{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T03:52:39Z","timestamp":1792900359537,"version":"4.5.0"},"reference-count":32,"publisher":"Public Library of Science (PLoS)","issue":"8","license":[{"start":{"date-parts":[[2019,8,30]],"date-time":"2019-08-30T00:00:00Z","timestamp":1567123200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0221965","type":"journal-article","created":{"date-parts":[[2019,8,30]],"date-time":"2019-08-30T17:29:03Z","timestamp":1567186143000},"page":"e0221965","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of hemodynamic effects and resuscitation outcomes between automatic simultaneous sterno-thoracic cardiopulmonary resuscitation device and LUCAS in a swine model of cardiac arrest"],"prefix":"10.1371","volume":"14","author":[{"given":"Kyoung-Chul","family":"Cha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2843-5597","authenticated-orcid":true,"given":"Hyung Il","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong Won","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gyo Jin","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5929-4291","authenticated-orcid":true,"given":"Yoon Seob","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sun Ju","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7745-3599","authenticated-orcid":true,"given":"Jun Hyuk","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4585-3181","authenticated-orcid":true,"given":"Sung","family":"Oh Hwang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2019,8,30]]},"reference":[{"key":"pone.0221965.ref001","doi-asserted-by":"crossref","first-page":"e67","DOI":"10.1161\/CIR.0000000000000558","article-title":"Heart Disease and Stroke Statistics-2018 Update: A Report From the American Heart Association","volume":"137","author":"EJ Benjamin","year":"2018","journal-title":"Circulation"},{"key":"pone.0221965.ref002","doi-asserted-by":"crossref","first-page":"S414","DOI":"10.1161\/CIR.0000000000000259","article-title":"Part 5: Adult Basic Life Support and Cardiopulmonary Resuscitation Quality: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care","volume":"132","author":"ME Kleinman","year":"2015","journal-title":"Circulation"},{"key":"pone.0221965.ref003","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.resuscitation.2015.07.016","article-title":"European Resuscitation Council Guidelines for Resuscitation 2015: Section 3. Adult advanced life support","volume":"95","author":"J Soar","year":"2015","journal-title":"Resuscitation"},{"key":"pone.0221965.ref004","doi-asserted-by":"crossref","first-page":"S17","DOI":"10.15441\/ceem.16.134","article-title":"Part 3. Advanced cardiac life support: 2015 Korean Guidelines for Cardiopulmonary Resuscitation","volume":"3","author":"MJ Lee","year":"2016","journal-title":"Clinical and experimental emergency medicine"},{"key":"pone.0221965.ref005","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/s12871-017-0351-1","article-title":"Association between cardiopulmonary resuscitation duration and one-month neurological outcomes for out-of-hospital cardiac arrest: a prospective cohort study","volume":"17","author":"M Kashiura","year":"2017","journal-title":"BMC anesthesiology"},{"key":"pone.0221965.ref006","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.resuscitation.2004.08.011","article-title":"CPREzy: an evaluation during simulated cardiac arrest on a hospital bed","volume":"64","author":"GD Perkins","year":"2005","journal-title":"Resuscitation"},{"key":"pone.0221965.ref007","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1001\/jama.293.3.299","article-title":"Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest","volume":"293","author":"L Wik","year":"2005","journal-title":"Jama"},{"key":"pone.0221965.ref008","doi-asserted-by":"crossref","first-page":"3004","DOI":"10.1161\/CIRCULATIONAHA.111.059535","article-title":"Relationship between chest compression rates and outcomes from cardiac arrest","volume":"125","author":"AH Idris","year":"2012","journal-title":"Circulation"},{"key":"pone.0221965.ref009","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1161\/CIRCULATIONAHA.109.852202","article-title":"Chest compression fraction determines survival in patients with out-of-hospital ventricular fibrillation","volume":"120","author":"J