{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T22:45:52Z","timestamp":1768344352370,"version":"3.49.0"},"reference-count":30,"publisher":"Public Library of Science (PLoS)","issue":"10","license":[{"start":{"date-parts":[[2018,10,3]],"date-time":"2018-10-03T00:00:00Z","timestamp":1538524800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0204794","type":"journal-article","created":{"date-parts":[[2018,10,3]],"date-time":"2018-10-03T14:02:19Z","timestamp":1538575339000},"page":"e0204794","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":5,"title":["Automated tube voltage selection in pediatric non-contrast chest CT"],"prefix":"10.1371","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4556-1931","authenticated-orcid":true,"given":"Azadeh","family":"Hojreh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Homolka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jutta","family":"Gamper","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0505-4919","authenticated-orcid":true,"given":"Sylvia","family":"Unterhumer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniela","family":"Kienzl-Palma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0107-3327","authenticated-orcid":true,"given":"Csilla","family":"Balassy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4915-4620","authenticated-orcid":true,"given":"Thomas","family":"Wrba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helmut","family":"Prosch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2018,10,3]]},"reference":[{"issue":"9840","key":"ref1","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/S0140-6736(12)60815-0","article-title":"Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study","volume":"380","author":"MS Pearce","year":"2012","journal-title":"The Lancet"},{"key":"ref2","first-page":"f2360","article-title":"Cancer risk in 680,000 people exposed to computed tomography scans in childhood or adolescence: data linkage study of 11 million Australians","volume":"346","author":"JD Mathews","year":"2013","journal-title":"BMJ (Clinical research ed)"},{"key":"ref3","article-title":"Effect of staff training on radiation dose in pediatric CT","author":"A Hojreh","year":"2015","journal-title":"European journal of radiology"},{"issue":"7","key":"ref4","doi-asserted-by":"crossref","first-page":"1098","DOI":"10.1016\/j.ejrad.2011.12.008","article-title":"Computerized tomography in pediatric oncology","volume":"82","author":"C Granata","year":"2013","journal-title":"European journal of radiology"},{"issue":"7","key":"ref5","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1016\/j.ejrad.2011.11.041","article-title":"CT in children\u2014dose protection and general considerations when planning a CT in a child","volume":"82","author":"E Sorantin","year":"2013","journal-title":"European journal of radiology"},{"key":"ref6","article-title":"Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII\u2013Phase 2","year":"2006"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed Tomography\u2014An Increasing Source of Radiation Exposure","volume":"357","author":"DJ Brenner","year":"2007","journal-title":"N Engl J Med"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1148\/rg.285075075","article-title":"Radiation Dose Modulation Techniques in the Multidetector CT Era: From Basics to Practice","volume":"28","author":"CH Lee","year":"2008","journal-title":"RadioGraphics"},{"issue":"10","key":"ref9","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.3109\/02841850903241914","article-title":"Use of automatic tube current modulation with a standardized noise index in young children undergoing chest computed tomography scans with 64-slice multidetector computed tomography","volume":"50","author":"Y Peng","year":"2009","journal-title":"Acta radiologica"},{"issue":"4","key":"ref10","doi-asserted-by":"crossref","first-page":"868","DOI":"10.2214\/AJR.09.4091","article-title":"Image gently: Ten steps you can take to optimize image quality and lower CT dose for pediatric patients","volume":"194","author":"KJ Strauss","year":"2010","journal-title":"AJR American journal of roentgenology"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1148\/rg.313105079","article-title":"Optimal Tube Potential for Radiation Dose Reduction in Pediatric CT: Principles, Clinical Implementations, and Pitfalls","volume":"31","author":"L Yu","year":"2011","journal-title":"RadioGraphics"},{"issue":"5","key":"ref12","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.2214\/AJR.12.8637","article-title":"Lowering kilovoltage to reduce radiation dose in contrast-enhanced abdominal CT: initial assessment of a prototype automated kilovoltage selection tool","volume":"199","author":"DM Hough","year":"2012","journal-title":"AJR American journal of roentgenology"},{"issue":"12","key":"ref13","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1097\/RLI.0b013e3182266448","article-title":"Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography: improved dose effectiveness","volume":"46","author":"A Winklehner","year":"2011","journal-title":"Investigative radiology"},{"issue":"8","key":"ref14","doi-asserted-by":"crossref","first-page":"2346","DOI":"10.1007\/s00330-015-3632-4","article-title":"Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT","volume":"25","author":"A