{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T05:52:13Z","timestamp":1771480333713,"version":"3.50.1"},"reference-count":19,"publisher":"Public Library of Science (PLoS)","issue":"1","license":[{"start":{"date-parts":[[2020,1,27]],"date-time":"2020-01-27T00:00:00Z","timestamp":1580083200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Getinge"}],"content-domain":{"domain":["www.plosone.org"],"crossmark-restriction":false},"short-container-title":["PLoS ONE"],"DOI":"10.1371\/journal.pone.0227943","type":"journal-article","created":{"date-parts":[[2020,1,27]],"date-time":"2020-01-27T13:29:41Z","timestamp":1580131781000},"page":"e0227943","update-policy":"https:\/\/doi.org\/10.1371\/journal.pone.corrections_policy","source":"Crossref","is-referenced-by-count":8,"title":["False positive results of Bowie and Dick type test used for hospital steam sterilizer with slower come-up ramps: A case study"],"prefix":"10.1371","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1252-6344","authenticated-orcid":true,"given":"Paulo Roberto","family":"Laranjeira","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeane Aparecida Gonzalez","family":"Bronzatti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Camila Quartim de Moraes","family":"Bruna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rafael Queiroz","family":"de Souza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuko Uchikawa","family":"Graziano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Viktoriya","family":"Lusignan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"340","published-online":{"date-parts":[[2020,1,27]]},"reference":[{"key":"pone.0227943.ref001","unstructured":"Comprehensive guide to steam sterilization and sterility assurance in health care facilities. Document AAMI ST79; 2013. American National Standard website. http:\/\/www.aami.org. Published 2013. Accessed August 14, 2017."},{"key":"pone.0227943.ref002","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1046\/j.1365-2672.1999.00948.x","article-title":"A review: Taking the sterile out of sterility","volume":"87","author":"DG Allison","year":"1999","journal-title":"J Appl Microbiol"},{"key":"pone.0227943.ref003","first-page":"1","article-title":"Sterility Assurance Level (SAL): The term and its definition continues to cause confusion in the industry","volume":"14","author":"G Mosley","year":"2008","journal-title":"Pharm Microbiol Forum Newsl"},{"key":"pone.0227943.ref004","unstructured":"Sterilization\u2013Steam sterilizers\u2013Large sterilizers. Document EN 285; 2015. European Committee for Standardization website. http:\/\/www.cen.eu. Published 2015. Accessed August 14, 2017."},{"key":"pone.0227943.ref005","unstructured":"Sterilization of health care products\u2013Chemical indicators\u2013Part 1: General requirements. Document ISO 11140\u20131; 2014. International Organization for Standardization website. http:\/\/www.iso.org. Published 2014. Accessed August 14, 2017."},{"issue":"6","key":"pone.0227943.ref006","first-page":"1","article-title":"Steam sterilization principles","volume":"33","author":"M Dion","year":"2013","journal-title":"Pharm Eng"},{"key":"pone.0227943.ref007","unstructured":"Sterilization of health care products\u2013Biological Indicators\u2013Part 1: General requirements. Documento ISO 11138\u20131; 2017. International Organization for Standardization website. http:\/\/www.iso.org. Published 2017. Accessed August 14, 2017."},{"key":"pone.0227943.ref008","first-page":"395","article-title":"Effects of non-condensable gases (NCGs) on steam sterilisation processes","volume":"13","author":"U Kaiser","year":"2005","journal-title":"Zentr Steril"},{"key":"pone.0227943.ref009","first-page":"250","article-title":"Measurements of only pressure and temperature are insufficient to monitor steam sterilization processes: A case study","volume":"4","author":"JPCM Van Doornmalen","year":"2014","journal-title":"Cent Serv"},{"key":"pone.0227943.ref010","first-page":"365","article-title":"One set of requirements for steam penetration tests is enough","volume":"5","author":"S Esen","year":"2011","journal-title":"Cent Serv"},{"key":"pone.0227943.ref011","unstructured":"Sterilization of health care products\u2013Chemical indicators\u2013Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration. Document ISO 11140\u20134; 2007. International Organization for Standardization website. http:\/\/www.iso.org. Published 2007. Accessed August 14, 2017."},{"key":"pone.0227943.ref012","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.aorn.2008.06.016","article-title":"Understanding current steam sterilization recommendations and guidelines","volume":"88","author":"C Spry","year":"2008","journal-title":"AORN J"},{"key":"pone.0227943.ref013","article-title":"Guidelines for sterilization","author":"AORN","year":"2017","journal-title":"AORN Guidel Perioper Pract"},{"key":"pone.0227943.ref014","unstructured":"Sterilization of health care products\u2013Moist heat\u2013Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices. Document ISO 17665\u20131; 2006. International Organization for Standardization website. http:\/\/www.iso.org. Published 2006. Accessed August 14, 2017."},{"key":"pone.0227943.ref015","first-page":"1","article-title":"An evaluation of nine Bowie and Dick test products available in the United Kingdom","volume":"17","author":"B Kirk","year":"2012","journal-title":"Medical Device Decontamination"},{"key":"pone.0227943.ref016","first-page":"398","article-title":"Do air pockets move around?","volume":"6","author":"E Dennh\u00f6fer","year":"2015","journal-title":"Cent Serv"},{"key":"pone.0227943.ref017","unstructured":"Sterilization of health care products\u2013Moist heat\u2013Part 2: Guidance on the application of ISO 17665\u20131. Document ISO 17665\u20132; 2009. International Organization for Standardization website. http:\/\/www.iso.org. Published 2009. Accessed August 14, 2017."},{"key":"pone.0227943.ref018","doi-asserted-by":"crossref","first-page":"e29","DOI":"10.1016\/j.ajic.2016.03.001","article-title":"Troubleshooting failed sterilization loads: Process failures and wet packs\/loads","volume":"44","author":"R Seavey","year":"2016","journal-title":"Am J Infect Control"},{"key":"pone.0227943.ref019","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.ajic.2007.02.002","article-title":"Review of surface steam sterilization for validation purposes","volume":"36","author":"J Van Doornmalen","year":"2008","journal-title":"Am J Infect Control"}],"container-title":["PLOS ONE"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0227943","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,1,27]],"date-time":"2020-01-27T13:29:55Z","timestamp":1580131795000},"score":1,"resource":{"primary":{"URL":"https:\/\/dx.plos.org\/10.1371\/journal.pone.0227943"}},"subtitle":[],"editor":[{"given":"Iratxe","family":"Puebla","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2020,1,27]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,1,27]]}},"URL":"https:\/\/doi.org\/10.1371\/journal.pone.0227943","relation":{},"ISSN":["1932-6203"],"issn-type":[{"value":"1932-6203","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,27]]}}}