{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:59:55Z","timestamp":1787021995659,"version":"build-2736575974"},"reference-count":35,"publisher":"Public Library of Science (PLoS)","issue":"2","license":[{"start":{"date-parts":[[2017,2,21]],"date-time":"2017-02-21T00:00:00Z","timestamp":1487635200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0171941","type":"journal-article","created":{"date-parts":[[2017,2,21]],"date-time":"2017-02-21T13:27:00Z","timestamp":1487683620000},"page":"e0171941","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":23,"title":["Cataract surgery causes biomechanical alterations to the eye detectable by Corvis ST tonometry"],"prefix":"10.1371","volume":"12","author":[{"given":"Yoshitake","family":"Kato","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shunsuke","family":"Nakakura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryo","family":"Asaoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kanae","family":"Matsuya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuki","family":"Fujio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiaki","family":"Kiuchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"on behalf of the Ocular Biomechanics Study Group","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2017,2,21]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"6762","DOI":"10.1167\/iovs.15-17201","article-title":"Vision Loss Expert Group of the Global Burden of Disease Study. Number of People Blind or Visually Impaired by Cataract Worldwide and in World Regions, 1990 to 2010","volume":"56","author":"M Khairallah","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"743","DOI":"10.4103\/0301-4738.171020","article-title":"The effect of phacoemulsification surgery on intraocular pressure and anterior segment anatomy of the patients with cataract and ocular hypertension","volume":"63","author":"S Cetinkaya","year":"2015","journal-title":"Indian J Ophthalmol"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.ajo.2013.08.023","article-title":"The effect of phacoemulsification on intraocular pressure in medically controlled open-angle glaucoma patients","volume":"157","author":"MA Slabaugh","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"7807","DOI":"10.1167\/iovs.15-17926","article-title":"Lens Position Parameters as Predictors of Intraocular Pressure Reduction After Cataract Surgery in Nonglaucomatous Patients With Open Angles","volume":"56","author":"CH Hsu","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"7951","DOI":"10.1167\/iovs.12-10231","article-title":"Elevated levels of monocyte chemoattractant protein-1 in the aqueous humor after phacoemulsification","volume":"53","author":"M Kawai","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1016\/j.jcrs.2014.02.032","article-title":"Deformation response of paired donor corneas to an air puff: intact whole globe versus mounted corneoscleral rim","volume":"40","author":"KM Metzler","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1097\/ICO.0b013e3181d9284b","article-title":"Time course of corneal biomechanical parameters after phacoemulsification with intraocular lens implantation","volume":"29","author":"K Kamiya","year":"2010","journal-title":"Cornea"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"2096","DOI":"10.1016\/j.jcrs.2008.08.017","article-title":"Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantation","volume":"34","author":"RB Kucumen","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1016\/j.jcrs.2014.04.019","article-title":"Concepts and misconceptions in corneal biomechanics","volume":"40","author":"CJ Roberts","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"2474","DOI":"10.1167\/iovs.12-11424","article-title":"Evaluation of corneal displacement using high-speed photography at the early and late phases of noncontact tonometry","volume":"54","author":"S Nakakura","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"e96066","DOI":"10.1371\/journal.pone.0096066","article-title":"Ocular surface displacement with and without contact lenses during non-contact tonometry","volume":"9","author":"U Rimayanti","year":"2014","journal-title":"PLoS One"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/s10384-012-0131-x","article-title":"Corneal displacement during tonometry with a noncontact tonometer","volume":"56","author":"Y Kiuchi","year":"2012","journal-title":"Jpn J Ophthalmol"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1167\/iovs.12-10984","article-title":"A new tonometer\u2014the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers","volume":"54","author":"J Hong","year":"2013","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"e0140385","DOI":"10.1371\/journal.pone.0140385","article-title":"The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature","volume":"10","author":"R Asaoka","year":"2015","journal-title":"PLoS One"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"558","DOI":"10.3928\/1081597X-20130719-06","article-title":"Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas","volume":"29","author":"G Nemeth","year":"2013","journal-title":"J Refract Surg"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"e603","DOI":"10.1097\/IJG.0000000000000284","article-title":"Novel parameter of corneal biomechanics that differentiate normals from glaucoma","volume":"25","author":"R Lee","year":"2016","journal-title":"J