Winklehner","year":"2015","journal-title":"European radiology"},{"issue":"3","key":"ref15","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1148\/radiol.13130408","article-title":"Combined use of automatic tube potential selection with tube current modulation and iterative reconstruction technique in coronary CT angiography","volume":"269","author":"YJ Suh","year":"2013","journal-title":"Radiology"},{"issue":"11","key":"ref16","doi-asserted-by":"crossref","first-page":"2677","DOI":"10.1007\/s00330-014-3312-9","article-title":"Reduced radiation dose and improved image quality at cardiovascular CT angiography by automated attenuation-based tube voltage selection: intra-individual comparison","volume":"24","author":"AW Krazinski","year":"2014","journal-title":"European radiology"},{"issue":"7","key":"ref17","doi-asserted-by":"crossref","first-page":"1725","DOI":"10.1007\/s00330-014-3197-7","article-title":"Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT\u2014a comparison to fixed kV with mAs modulation alone","volume":"24","author":"C Frellesen","year":"2014","journal-title":"European radiology"},{"issue":"8","key":"ref18","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1097\/RLI.0b013e318289f918","article-title":"Automated low-kilovoltage selection in pediatric computed tomography angiography: phantom study evaluating effects on radiation dose and image quality","volume":"48","author":"MJ Siegel","year":"2013","journal-title":"Investigative radiology"},{"issue":"2","key":"ref19","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1148\/radiol.13122438","article-title":"Effects of automated kilovoltage selection technology on contrast-enhanced pediatric CT and CT angiography","volume":"268","author":"MJ Siegel","year":"2013","journal-title":"Radiology"},{"key":"ref20","unstructured":"Grant K, Schmidt B. CARE kV-Automated Dose-Optimized Selection of X-ray Tube Voltage-White Paper. USA 2011 Contract No.: A9115-11314-C1-4A00."},{"issue":"11","key":"ref21","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1164\/rccm.201311-2099CI","article-title":"Monitoring cystic fibrosis lung disease by computed tomography. Radiation risk in perspective","volume":"189","author":"W Kuo","year":"2014","journal-title":"American journal of respiratory and critical care medicine"},{"issue":"Suppl 1","key":"ref22","doi-asserted-by":"crossref","first-page":"S43","DOI":"10.1016\/j.jcf.2014.03.011","article-title":"European Cystic Fibrosis Society Standards of Care: Quality Management in cystic fibrosis","volume":"13","author":"M Stern","year":"2014","journal-title":"J Cyst Fibros"},{"issue":"Suppl 1","key":"ref23","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1016\/j.jcf.2014.03.009","article-title":"European Cystic Fibrosis Society Standards of Care: Framework for the Cystic Fibrosis Centre","volume":"13","author":"S Conway","year":"2014","journal-title":"J Cyst Fibros"},{"issue":"Suppl 1","key":"ref24","doi-asserted-by":"crossref","first-page":"S23","DOI":"10.1016\/j.jcf.2014.03.010","article-title":"European Cystic Fibrosis Society Standards of Care: Best Practice guidelines","volume":"13","author":"AR Smyth","year":"2014","journal-title":"J Cyst Fibros"},{"key":"ref25","article-title":"IAEA human health Series No. 24. Dosimetry In Diagnostic Radiology For Paediatric Patients","year":"2013"},{"key":"ref26","article-title":"Diagnostic reference levels in X-ray diagnostics \u2015 Monitoring of the compliance","year":"2010"},{"key":"ref27","unstructured":"AAPM. AAPM Report No. 204: Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations. <ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"http:\/\/www.aapm.org\/pubs\/reports\/RPT_204.pdf\" xlink:type=\"simple\">http:\/\/www.aapm.org\/pubs\/reports\/RPT_204.pdf<\/ext-link> American Association of Physicists in Medicine, 2011 204."},{"issue":"1","key":"ref28","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","article-title":"The measurement of observer agreement for categorical data","volume":"33","author":"JR Landis","year":"1977","journal-title":"Biometrics"},{"issue":"1","key":"ref29","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1148\/radiol.2015141507","article-title":"Effect of Automated Attenuation-based Tube Voltage Selection on Radiation Dose at CT: An Observational Study on a Global Scale","volume":"279","author":"JV Spearman","year":"2016","journal-title":"Radiology"},{"issue":"2","key":"ref30","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1148\/radiology.217.2.r00nv35430","article-title":"Technique factors and image quality as functions of patient weight at abdominal CT","volume":"217","author":"W Huda","year":"2000","journal-title":"Radiology"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0204794","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,10,22]],"date-time":"2018-10-22T14:17:16Z","timestamp":1540217836000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0204794"}},"subtitle":[],"editor":[{"given":"Gayle E.","family":"Woloschak","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2018,10,3]]},"references-count":30,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2018,10,3]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0204794","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,3]]}}}