Christenson","year":"2009","journal-title":"Circulation"},{"key":"pone.0221965.ref010","first-page":"Cd007260","article-title":"Mechanical versus manual chest compressions for cardiac arrest","volume":"8","author":"PL Wang","year":"2018","journal-title":"The Cochrane database of systematic reviews"},{"key":"pone.0221965.ref011","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/j.annemergmed.2015.09.023","article-title":"Manual Cardiopulmonary Resuscitation Versus CPR Including a Mechanical Chest Compression Device in Out-of-Hospital Cardiac Arrest: A Comprehensive Meta-analysis From Randomized and Observational Studies","volume":"67","author":"JL Bonnes","year":"2016","journal-title":"Annals of emergency medicine"},{"key":"pone.0221965.ref012","doi-asserted-by":"crossref","first-page":"S436","DOI":"10.1161\/CIR.0000000000000260","article-title":"Part 6: Alternative Techniques and Ancillary Devices for Cardiopulmonary Resuscitation: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care","volume":"132","author":"SC Brooks","year":"2015","journal-title":"Circulation"},{"key":"pone.0221965.ref013","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/S0300-9572(00)00250-1","article-title":"Simultaneous sternothoracic cardiopulmonary resuscitation: a new method of cardiopulmonary resuscitation","volume":"48","author":"SO Hwang","year":"2001","journal-title":"Resuscitation"},{"key":"pone.0221965.ref014","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S0300-9572(02)00011-4","article-title":"Simultaneous sterno-thoracic cardiopulmonary resuscitation improves short-term survival rate in canine cardiac arrests","volume":"53","author":"SO Hwang","year":"2002","journal-title":"Resuscitation"},{"key":"pone.0221965.ref015","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1016\/j.jemermed.2018.04.060","article-title":"Effect of Automated Simultaneous Sternothoracic Cardiopulmonary Resuscitation Device on Hemodynamics in Out-of-Hospital Cardiac Arrest Patients","volume":"55","author":"DK Lee","year":"2018","journal-title":"The Journal of emergency medicine"},{"key":"pone.0221965.ref016","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1097\/00003246-199402000-00020","article-title":"High-dose epinephrine results in greater early mortality after resuscitation from prolonged cardiac arrest in pigs: a prospective, randomized study","volume":"22","author":"RA Berg","year":"1994","journal-title":"Critical care medicine"},{"key":"pone.0221965.ref017","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/S0196-0644(95)70076-5","article-title":"Decay in quality of closed-chest compressions over time","volume":"26","author":"D Hightower","year":"1995","journal-title":"Annals of emergency medicine"},{"key":"pone.0221965.ref018","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1007\/s00134-010-1784-x","article-title":"Effect of the AutoPulse automated band chest compression device on hemodynamics in out-of-hospital cardiac arrest resuscitation","volume":"36","author":"FX Duchateau","year":"2010","journal-title":"Intensive care medicine"},{"key":"pone.0221965.ref019","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.resuscitation.2004.12.006","article-title":"Increased cortical cerebral blood flow with LUCAS; a new device for mechanical chest compressions compared to standard external compressions during experimental cardiopulmonary resuscitation","volume":"65","author":"S Rubertsson","year":"2005","journal-title":"Resuscitation"},{"key":"pone.0221965.ref020","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1097\/MCC.0000000000000083","article-title":"High-quality cardiopulmonary resuscitation","volume":"20","author":"JP Nolan","year":"2014","journal-title":"Current opinion in critical care"},{"key":"pone.0221965.ref021","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/S0300-9572(02)00271-X","article-title":"Evaluation of LUCAS, a new device for automatic mechanical compression and active decompression resuscitation","volume":"55","author":"S Steen","year":"2002","journal-title":"Resuscitation"},{"key":"pone.0221965.ref022","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1016\/j.resuscitation.2009.08.006","article-title":"Mechanical active compression-decompression cardiopulmonary resuscitation (ACD-CPR) versus manual CPR according to