Glaucoma"},{"key":"ref17","article-title":"Corneal biomechanical characteristics measured by the CorVis Scheimpflug technology in eyes with primary open-angle glaucoma and normal eyes","author":"L Tian","year":"2015","journal-title":"Acta Ophthalmol"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"5557","DOI":"10.1167\/iovs.15-16926","article-title":"Corneal Deformation Response in Patients With Primary Open-Angle Glaucoma and in Healthy Subjects Analyzed by Corvis ST","volume":"56","author":"W Wang","year":"2015","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"e193","DOI":"10.1111\/aos.12530","article-title":"Effect of diabetes mellitus on Corvis ST measurement process","volume":"93","author":"C P\u00e9rez-Rico","year":"2015","journal-title":"Acta Ophthalmol"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"1404","DOI":"10.1097\/ICO.0000000000000598","article-title":"Screening for Keratoconus With New Dynamic Biomechanical In Vivo Scheimpflug Analyses","volume":"34","author":"J Steinberg","year":"2015","journal-title":"Cornea"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1007\/s10384-014-0344-2","article-title":"Corneal biomechanical properties in 3 corneal transplantation techniques with a dynamic Scheimpflug analyzer","volume":"58","author":"N Maeda","year":"2014","journal-title":"Jpn J Ophthalmol"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.clae.2014.05.001","article-title":"Examination of ocular biomechanics with a new Scheimpflug technology after corneal refractive surgery","volume":"37","author":"Z Hassan","year":"2014","journal-title":"Cont Lens Anterior Eye"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.jcrs.2015.07.047","article-title":"Changes in ocular biomechanics after femtosecond laser creation of a laser in situ keratomileusis flap","volume":"42","author":"A Leccisotti","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"ref24","first-page":"185","article-title":"Evaluation of corneal biomechanics with a high-speed Scheimpflug camera before and after cataract surgery: the role of intraocular pressure","volume":"4","author":"Miguel Ru\u00e3o","year":"2015","journal-title":"J Emmtropia"},{"key":"ref25","article-title":"In Vivo Corneal Biomechanical Properties with Corneal Visualization Scheimpflug Technology in Chinese Population","author":"Y Wu","year":"2016","journal-title":"Biomed Res Int"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1177\/0049124104268644","article-title":"Multimodel inference: understanding: AIC and BIC in model selection","volume":"33","author":"KP Burnham","year":"2004","journal-title":"Sociological Methods & Research"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1214\/12-AOS1003","article-title":"Degrees of freedom in lasso problems","volume":"40","author":"RJ Tibshirani","year":"2012","journal-title":"Annals of Statistics"},{"key":"ref28","article-title":"Evaluation of Corneal Deformation Parameters Provided by the Corvis ST Tonometer After Trabeculectomy","author":"Y Zong","year":"2016","journal-title":"J Glaucoma"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1111\/j.1442-9071.2012.02830.x","article-title":"Elastic hysteresis in human eyes is an age-dependent value","volume":"41","author":"K Ishii","year":"2013","journal-title":"Clin Experiment Ophthalmol"},{"key":"ref30","doi-asserted-by":"crossref","first-page":"3919","DOI":"10.1167\/iovs.07-1321","article-title":"A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis","volume":"49","author":"DH Glass","year":"2008","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.jcrs.2009.07.035","article-title":"Real-time intraocular pressure measurement in standard and microcoaxial phacoemulsification","volume":"36","author":"TC Kreutzer","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"ref32","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.1136\/bjo.84.9.1056","article-title":"Anterior chamber flare after trabeculectomy and after phacoemulsification","volume":"84","author":"D Siriwardena","year":"2000","journal-title":"Br J Ophthalmol"},{"key":"ref33","first-page":"1410","article-title":"Effect of cataract surgery on aqueous TGF-beta and lens epithelial cell proliferation","volume":"39","author":"N Wallentin","year":"1998","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref34","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/S0886-3350(98)80208-3","article-title":"Intraocular pressure change after sutureless phacoemulsification and foldable posterior chamber lens implantation","volume":"24","author":"JT Tong","year":"1998","journal-title":"J Cataract Refract Surg"},{"key":"ref35","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/S0886-3350(00)00577-0","article-title":"Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision","volume":"27","author":"O Schwenn","year":"2001","journal-title":"J Cataract Refract Surg"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0171941","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,10,23]],"date-time":"2018-10-23T23:56:22Z","timestamp":1540338982000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0171941"}},"subtitle":[],"editor":[{"given":"Andreas","family":"Wedrich","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2017,2,21]]},"references-count":35,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2017,2,21]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0171941","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,2,21]]}}}