{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T23:46:54Z","timestamp":1779925614090,"version":"3.53.1"},"reference-count":30,"publisher":"Public Library of Science (PLoS)","issue":"1","license":[{"start":{"date-parts":[[2018,1,5]],"date-time":"2018-01-05T00:00:00Z","timestamp":1515110400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0190584","type":"journal-article","created":{"date-parts":[[2018,1,5]],"date-time":"2018-01-05T14:09:00Z","timestamp":1515161340000},"page":"e0190584","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":7,"title":["Effectiveness of automatic tube potential selection with tube current modulation in coronary CT angiography for obese patients: Comparison with a body mass index-based protocol using the propensity score matching method"],"prefix":"10.1371","volume":"13","author":[{"given":"Hong Seon","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2078-5832","authenticated-orcid":true,"given":"Young Joo","family":"Suh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyunghwa","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin Young","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suyon","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Jin","family":"Im","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoo Jin","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hye-Jeong","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Hur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Jin","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byoung Wook","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2018,1,5]]},"reference":[{"issue":".","key":"ref1","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/S0140-6736(14)60460-8","article-title":"Global, regional, and national prevalence of overweight and obesity in children and adults during 1980\u20132013: a systematic analysis for the Global Burden of Disease Study 2013","volume":"384","author":"M Ng","journal-title":"The Lancet"},{"issue":"9536","key":"ref2","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1016\/S0140-6736(06)69251-9","article-title":"Association of bodyweight with total mortality and with cardiovascular events in coronary artery disease: a systematic review of cohort studies","volume":"368","author":"A Romero-Corral","journal-title":"The Lancet"},{"issue":"3","key":"ref3","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.acra.2005.11.036","article-title":"Correlation between image noise and body weight in coronary CTA with 16-row MDCT","volume":"13","author":"N Yoshimura","year":"2006","journal-title":"Academic radiology"},{"issue":"3","key":"ref4","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.jacc.2005.05.056","article-title":"Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography","volume":"46","author":"GL Raff","year":"2005","journal-title":"Journal of the American College of Cardiology"},{"issue":"3","key":"ref5","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.jcct.2012.04.002","article-title":"Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol","volume":"6","author":"YJ Park","year":"2012","journal-title":"Journal of cardiovascular computed tomography"},{"issue":"5","key":"ref6","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.jcct.2013.08.010","article-title":"Automated attenuation-based selection of tube voltage and tube current for coronary CT angiography: reduction of radiation exposure versus a BMI-based strategy with an expert investigator","volume":"7","author":"C Layritz","year":"2013","journal-title":"Journal of cardiovascular computed tomography"},{"issue":"3","key":"ref7","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1148\/radiol.13130408","article-title":"Combined use of automatic tube potential selection with tube current modulation and iterative reconstruction technique in coronary CT angiography","volume":"269","author":"YJ Suh","year":"2013","journal-title":"Radiology"},{"key":"ref8","article-title":"Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison","author":"AW Krazinski","year":"2014","journal-title":"European radiology"},{"key":"ref9","article-title":"Image quality and required radiation dose for coronary computed tomography angiography using an automatic tube potential selection technique","author":"Y Wang","year":"2014","journal-title":"The international journal of cardiovascular imaging"},{"issue":"10","key":"ref10","doi-asserted-by":"crossref","first-page":"3608","DOI":"10.1007\/s00330-015-4191-4","article-title":"Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3(rd) generation dual-source CT","volume":"26","author":"S Mangold","year":"2016","journal-title":"European radiology"},{"issue":"1","key":"ref11","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1097\/RTI.0b013e3182631e8a","article-title":"Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality","volume":"28","author":"BB Ghoshhajra","year":"2013","journal-title":"Journal of thoracic imaging"},{"issue":"2","key":"ref12","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1148\/radiol.12112434","article-title":"Attenuation-based automatic tube voltage selection and tube current modulation for dose reduction at contrast-enhanced liver CT","volume":"265","author":"KH Lee","year":"2012","journal-title":"Radiology"},{"issue":"4","key":"ref13","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.2214\/AJR.08.1025","article-title":"Image quality in a low radiation exposure protocol for retrospectively ECG-gated coronary CT angiography","volume":"192","author":"T Pflederer","year":"2009","journal-title":"AJR American journal of