{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:00:38Z","timestamp":1740146438755,"version":"3.37.3"},"reference-count":20,"publisher":"Public Library of Science (PLoS)","issue":"10","license":[{"start":{"date-parts":[[2018,10,18]],"date-time":"2018-10-18T00:00:00Z","timestamp":1539820800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["81402231"],"award-info":[{"award-number":["81402231"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Science Foundation of China","award":["(grant no. 81402231)"],"award-info":[{"award-number":["(grant no. 81402231)"]}]},{"name":"the basic and frontier technology research projects by Science and Technology Department of Henan province","award":["(grant no.142300410315)"],"award-info":[{"award-number":["(grant no.142300410315)"]}]}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0204797","type":"journal-article","created":{"date-parts":[[2018,10,18]],"date-time":"2018-10-18T17:33:41Z","timestamp":1539884021000},"page":"e0204797","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effects of low-dose energy spectrum scanning combined with adaptive statistical iterative reconstruction on the quality of imaging in Budd-Chiari syndrome"],"prefix":"10.1371","volume":"13","author":[{"given":"Lei","family":"Su","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liyang","family":"Chang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lili","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5688-6088","authenticated-orcid":true,"given":"Jianbo","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2018,10,18]]},"reference":[{"key":"ref1","article-title":"Value of blood flow velocity on color Doppler ultrasonography for optimization of delay in scanning time on computed tomography venography in patients with Budd-Chiari syndrome and inferior vena cava obstruction","author":"PL Zhou","year":"2017","journal-title":"Radiol Med"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1007\/s11547-015-0602-5","article-title":"Utilizing gemstone spectral CT imaging to evaluate the therapeutic efficacy of radiofrequency ablation in lung cancer","volume":"121","author":"L Liu","year":"2016","journal-title":"Radiol Med"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.ejrad.2017.01.022","article-title":"The optimal monochromatic spectral computed tomographic imaging plus adaptive statistical iterative reconstruction algorithm can improve the superior mesenteric vessel image quality","volume":"89","author":"XP Yin","year":"2017","journal-title":"Eur J Radiol"},{"key":"ref4","first-page":"486","article-title":"Monochromatic Spectral Computed Tomography with Low Iodine Concentration Contrast Medium in a Rabbit VX2","volume":"23","author":"Y Zhou","year":"2016","journal-title":"Liver Model:: Investigation of Image Quality and Detection Rate. Acad Radiol"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1007\/s11547-015-0601-6","article-title":"Spectral CT imaging of intranodular hemorrhage in cases with challenging benign thyroid nodules","volume":"121","author":"M Li","year":"2016","journal-title":"Radiol Med"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1016\/j.ejrad.2011.02.063","article-title":"Improving image quality in portal venography with spectral CT imaging","volume":"81","author":"LQ Zhao","year":"2012","journal-title":"Eur J Radiol"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1007\/s12013-014-0021-6","article-title":"Spectral CT imaging in patients with Budd-Chiari syndrome: investigation of image quality","volume":"70","author":"L Su","year":"2014","journal-title":"Cell Biochem Biophys"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1148\/radiol.10092016","article-title":"Appropriate patient selection at abdominal dual-energy CT using 80 kV: relationship between patient size, image noise, and image quality","volume":"257","author":"LS Guimaraes","year":"2010","journal-title":"Radiology"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1148\/radiol.11101429","article-title":"Focal liver lesions at 3.0 T: lesion detectability and image quality with T2-weighted imaging by using conventional and dual-source parallel radiofrequency transmission","volume":"259","author":"GM Kukuk","year":"2011","journal-title":"Radiology"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.1007\/s00261-015-0387-y","article-title":"Clinical value of spectral CT in diagnosis of negative gallstones and common bile duct stones","volume":"40","author":"H Li","year":"2015","journal-title":"Abdom Imaging"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1016\/j.ejrad.2013.11.024","article-title":"Imaging of olfactory bulb and gray matter volumes in brain areas associated with olfactory function in patients with Parkinson&apos;s disease and multiple system atrophy","volume":"83","author":"S Chen","year":"2014","journal-title":"Eur J Radiol"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1007\/s00261-016-1023-1","article-title":"Metal implants on CT: comparison of iterative reconstruction algorithms for reduction of metal artifacts with single energy and spectral CT scanning in a phantom model","volume":"42","author":"J Fang","year":"2017","journal-title":"Abdom Radiol (NY)"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1186\/s12880-015-0096-6","article-title":"A pilot study using low-dose Spectral CT and ASIR (Adaptive Statistical Iterative Reconstruction) algorithm to diagnose solitary pulmonary nodules","volume":"15","author":"H Xiao","year":"2015","journal-title":"BMC Med Imaging"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"545","DOI":"10.2214\/AJR.12.9424","article-title":"Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms","volume":"200","author":"V Vardhanabhuti","year":"2013","journal-title":"AJR Am J Roentgenol"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"e938","DOI":"10.1016\/j.ejrad.2012.06.013","article-title":"Radiation dose reduction with the adaptive statistical iterative reconstruction (ASIR) technique for chest CT in children: an intra-individual comparison","volume":"81","author":"SH Lee","year":"2012","journal-title":"Eur J Radiol"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"e3227","DOI":"10.1371\/journal.pntd.0003227","article-title":"Biomarkers in Trypanosoma cruzi-infected and uninfected individuals with varying severity of cardiomyopathy in Santa Cruz, Bolivia","volume":"8","author":"EE Okamoto","year":"2014","journal-title":"PLoS Negl Trop Dis"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1148\/radiol.11101450","article-title":"Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study","volume":"259","author":"S Singh","year":"2011","journal-title":"Radiology"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.1016\/j.acra.2016.05.019","article-title":"Reducing Radiation Dose at Chest CT: Comparison Among Model-based Type Iterative Reconstruction, Hybrid Iterative Reconstruction, and Filtered Back Projection","volume":"23","author":"C de Margerie-Mellon","year":"2016","journal-title":"Acad Radiol"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.3892\/etm.2013.961","article-title":"Treatment of Budd-Chiari syndrome with inferior vena cava thrombosis","volume":"5","author":"R Wang","year":"2013","journal-title":"Exp Ther Med"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1007\/s00261-014-0240-8","article-title":"The outcomes of interventional treatment for Budd-Chiari syndrome: systematic review and meta-analysis","volume":"40","author":"F Zhang","year":"2015","journal-title":"Abdom Imaging"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0204797","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,9]],"date-time":"2020-05-09T03:17:45Z","timestamp":1588994265000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0204797"}},"subtitle":[],"editor":[{"given":"Nick","family":"Todd","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2018,10,18]]},"references-count":20,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2018,10,18]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0204797","relation":{},"ISSN":["1932-6203"],"issn-type":[{"type":"electronic","value":"1932-6203"}],"subject":[],"published":{"date-parts":[[2018,10,18]]}}}