{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T09:26:13Z","timestamp":1793179573693,"version":"4.5.0"},"reference-count":32,"publisher":"Public Library of Science (PLoS)","issue":"1","license":[{"start":{"date-parts":[[2020,1,14]],"date-time":"2020-01-14T00:00:00Z","timestamp":1578960000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0227372","type":"journal-article","created":{"date-parts":[[2020,1,14]],"date-time":"2020-01-14T13:44:50Z","timestamp":1579009490000},"page":"e0227372","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":49,"title":["A smartphone-enabled wireless and batteryless implantable blood flow sensor for remote monitoring of prosthetic heart valve function"],"prefix":"10.1371","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4696-7666","authenticated-orcid":true,"given":"Bernhard","family":"Vennemann","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6062-9076","authenticated-orcid":true,"given":"Dominik","family":"Obrist","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"R\u00f6sgen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"340","published-online":{"date-parts":[[2020,1,14]]},"reference":[{"issue":"28","key":"pone.0227372.ref001","doi-asserted-by":"crossref","first-page":"2183","DOI":"10.1093\/eurheartj\/ehx141","article-title":"Mechanical versus bioprosthetic aortic valve replacement","volume":"38","author":"SJ Head","year":"2017","journal-title":"Eur Heart J"},{"issue":"7","key":"pone.0227372.ref002","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1161\/01.CIR.0000027621.26167.5E","article-title":"Aortic Valve Disease","volume":"106","author":"RA Nishimura","year":"2002","journal-title":"Circulation"},{"issue":"5","key":"pone.0227372.ref003","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/S1054-8807(03)00075-9","article-title":"The evolution of bioprosthetic heart valve design and its impact on durability","volume":"12","author":"I Vesely","year":"2003","journal-title":"Cardiovasc Pathol"},{"issue":"4","key":"pone.0227372.ref004","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/S0022-5223(94)70298-5","article-title":"Actuarial versus actual risk of porcine structural valve deterioration","volume":"108","author":"G Grunkenmeier","year":"1994","journal-title":"J Thorac Cardiovasc Surg"},{"key":"pone.0227372.ref005","unstructured":"Vilkomerson D, Chilipka T. Implantable doppler system for self-monitoring vascular grafts. IEEE Ultrasonics Symposium. 2005 461\u20135."},{"key":"pone.0227372.ref006","article-title":"Implantable ultrasound devices","author":"D Vilkomerson","year":"2008","journal-title":"Medical Imaging 2008: Ultrasonic Imaging and Signal Processing"},{"key":"pone.0227372.ref007","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.7863\/jum.2012.31.11.1795","article-title":"Development of a flexible implantable sensor for postoperative monitoring of blood flow","volume":"31","author":"JM Cannata","year":"2012","journal-title":"J Ultrasound Med"},{"key":"pone.0227372.ref008","doi-asserted-by":"crossref","unstructured":"Tang SC, Vilkomerson D, Chilipka T. Magnetically-powered implantable Doppler blood flow meter. IEEE International Ultrasonics Symposium, IUS. 2014.","DOI":"10.1109\/ULTSYM.2014.0402"},{"issue":"4S-1","key":"pone.0227372.ref009","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/01.prs.0000455398.99175.a6","article-title":"Entirely Implanted Wireless Doppler Sensor for Monitoring Venous Flow","volume":"134","author":"J Unadkat","year":"2014","journal-title":"Plast Reconstr Surg"},{"issue":"1","key":"pone.0227372.ref010","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/PRS.0000000000001372","article-title":"The Development of a Wireless Implantable Blood Flow Monitor","volume":"136","author":"JV Unadkat","year":"2015","journal-title":"Plast Reconstr Surg"},{"key":"pone.0227372.ref011","article-title":"A System for Simple Real-Time Anastomotic Failure Detection and Wireless Blood Flow Monitoring in the Lower Limbs","author":"MA Rothfuss","year":"2016","journal-title":"IEEE J Transl Eng Heal Med"},{"issue":"9","key":"pone.0227372.ref012","doi-asserted-by":"crossref","first-page":"2466","DOI":"10.1109\/TBME.2012.2203131","article-title":"An inductively powered implantable blood flow sensor microsystem for vascular grafts","volume":"59","author":"JH Cheong","year":"2012","journal-title":"IEEE Trans Biomed Eng"},{"key":"pone.0227372.ref013","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1038\/s41551-018-0336-5","article-title":"Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow","volume":"3","author":"CM Boutry","year":"2019","journal-title":"Nat Biomed Eng"},{"key":"pone.0227372.ref014","doi-asserted-by":"crossref","unstructured":"Majerus SJA, Chong H, Ariando D, Swingle C, Potkay J, Bogie K, et al. Vascular Graft Pressure-Flow Monitoring Using 3D Printed MWCNT-PDMS Strain Sensors. Proc Ann Int Conf IEEE Eng Med Biol