{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T14:53:49Z","timestamp":1785336829511,"version":"3.55.0"},"reference-count":23,"publisher":"Public Library of Science (PLoS)","issue":"5","license":[{"start":{"date-parts":[[2016,5,17]],"date-time":"2016-05-17T00:00:00Z","timestamp":1463443200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Special Scientific Research Project of Health Profession","award":["201302015"],"award-info":[{"award-number":["201302015"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0155527","type":"journal-article","created":{"date-parts":[[2016,5,17]],"date-time":"2016-05-17T17:48:23Z","timestamp":1463507303000},"page":"e0155527","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":53,"title":["Changes in Corneal Biomechanical Properties after Long-Term Topical Prostaglandin Therapy"],"prefix":"10.1371","volume":"11","author":[{"given":"Na","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuhong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaobo","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mengwei","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen","family":"Wen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinghuai","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2016,5,17]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1001\/archopht.1995.01100070092031","article-title":"Risk factors for open-angle glaucoma. The Barbados Eye Study","volume":"113","author":"MC Leske","year":"1995","journal-title":"Arch Ophthalmol"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"2547","DOI":"10.1167\/iovs.14-16181","article-title":"IOP-Lowering Effect of ONO-9054, A Novel Dual Agonist of Prostanoid EP3 and FP Receptors, in Monkeys","volume":"56","author":"S Yamane","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1089\/jop.2013.0196","article-title":"Effects of long-term topical prostaglandin therapy on central corneal thickness","volume":"30","author":"Y Maruyama","year":"2014","journal-title":"J Ocul Pharmacol Ther"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1097\/IJG.0b013e31815d784c","article-title":"Comparison of the effects of latanoprost and bimatoprost on central corneal thickness","volume":"17","author":"E Sen","year":"2008","journal-title":"J Glaucoma"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1016\/j.ajo.2013.12.024","article-title":"Corneal Biomechanics as a Function of Intraocular Pressure and Pachymetry by Dynamic Infrared Signal and Scheimpflug Imaging Analysis in Normal Eyes","volume":"157","author":"T Huseynova","year":"2014","journal-title":"American Journal of Ophthalmology"},{"key":"ref6","article-title":"Effect of topical prostaglandin analogues on corneal hysteresis","author":"G Bolivar","year":"2015","journal-title":"Acta Ophthalmol"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.clae.2006.09.006","article-title":"The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyes","volume":"29","author":"S Shah","year":"2006","journal-title":"Cont Lens Anterior Eye"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"138","DOI":"10.5301\/EJO.2010.2150","article-title":"Evaluation of corneal biomechanical properties with the Reichert Ocular Response Analyzer","volume":"21","author":"M Detry-Morel","year":"2011","journal-title":"Eur J Ophthalmol"},{"key":"ref9","first-page":"1149","article-title":"The effect of prostaglandin analogs on the biomechanical properties and central thickness of the cornea of patients with open-angle glaucoma: a 3-year study on 108 eyes","volume":"7","author":"P Tsikripis","year":"2013","journal-title":"Drug Des Devel Ther"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.exer.2015.05.018","article-title":"Evaluation of the relationship of corneal biomechanical metrics with physical intraocular pressure and central corneal thickness in ex vivo rabbit eye globes","volume":"137","author":"F Bao","year":"2015","journal-title":"Exp Eye Res"},{"key":"ref11","article-title":"Corneal Deformation Parameters Provided by the Corvis-ST Pachy-Tonometer in Healthy Subjects and Glaucoma Patients","author":"ML Salvetat","year":"2014","journal-title":"J Glaucoma"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1136\/bjo.2010.196899","article-title":"The relationship between corneal hysteresis and the magnitude of intraocular pressure reduction with topical prostaglandin therapy","volume":"96","author":"DR Agarwal","year":"2012","journal-title":"Br J Ophthalmol"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1167\/iovs.13-13172","article-title":"Comparison of Three Intraocular Pressure Measurement Methods Including Biomechanical Properties of the Cornea","volume":"55","author":"A Smedowski","year":"2014","journal-title":"Investigative Ophthalmology & Visual Science"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1007\/s00417-014-2667-6","article-title":"Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry","volume":"252","author":"IB Pedersen","year":"2014","journal-title":"Graefes Archive for Clinical and Experimental Ophthalmology"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1111\/j.1442-9071.2012.02809.x","article-title":"Ocular rigidity: biomechanical role, in vivo measurements and clinical significance","volume":"41","author":"ET Detorakis","year":"2013","journal-title":"Clin Experiment Ophthalmol"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1016\/j.ophtha.2010.12.001","article-title":"Determinants of corneal biomechanical properties in an adult Chinese population","volume":"118","author":"A Narayanaswamy","year":"2011","journal-title":"Ophthalmology"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.ajo.2007.12.034","article-title":"Corneal hysteresis and axial length among Chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES) report no. 4","volume":"145","author":"Y Song","year":"2008","journal-title":"Am J Ophthalmol"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"282","DOI":"10.3109\/02713683.2014.922193","article-title":"The roles of cornea and axial length in corneal hysteresis among emmetropes and high myopes: a pilot study","volume":"40","author":"YZ Wong","year":"2015","journal-title":"Curr Eye Res"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"3852","DOI":"10.1167\/iovs.07-1670","article-title":"Cornea biomechanical characteristics and their correlates with refractive error in Singaporean children","volume":"49","author":"L Lim","year":"2008","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"558","DOI":"10.3928\/1081597X-20130719-06","article-title":"Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas","volume":"29","author":"G Nemeth","year":"2013","journal-title":"J Refract Surg"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"E1","DOI":"10.1097\/OPX.0b013e318279eb87","article-title":"Corneal Deformation Measurement Using Scheimpflug Noncontact Tonometry","volume":"90","author":"Y Hon","year":"2013","journal-title":"Optometry and Vision Science"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1097\/IJG.0b013e3181ca7c7a","article-title":"Evaluation of Prostaglandin Analogue Effects on Corneal Keratocyte Density Using Scanning Laser Confocal Microscopy","volume":"19","author":"C Bergonzi","year":"2010","journal-title":"Journal of Glaucoma"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"15","DOI":"10.4103\/0301-4738.151456","article-title":"Decreased keratocyte density and central corneal thickness in primary open-angle glaucoma patients undergoing treatment with topical prostaglandin analogues","volume":"63","author":"S Kocabeyoglu","year":"2015","journal-title":"Indian Journal of Ophthalmology"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0155527","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,18]],"date-time":"2023-08-18T07:13:33Z","timestamp":1692342813000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0155527"}},"subtitle":[],"editor":[{"given":"Dimitrios","family":"Karamichos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2016,5,17]]},"references-count":23,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2016,5,17]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0155527","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,17]]}}}