S0720-048X(01)00378-3","article-title":"CT and MR imaging of acquired abnormalities of the inner ear and cerebellopontine angle","volume":"40","author":"C Czerny","year":"2001","journal-title":"Eur J Radiol"},{"issue":"39","key":"ref34","first-page":"55","article-title":"Temporal bone imaging. Review article","volume":"24","author":"K Fruauff","year":"2015","journal-title":"Top Magn Reson Imaging"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0132483","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,10,23]],"date-time":"2018-10-23T22:48:48Z","timestamp":1540334928000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0132483"}},"subtitle":[],"editor":[{"given":"Sompop","family":"Bencharit","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2015,7,22]]},"references-count":34,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2015,7,22]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0132483","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,7,22]]}}}