{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:58:13Z","timestamp":1740146293996,"version":"3.37.3"},"reference-count":23,"publisher":"Public Library of Science (PLoS)","issue":"1","license":[{"start":{"date-parts":[[2018,1,11]],"date-time":"2018-01-11T00:00:00Z","timestamp":1515628800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/publicdomain\/zero\/1.0\/"}],"funder":[{"DOI":"10.13039\/100000125","name":"National Institute for Occupational Safety and Health","doi-asserted-by":"publisher","award":["Intramural NORA"],"award-info":[{"award-number":["Intramural NORA"]}],"id":[{"id":"10.13039\/100000125","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0191165","type":"journal-article","created":{"date-parts":[[2018,1,11]],"date-time":"2018-01-11T20:17:53Z","timestamp":1515701873000},"page":"e0191165","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":9,"title":["Changes in respiratory and non-respiratory symptoms in occupants of a large office building over a period of moisture damage remediation attempts"],"prefix":"10.1371","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4419-9341","authenticated-orcid":true,"given":"Ju-Hyeong","family":"Park","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sook Ja","family":"Cho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra K.","family":"White","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean M.","family":"Cox-Ganser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2018,1,11]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1289\/ehp.1002410","article-title":"Respiratory and allergic health effects of dampness, mold and dampness-related agents: A review of the epidemiologic evidence","volume":"119","author":"M Mendell","year":"2011","journal-title":"Environ Health Perspect"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"757","DOI":"10.2741\/e284","article-title":"Mold exposure and respiratory health in damp indoor environments","volume":"3","author":"J Park","year":"2011","journal-title":"Front Biosc"},{"year":"2009","key":"ref3"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1111\/j.1600-0668.2007.00474.x","article-title":"Public health and economic impact of dampness and mold","volume":"17","author":"D Mudarri","year":"2007","journal-title":"Indoor Air"},{"issue":"9","key":"ref5","first-page":"1","article-title":"Remediating buildings damaged by dampness and mould for preventing or reducing respiratory tract symptoms, infections and asthma (review)","author":"R Sauni","year":"2011","journal-title":"Cochrane Database Systematic Review"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1111\/j.1600-0668.2011.00722.x","article-title":"Levels of microbial agents in floor dust during remediation of a water-damaged office building","volume":"21","author":"S Cho","year":"2011","journal-title":"Indoor Air"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1289\/ehp.7559","article-title":"Respiratory morbidity in office workers in a water-damaged building","volume":"113","author":"J Cox-Ganser","year":"2005","journal-title":"Environ Health Perspect"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1111\/j.1600-0668.2005.00415.x","article-title":"Fungal and endotoxin measurements in dust associated with respiratory symptoms in a water-damaged office building","volume":"16","author":"J Park","year":"2006","journal-title":"Indoor Air"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1289\/ehp.10355","article-title":"Hydrophilic fungi and ergosterol associated with respiratory illness in a water-damaged building","volume":"116","author":"J Park","year":"2008","journal-title":"Environ Health Perspect"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/S0013-9351(05)80081-7","article-title":"Environmental endotoxin measurement: the Kinetic Limulus Assay with Resistant-parallel-line Estimation","volume":"57","author":"D Milton","year":"1992","journal-title":"Environ Res"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"2554","DOI":"10.1128\/AEM.63.7.2554-2559.1997","article-title":"Quantification of ergosterol and 3-hydroxy fatty acids in settled house dust by gas chromatography-mass spectrometry: Comparison with fungal culture and determination of endotoxin by a Limulus amebocyte lysate assay","volume":"63","author":"A Saraf","year":"1997","journal-title":"Appl Environ Microbiol"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"5142","DOI":"10.1016\/j.csda.2006.05.021","article-title":"Robustness of the linear mixed model to misspecified error distribution","volume":"51","author":"H Jacqmin-Gadda","year":"2007","journal-title":"Computational Statistics & Data Analysis"},{"key":"ref13","first-page":"36","article-title":"The remediation of mold damaged school\u2014a three-year follow-up study on teachers&apos; health","volume":"12","author":"R Patovirta","year":"2004","journal-title":"Cent Eur J Public Health"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1034\/j.1600-0668.2002.01112.x","article-title":"Slowly decreasing mucosal hyperreactivity years after working in a school with moisture problems","volume":"12","author":"S Rudblad","year":"2002","journal-title":"Indoor Air"},{"key":"ref15","unstructured":"Park, J, White, S, Cho, S, and Cox-Ganser, J. Evaluation of respiratory health among employees in a water-damaged office building\u2014Connecticut. NIOSH Report No. 2001-0445-3141. 2011. Available at <ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/www.cdc.gov\/niosh\/nioshtic-2\/20039838.html\" xlink:type=\"simple\">https:\/\/www.cdc.gov\/niosh\/nioshtic-2\/20039838.html<\/ext-link>"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1002\/ajim.20910","article-title":"Lack of respiratory improvement following remediation of a water-damaged office building","volume":"54","author":"Y Iossifova","year":"2011","journal-title":"Am J Ind Med"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1111\/j.1600-0668.2012.00775.x","article-title":"Rhinosinusitis and mold as risk factors for asthma symptoms in occupants of a water-damaged building","volume":"22","author":"J Park","year":"2012","journal-title":"Indoor Air"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.scitotenv.2008.03.033","article-title":"Monitoring success of remediation: seven case studies of moisture and mold damaged buildings","volume":"399","author":"U Haverinen-Shaughnessy","year":"2008","journal-title":"Sci Total Environ"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1038\/jes.2012.89","article-title":"Evaluation of individual-based and group-based exposure estimation of microbial agents in health effects associated with a damp building","volume":"23","author":"S Cho","year":"2013","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1080\/10473220117482","article-title":"Allergic respiratory disease and fungal remediation in a building in a subtropical climate","volume":"16","author":"J Jarvis","year":"2001","journal-title":"Appl Occup Environ Hyg"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1289\/ehp.8742","article-title":"Reduction in asthma morbidity in children as a result of home remediation aimed at moisture sources","volume":"114","author":"C Kercsmar","year":"2006","journal-title":"Environ Health Perspect"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1080\/09603120400012876","article-title":"Effects of mould remediation on school teachers&apos; health","volume":"14","author":"R Patovirta","year":"2004","journal-title":"Int J Environ Health Res"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1034\/j.1600-0668.2002.02141.x","article-title":"Building-related symptoms and molds: A two-step intervention study","volume":"12","author":"N Ebbehoj","year":"2002","journal-title":"Indoor Air"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0191165","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,25]],"date-time":"2020-10-25T14:12:56Z","timestamp":1603635176000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0191165"}},"subtitle":[],"editor":[{"given":"Christophe","family":"Leroyer","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2018,1,11]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,1,11]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0191165","relation":{},"ISSN":["1932-6203"],"issn-type":[{"type":"electronic","value":"1932-6203"}],"subject":[],"published":{"date-parts":[[2018,1,11]]}}}