Soc, EMBS. 2018.","DOI":"10.1109\/EMBC.2018.8512997"},{"issue":"1","key":"pone.0227372.ref015","first-page":"25","article-title":"Membrane thickness design of implantable bio-MEMS sensors for the in-situ monitoring of blood flow","volume":"18","author":"CA Steeves","year":"2007","journal-title":"J Mat Sci: Mat in Med"},{"key":"pone.0227372.ref016","doi-asserted-by":"crossref","unstructured":"Xue RF, Cheong JH, Cha HK, Liu X, Li P, Lim HJ, et al. Ultra-low-power wireless implantable blood flow sensing microsystem for vascular graft applications. Int Sym Int Cir, ISIC 2011.","DOI":"10.1109\/ISICir.2011.6131918"},{"key":"pone.0227372.ref017","doi-asserted-by":"crossref","DOI":"10.1016\/B978-0-12-089901-2.50010-7","volume-title":"Measurement of pulsatile flow and flow velocity","author":"CJ Mills","year":"1972"},{"key":"pone.0227372.ref018","first-page":"713","article-title":"Development of an implantable blood flow and pressure monitor for pulmonary hypertension","author":"SE Locke","year":"2004","journal-title":"Comput in Cardiol"},{"issue":"4","key":"pone.0227372.ref019","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1109\/TMAG.1973.1067714","article-title":"One sided fluxes\u2014a magnetic curiosity","volume":"9","author":"JC Mallinson","year":"1973","journal-title":"IEEE Trans on magnetics"},{"issue":"1","key":"pone.0227372.ref020","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0029-554X(80)90094-4","article-title":"Design of permanent multipole magnets with ori- ented rare earth cobalt material","volume":"169","author":"K Halbach","year":"1980","journal-title":"Nucl instr and methods"},{"key":"pone.0227372.ref021","first-page":"355","article-title":"Electromagnetic recording flowmeter","volume":"119","author":"A Kolin","year":"1937","journal-title":"Am J of Physiol"},{"key":"pone.0227372.ref022","first-page":"158","article-title":"Der induktionstachograph","volume":"99","author":"E Wetterer","year":"1938","journal-title":"Zeitschr fur Biol"},{"key":"pone.0227372.ref023","volume-title":"The theory of electromagnetic flow-measurement","author":"JA Shercliff","year":"1962"},{"key":"pone.0227372.ref024","volume-title":"Theory and practice of blood flow measurement","author":"JP Woodcock","year":"1975"},{"issue":"1","key":"pone.0227372.ref025","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1002\/cmr.b.20018","article-title":"Design and construction of a dipolar Halbach array with a homogeneous field from identical bar magnets: NMR Mandhalas","volume":"23B","author":"H Raich","year":"2004","journal-title":"Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering"},{"issue":"1","key":"pone.0227372.ref026","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jmr.2010.09.020","article-title":"A portable Halbach magnet that can be opened and closed without force: The NMR-CUFF","volume":"208","author":"CW Windt","year":"2011","journal-title":"J Magn Reson"},{"key":"pone.0227372.ref027","article-title":"Wireless blood flow sensing for automated diagnostics","author":"B Vennemann","year":"2019","journal-title":"ETH Research Collection"},{"issue":"9","key":"pone.0227372.ref028","doi-asserted-by":"crossref","first-page":"e0222983","DOI":"10.1371\/journal.pone.0222983","article-title":"Automated diagnosis of heart valve degradation using novelty detection algorithms and machine learning","volume":"14","author":"B Vennemann","year":"2019","journal-title":"PLoS One"},{"key":"pone.0227372.ref029","volume-title":"Materials, analysis and applications","author":"EP Furlani","year":"2001"},{"issue":"4","key":"pone.0227372.ref030","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/BF00320638","article-title":"Electrical properties of blood and its constituents: alternating current spectroscopy","volume":"46","author":"HP Schwan","year":"1983","journal-title":"Blut"},{"issue":"5","key":"pone.0227372.ref031","first-page":"259","article-title":"Permanent magnet systems for NMR tomography","volume":"40","author":"H Zijlstra","year":"1985","journal-title":"Phillips J Res"},{"issue":"5","key":"pone.0227372.ref032","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1097\/MAT.0000000000000687","article-title":"Leaflet kinematics of mechanical and bioprosthetic aortic valve prostheses","volume":"64","author":"B Vennemann","year":"2018","journal-title":"ASAIO J"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0227372","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,1,14]],"date-time":"2020-01-14T13:45:20Z","timestamp":1579009520000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0227372"}},"subtitle":[],"editor":[{"given":"Ming-Chun","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"editor"}]}],"short-title":[],"issued":{"date-parts":[[2020,1,14]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,1,14]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0227372","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,14]]}}}