pressure of end tidal carbon dioxide (P(ET)CO2) during CPR in out-of-hospital cardiac arrest (OHCA)","volume":"80","author":"C Axelsson","year":"2009","journal-title":"Resuscitation"},{"key":"pone.0221965.ref023","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1016\/j.resuscitation.2010.02.002","article-title":"Coronary blood flow and perfusion pressure during coronary angiography in patients with ongoing mechanical chest compression: a report on 6 cases","volume":"81","author":"AI Larsen","year":"2010","journal-title":"Resuscitation"},{"key":"pone.0221965.ref024","doi-asserted-by":"crossref","first-page":"2698","DOI":"10.1097\/CCM.0b013e318298ad6b","article-title":"Hemodynamic directed cardiopulmonary resuscitation improves short-term survival from ventricular fibrillation cardiac arrest","volume":"41","author":"SH Friess","year":"2013","journal-title":"Critical care medicine"},{"key":"pone.0221965.ref025","doi-asserted-by":"crossref","first-page":"e241","DOI":"10.1097\/CCM.0000000000003620","article-title":"Hemodynamic-Directed Cardiopulmonary Resuscitation Improves Neurologic Outcomes and Mitochondrial Function in the Heart and Brain","volume":"47","author":"AJ Lautz","year":"2019","journal-title":"Critical care medicine"},{"key":"pone.0221965.ref026","doi-asserted-by":"crossref","first-page":"3006","DOI":"10.1093\/eurheartj\/ehx318","article-title":"Safety of mechanical chest compression devices AutoPulse and LUCAS in cardiac arrest: a randomized clinical trial for non-inferiority","volume":"38","author":"RW Koster","year":"2017","journal-title":"European heart journal"},{"key":"pone.0221965.ref027","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1001\/jama.2013.282538","article-title":"Mechanical chest compressions and simultaneous defibrillation vs conventional cardiopulmonary resuscitation in out-of-hospital cardiac arrest: the LINC randomized trial","volume":"311","author":"S Rubertsson","year":"2014","journal-title":"Jama"},{"key":"pone.0221965.ref028","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1016\/S0140-6736(14)61886-9","article-title":"Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial","volume":"385","author":"GD Perkins","year":"2015","journal-title":"Lancet (London, England)"},{"key":"pone.0221965.ref029","doi-asserted-by":"crossref","first-page":"634","DOI":"10.5811\/westjem.2016.6.29949","article-title":"A Comparison of Chest Compression Quality Delivered During On-Scene and Ground Transport Cardiopulmonary Resuscitation","volume":"17","author":"CS Russi","year":"2016","journal-title":"The western journal of emergency medicine"},{"key":"pone.0221965.ref030","first-page":"429","article-title":"Mechanical LUCAS resuscitation is effective, reduces physical workload and improves mental performance of helicopter teams","volume":"82","author":"G Rehatschek","year":"2016","journal-title":"Minerva anestesiologica"},{"key":"pone.0221965.ref031","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s13049-016-0198-3","article-title":"Mechanical chest compressions in the coronary catheterization laboratory to facilitate coronary intervention and survival in patients requiring prolonged resuscitation efforts","volume":"24","author":"H Wagner","year":"2016","journal-title":"Scandinavian journal of trauma, resuscitation and emergency medicine"},{"key":"pone.0221965.ref032","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1253\/circj.CJ-16-0330","article-title":"Mechanical Cardiopulmonary Resuscitation In and On the Way to the Cardiac Catheterization Laboratory","volume":"80","author":"P William","year":"2016","journal-title":"Circulation journal: official journal of the Japanese Circulation Society"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/dx.plos.org\/10.1371\/journal.pone.0221965","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,8]],"date-time":"2020-05-08T20:32:40Z","timestamp":1588969960000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0221965"}},"subtitle":[],"editor":[{"given":"Theodoros","family":"Xanthos","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2019,8,30]]},"references-count":32,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2019,8,30]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0221965","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,30]]}}}