roentgenology"},{"issue":"8","key":"ref14","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1016\/j.jcmg.2009.02.015","article-title":"Impact of a reduced tube voltage on CT angiography and radiation dose: results of the PROTECTION I study","volume":"2","author":"B Bischoff","year":"2009","journal-title":"JACC Cardiovascular imaging"},{"issue":"11","key":"ref15","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1016\/j.jcmg.2010.08.016","article-title":"Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II Trial","volume":"3","author":"J Hausleiter","year":"2010","journal-title":"JACC Cardiovascular imaging"},{"issue":"4","key":"ref16","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.jcct.2011.06.001","article-title":"SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT","volume":"5","author":"SS Halliburton","year":"2011","journal-title":"Journal of cardiovascular computed tomography"},{"issue":"3","key":"ref17","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1148\/radiol.12112365","article-title":"Size-specific dose estimates for adult patients at CT of the torso","volume":"265","author":"JA Christner","year":"2012","journal-title":"Radiology"},{"issue":"11","key":"ref18","doi-asserted-by":"crossref","first-page":"2677","DOI":"10.1007\/s00330-014-3312-9","article-title":"Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison","volume":"24","author":"AW Krazinski","year":"2014","journal-title":"European radiology"},{"issue":"12","key":"ref19","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1097\/RLI.0b013e3182266448","article-title":"Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: improved dose effectiveness","volume":"46","author":"A Winklehner","year":"2011","journal-title":"Investigative radiology"},{"issue":"1","key":"ref20","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1148\/radiol.2015141507","article-title":"Effect of automated attenuation-based tube voltage selection on radiation dose at CT: an observational study on a global scale","volume":"279","author":"JV Spearman","year":"2015","journal-title":"Radiology"},{"issue":"1","key":"ref21","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1002\/ajpa.20262","article-title":"Relationship between adiposity and body size reveals limitations of BMI","volume":"129","author":"AM Nevill","year":"2006","journal-title":"American journal of physical anthropology"},{"issue":"10","key":"ref22","first-page":"1007","article-title":"[Influence of body mass index on coronary artery opacification in 64-slice CT angiography]","volume":"178","author":"L Husmann","year":"2006","journal-title":"RoFo: Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin"},{"issue":"3","key":"ref23","doi-asserted-by":"crossref","first-page":"777","DOI":"10.2214\/AJR.07.2765","article-title":"Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity","volume":"190","author":"KT Bae","year":"2008","journal-title":"American Journal of Roentgenology"},{"issue":"8","key":"ref24","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1016\/j.amjcard.2010.06.032","article-title":"Effect of increasing body mass index on image quality and positive predictive value of 100-kV coronary computed tomographic angiography","volume":"106","author":"JS Ho","year":"2010","journal-title":"The American journal of cardiology"},{"issue":"3","key":"ref25","doi-asserted-by":"crossref","first-page":"635","DOI":"10.2214\/AJR.08.1390","article-title":"Evaluation of a body mass index\u2013adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering","volume":"192","author":"F Tatsugami","year":"2009","journal-title":"American Journal of Roentgenology"},{"issue":"12","key":"ref26","doi-asserted-by":"crossref","first-page":"2560","DOI":"10.1007\/s00330-003-2111-5","article-title":"Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart","volume":"13","author":"B Jung","year":"2003","journal-title":"European radiology"},{"issue":"3","key":"ref27","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.ejrad.2008.08.015","article-title":"Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters","volume":"68","author":"H Alkadhi","year":"2008","journal-title":"European journal of radiology"},{"issue":"5","key":"ref28","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1177\/0284185113502745","article-title":"Coronary computed tomography angiography at 140 kV versus 120 kV: assessment of image quality and radiation exposure in overweight and moderately obese patients","volume":"55","author":"AM Lee","year":"2014","journal-title":"Acta Radiologica"},{"issue":"1058","key":"ref29","doi-asserted-by":"crossref","first-page":"20150068","DOI":"10.1259\/bjr.20150068","article-title":"Dose reduction with iterative reconstruction for coronary CT angiography: a systematic review and meta-analysis","volume":"89","author":"AM Den Harder","year":"2016","journal-title":"Br J Radiol"},{"issue":"4","key":"ref30","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1016\/j.acra.2015.12.007","article-title":"Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity","volume":"23","author":"Y-N Pan","journal-title":"Academic radiology"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0190584","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,10,23]],"date-time":"2018-10-23T06:02:39Z","timestamp":1540274559000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0190584"}},"subtitle":[],"editor":[{"given":"Otavio Rizzi","family":"Coelho-Filho","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2018,1,5]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,1,5]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0190584","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,5]]}}}